Literature DB >> 16255794

Right atrial migration of nephrostomy catheter.

Aderivaldo C Dias-Filho1, Guilherme A V Coaracy, Wallace Borges.   

Abstract

Percutaneous tube nephrostomy (PTN) placement is associated with bleeding complications in a small proportion of cases. We study a case of inadvertent renal vein catheterization during PTN tube change with catheter right atrial migration treated by fluoroscopically monitored catheter removal.

Entities:  

Mesh:

Year:  2005        PMID: 16255794     DOI: 10.1590/s1677-55382005000500009

Source DB:  PubMed          Journal:  Int Braz J Urol        ISSN: 1677-5538            Impact factor:   1.541


  8 in total

1.  Percutaneous silicon catheter insertion into the inferior vena cava, following percutaneous nephrostomy exchange.

Authors:  Ahmed Fouad Kotb; Ahmed Elabbady; Khaled Refaai Mohamed; Mohamed Adel Atta
Journal:  Can Urol Assoc J       Date:  2013 Jul-Aug       Impact factor: 1.862

2.  The use of endo-vascular balloon tamponade technique for the removal of a misplaced nephrostomy tube in the inferior vena cava: A case report.

Authors:  Yousof Al Zahrani; Sultan R AlHarbi; Daniele Wiseman
Journal:  Int J Surg Case Rep       Date:  2016-07-29

Review 3.  Intravenous misplacement of the nephrostomy catheter following percutaneous nephrostolithotomy: two case reports and literature review.

Authors:  Weijin Fu; Zhanbin Yang; Zhibin Xie; Haibiao Yan
Journal:  BMC Urol       Date:  2017-06-14       Impact factor: 2.264

4.  Nephrostomy catheter entering the right renal vein during an exchange procedure: A case report and literature review.

Authors:  Jun Akatsuka; Yasutomo Suzuki; Yuki Endo; Masato Yanagi; Ichiro Matsuzawa; Tsutomu Hamasaki; Go Kimura; Yukihiro Kondo
Journal:  IJU Case Rep       Date:  2021-03-11

Review 5.  Intravenous misplacement of the nephrostomy catheter following percutaneous nephrostolithotomy: a case report and literature review.

Authors:  Junbo Liu; Binglei Jiang; Juan Mao; Zhen Zeng; Lifeng Gong; Chaoyou Huang
Journal:  J Int Med Res       Date:  2020-12       Impact factor: 1.671

6.  Visualization of the renal vein filled with contrast agent may indicate the renal vein injury during percutaneous nephrolithotomy: two case reports.

Authors:  Xiao-Feng Chen; Jian-Jun Zhou; Jian-Ming Sun; Guo-Can Cao; Yi-Hua Zou; Wang-Long Deng
Journal:  BMC Urol       Date:  2021-08-06       Impact factor: 2.264

7.  Intravenous misplacement of the nephrostomy catheter following percutaneous nephrostolithotomy: two case reports.

Authors:  Eduardo Mazzucchi; Anuar Mitre; Artur Brito; Marco Arap; Claudio Murta; Miguel Srougi
Journal:  Clinics (Sao Paulo)       Date:  2009       Impact factor: 2.365

8.  Inadvertent insertion of nephrostomy tube into the renal vein following percutaneous nephrolithotomy: A case report and literature review.

Authors:  Guangju Ge; Zhenghui Wang; Mingchao Wang; Gonghui Li; Zuhao Xu; Yukun Wang; Shawpong Wan
Journal:  Asian J Urol       Date:  2018-06-21
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.