Literature DB >> 1625560

Factors influencing the accuracy and precision of velocity-encoded phase imaging.

M H Buonocore1, H Bogren.   

Abstract

Velocity-encoded phase contrast imaging is being used increasingly in clinical imaging for quantization of blood flow. In this study, the accuracy and precision of ascending aorta flow measurements were found to depend on several subtle aspects of the scan prescription and image analysis. While the usual scan parameters such as TR, TE, and flip angle gave incremental changes in the flow measurements, four additional factors that had a much greater effect on the measurements were identified. These factors were (1) the zero velocity (background) pixel value, (2) the size and shape of the vessel region of interest, (3) the maximum velocity encoded in diastole, and (4) the temporal resolution. Statistical analysis was done on a total of 48 scans on nine normal subjects to confirm the significance of the measured differences using the various choices for each of these factors. These factors must be considered if accurate and precise measurements of blood flow are desired. Estimates of accuracy and precision suggest that quantitative flow measurements from velocity-encoded MR imaging can be clinically useful.

Mesh:

Year:  1992        PMID: 1625560     DOI: 10.1002/mrm.1910260115

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  11 in total

1.  Microscopic spin tagging (MiST) for flow imaging.

Authors:  Silvia Olt; Peter Schmitt; Florian Fidler; Axel Haase; Peter M Jakob
Journal:  MAGMA       Date:  2002-11       Impact factor: 2.310

Review 2.  Four-dimensional flow magnetic resonance imaging in cirrhosis.

Authors:  Zoran Stankovic
Journal:  World J Gastroenterol       Date:  2016-01-07       Impact factor: 5.742

3.  Mitral regurgitation quantification by cardiovascular magnetic resonance: a comparison of indirect quantification methods.

Authors:  Christian L Polte; Odd Bech-Hanssen; Åse A Johnsson; Sinsia A Gao; Kerstin M Lagerstrand
Journal:  Int J Cardiovasc Imaging       Date:  2015-05-23       Impact factor: 2.357

4.  Evaluation of valvular insufficiency and shunts with parallel-imaging compressed-sensing 4D phase-contrast MR imaging with stereoscopic 3D velocity-fusion volume-rendered visualization.

Authors:  Albert Hsiao; Michael Lustig; Marcus T Alley; Mark J Murphy; Shreyas S Vasanawala
Journal:  Radiology       Date:  2012-08-24       Impact factor: 11.105

5.  Reproducibility study of four-dimensional flow MRI of arterial and portal venous liver hemodynamics: influence of spatio-temporal resolution.

Authors:  Zoran Stankovic; Bernd Jung; Jeremy Collins; Maximilian F Russe; James Carr; Wulf Euringer; Lena Stehlin; Zoltan Csatari; Peter C Strohm; Mathias Langer; Michael Markl
Journal:  Magn Reson Med       Date:  2013-09-09       Impact factor: 4.668

6.  Rapid pediatric cardiac assessment of flow and ventricular volume with compressed sensing parallel imaging volumetric cine phase-contrast MRI.

Authors:  Albert Hsiao; Michael Lustig; Marcus T Alley; Mark Murphy; Frandics P Chan; Robert J Herfkens; Shreyas S Vasanawala
Journal:  AJR Am J Roentgenol       Date:  2012-03       Impact factor: 3.959

7.  MR Quantification of Flow in Children with Vein of Galen Malformations.

Authors:  K J Poskitt; T Marotta; G Culham; S Xiang
Journal:  Interv Neuroradiol       Date:  2001-10-15       Impact factor: 1.610

8.  MR Quantification of Flow in Children with Vascular Malformations.

Authors:  K J Poskitt; T Marotta; C Haw; D Cochrane; P Steinbok
Journal:  Interv Neuroradiol       Date:  2001-10-15       Impact factor: 1.610

9.  Assessing test-retest reliability of phase contrast MRI for measuring cerebrospinal fluid and cerebral blood flow dynamics.

Authors:  Ashwin R Sakhare; Giuseppe Barisano; Judy Pa
Journal:  Magn Reson Med       Date:  2019-04-25       Impact factor: 3.737

10.  On the optimal temporal resolution for phase contrast cardiovascular magnetic resonance imaging: establishment of baseline values.

Authors:  Francesco Santini; Michele Pansini; Maja Hrabak-Paar; Denise Yates; Thomas H Langenickel; Jens Bremerich; Oliver Bieri; Tilman Schubert
Journal:  J Cardiovasc Magn Reson       Date:  2020-10-05       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.