Literature DB >> 16253905

The impact of respiration on left atrial and pulmonary venous anatomy: implications for image-guided intervention.

Peter A Noseworthy1, Zachary J Malchano, Jameel Ahmed, Godtfred Holmvang, Jeremy N Ruskin, Vivek Y Reddy.   

Abstract

BACKGROUND: Image-guided intervention using pre-acquired CT/MR 3-dimensional images is an emerging strategy for atrial fibrillation (AF) ablation but may be limited by its use of static images to depict dynamic physiology. The effect of biologic factors such as respiration on the left atrial-pulmonary venous (LA-PV) anatomy is not well understood but is likely to have important implications. Conventional CT/MR imaging is performed during an inspiratory breath-hold, while electroanatomical mapping (EAM) during "quiet" breathing approximates an expiratory breath-hold. This study examined the effects of respiration on LA-PV anatomy and the error introduced by respiration on the integration of EAM with 3D MR imaging.
METHODS: Pre-procedural MRI angiography was performed at both end-expiration (EXP) and end-inspiration (INSP) in 20 patients undergoing AF catheter ablation. 3D INSP and EXP surface reconstructions of the LA-PVs were compared. In selected pts, EAM data acquired during the ablation procedure (n=7) were integrated with the 3D MRI datasets.
RESULTS: Qualitative assessment of the INSP and EXP 3D images revealed splaying of the PVs and reduction in PV caliber of the right-sided PVs during held inspiration. After aligning these two datasets, the average surface-to-surface distance calculated by region ranged from 1.99mm (right middle PV) to 3.79mm (left superior PV). Registration of the EAM to the MRI models was better for the EXP dataset (2.30+/-0.73mm) than the INSP dataset (3.03+/-0.57mm; p=0.004).
CONCLUSION: There are significant changes in LA-PV anatomy with respiration. MR images acquired during standard held inspiration may introduce unnecessary errors in registration during image-guided intervention.

Entities:  

Mesh:

Year:  2005        PMID: 16253905     DOI: 10.1016/j.hrthm.2005.08.008

Source DB:  PubMed          Journal:  Heart Rhythm        ISSN: 1547-5271            Impact factor:   6.343


  30 in total

Review 1.  Fusion of imaging technologies: how, when, and for whom?

Authors:  Ashul Govil; Hugh Calkins; David D Spragg
Journal:  J Interv Card Electrophysiol       Date:  2011-10-01       Impact factor: 1.900

2.  Respiratory gating algorithm helps to reconstruct more accurate electroanatomical maps during atrial fibrillation ablation performed under spontaneous respiration.

Authors:  Gábor Széplaki; László Gellér; Emin Evren Özcan; Tamás Tahin; Orsolya Mária Kovács; Nóra Parázs; Júlia Karády; Pál Maurovich-Horvat; Szabolcs Szilágyi; István Osztheimer; Attila Tóth; Béla Merkely
Journal:  J Interv Card Electrophysiol       Date:  2016-01-27       Impact factor: 1.900

3.  The seamless integration of three-dimensional rotational angiography images into electroanatomical mapping systems to guide catheter ablation of atrial fibrillation.

Authors:  Satoshi Fujita; Eitaro Fujii; Yoshihiko Kagawa; Katsuhiro Inoue; Tsuyoshi Yamada; Masaaki Ito
Journal:  Heart Vessels       Date:  2018-05-07       Impact factor: 2.037

4.  Experience with CartoSound for arrhythmia ablation in pediatric and congenital heart disease patients.

Authors:  Adam C Kean; Sarah K Gelehrter; Ira Shetty; Macdonald Dick; David J Bradley
Journal:  J Interv Card Electrophysiol       Date:  2010-09-28       Impact factor: 1.900

5.  Factors affecting error in integration of electroanatomic mapping with CT and MR imaging during catheter ablation of atrial fibrillation.

Authors:  E Kevin Heist; Jianping Chevalier; Godtfred Holmvang; Jagmeet P Singh; Patrick T Ellinor; David J Milan; Andre D'Avila; Theofanie Mela; Jeremy N Ruskin; Moussa Mansour
Journal:  J Interv Card Electrophysiol       Date:  2007-01-25       Impact factor: 1.900

6.  Technology preview: X-ray fused with magnetic resonance during invasive cardiovascular procedures.

Authors:  Luis F Gutiérrez; Ranil de Silva; Cengizhan Ozturk; Merdim Sonmez; Annette M Stine; Amish N Raval; Venkatesh K Raman; Vandana Sachdev; Ronnier J Aviles; Myron A Waclawiw; Elliot R McVeigh; Robert J Lederman
Journal:  Catheter Cardiovasc Interv       Date:  2007-11-15       Impact factor: 2.692

7.  Accuracy of left atrial anatomical maps acquired with a multielectrode catheter during catheter ablation for atrial fibrillation.

Authors:  Jacob S Koruth; E Kevin Heist; Stephan Danik; Conor D Barrett; Rajesh Kabra; Dan Blendea; Jeremy Ruskin; Moussa Mansour
Journal:  J Interv Card Electrophysiol       Date:  2011-04-19       Impact factor: 1.900

8.  Respiratory compensation improves the accuracy of electroanatomic mapping of the left atrium and pulmonary veins during atrial fibrillation ablation.

Authors:  Roy Beinart; Rajesh Kabra; Kevin E Heist; Dan Blendea; Conor D Barrett; Stephan B Danik; Ryan Collins; Jeremy N Ruskin; Moussa Mansour
Journal:  J Interv Card Electrophysiol       Date:  2011-05-24       Impact factor: 1.900

9.  Impact of respiration gating on image integration guided atrial fibrillation ablation.

Authors:  Emin Evren Özcan; Gabor Szeplaki; Tamas Tahin; Istvan Osztheimer; Szabolcs Szilagyi; Astrid Apor; Pal Maurovich Horvath; Hajnalka Vago; Béla Merkely; Laszlo Geller
Journal:  Clin Res Cardiol       Date:  2014-05-07       Impact factor: 5.460

10.  Evaluation of 3D guided electroanatomic mapping for ablation of atrial fibrillation in reference to CT-Scan image integration.

Authors:  Christian de Chillou; Marius Andronache; Ahmed Abdelaal; Yves Ernst; Isabelle Magnin-Poull; Mohamed Magdi; Ning Zhang; Samuel Tissier; Damien Mandry; Cécile Barbary; Denis Régent; Etienne Aliot
Journal:  J Interv Card Electrophysiol       Date:  2008-09-27       Impact factor: 1.900

View more