Literature DB >> 1624744

Influence of emergency physician's tying technique on knot security.

E K Batra1, D A Franz, M A Towler, G T Rodeheaver, J G Thacker, C A Zimmer, R F Edlich.   

Abstract

The purpose of this study was to determine the influence of emergency physician's tying technique on knot security using 2-0 and 4-0 monofilament and multifilament nylon sutures. Using an Instron Tensile Tester and a portable tensiometer, knot security was achieved with these sutures using four-throw square knots (1 = 1 = 1 = 1). After didactic and psychomotor skill training, medical students were taught to construct the four-throw square knot using either a two-hand tie or an instrument tie. Using the portable tensiometer, their knot tying techniques were judged to be superior to those used by emergency physicians. The emergency physician's faulty technique can easily be corrected by didactic information and psychomotor skill training.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1624744     DOI: 10.1016/0736-4679(92)90338-t

Source DB:  PubMed          Journal:  J Emerg Med        ISSN: 0736-4679            Impact factor:   1.484


  4 in total

1.  Effects of using a surgical clamp to hold tension while tying knots with commonly used orthopedic sutures.

Authors:  Leslie J Bisson; Andrew D Sobel; David Godfrey
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-09-16       Impact factor: 4.342

2.  The Effect of Different Combinations of Three Stacked Half-Hitches and Suture Materials on an Arthroscopic Knot in a Dry or Wet Environment.

Authors:  Alexander Cm Chong; Jordan L Ochs; Rosalee E Zackula; Lisa N MacFadden; Daniel J Prohaska
Journal:  Iowa Orthop J       Date:  2018

3.  Comparative study of knot performance and ease of manipulation of monofilament and braided sutures for arthroscopic applications.

Authors:  Xiaoli Li; Martin King; Peter MacDonald
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-04-30       Impact factor: 4.342

4.  Validation of Different Combination of Three Reversing Half-Hitches Alternating Posts (RHAPs) Effects on Arthroscopic Knot Integrity.

Authors:  Alexander Cm Chong; Daniel J Prohaska; Brian P Bye
Journal:  Kans J Med       Date:  2017-05-15
  4 in total