Comparative study of knot performance and ease of manipulation of monofilament and braided sutures for arthroscopic applications.

Xiaoli Li1, Martin King, Peter MacDonald.   

Abstract

Our aim was to identify alternative suture materials that might provide superior knot performance and equivalent ease of manipulation by means of an in vitro experimental study. Although used widely for arthroscopic shoulder stabilisation, absorbable poly( p-dioxanone) (PDS) monofilament sutures can lead to dehiscence and clinical failure due to knot slippage and/or loop elongation at low applied loads. With the objective of identifying alternative suture materials that might provide superior knot performance and equivalent ease of manipulation, an in vitro experiment was undertaken in which both Duncan and Snyder knotted loops were tied from four different suture materials using an arthroscopic knot pusher (Surgeon's 6th Finger) and a wooden practice box (Arthrex). Three monofilament sutures, made from polypropylene (PROLENE), poly(glycolidetrimethylenecarbonate-co-dioxanone) (Biosyn) and PDS, and one braided polyester suture (SURGIDAC) were tested. Ease of manipulation was evaluated by measuring the time required to tie the knots, and the knot performance was assessed in terms of loop elongation and loop holding capacity by performing cyclic fatigue testing of the loops while they were immersed in saline on an INSTRON mechanical tester. The PROLENE and SURGIDAC sutures showed improvements in loop elongation and loop holding capacity over PDS, with the Snyder knots being consistently superior to Duncan knots. BIOSYN gave no improvement over PDS. Difficulties were encountered in advancing half-hitch throws of the braided SURGIDAC suture down the cannula, which resulted in longer knotting times. In conclusion, both the polypropylene and polyester sutures gave superior knot performance to PDS, but only the polypropylene gave equivalent ease of manipulation. As a result there may be clinical advantages in replacing PDS with monofilament polypropylene or braided polyester sutures for certain arthroscopic procedures.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15118814     DOI: 10.1007/s00167-004-0503-y

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  7 in total

1.  Technical considerations in manual and instrument tying techniques.

Authors:  J D James; M M Wu; E K Batra; G T Rodeheaver; R F Edlich
Journal:  J Emerg Med       Date:  1992 Jul-Aug       Impact factor: 1.484

2.  Influence of emergency physician's tying technique on knot security.

Authors:  E K Batra; D A Franz; M A Towler; G T Rodeheaver; J G Thacker; C A Zimmer; R F Edlich
Journal:  J Emerg Med       Date:  1992 May-Jun       Impact factor: 1.484

3.  Loop security as a determinant of tissue fixation security.

Authors:  S S Burkhart; M A Wirth; M Simonick; D Salem; D Lanctot; K Athanasiou
Journal:  Arthroscopy       Date:  1998-10       Impact factor: 4.772

4.  Mechanical performance of square knots and sliding knots in surgery: comparative study.

Authors:  E J van Rijssel; J B Trimbos; M H Booster
Journal:  Am J Obstet Gynecol       Date:  1990-01       Impact factor: 8.661

5.  Elongation of arthroscopically tied knots.

Authors:  D K Mishra; W D Cannon; D J Lucas; J P Belzer
Journal:  Am J Sports Med       Date:  1997 Jan-Feb       Impact factor: 6.202

6.  Knot security and synthetic suture materials.

Authors:  D J Magilligan; J A DeWeese
Journal:  Am J Surg       Date:  1974-03       Impact factor: 2.565

7.  Optimizing arthroscopic knots.

Authors:  T D Loutzenheiser; D T Harryman; S W Yung; M P France; J A Sidles
Journal:  Arthroscopy       Date:  1995-04       Impact factor: 4.772

  7 in total
  3 in total

1.  An in vitro analysis of the mechanical properties of 16 arthroscopic knots.

Authors:  Keith M Baumgarten; Michael D Brodt; Matthew J Silva; Rick W Wright
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-08-22       Impact factor: 4.342

2.  Mechanical testing of different knot types using high-performance suture material.

Authors:  M H Baums; Ch Sachs; T Kostuj; K Schmidt-Horlohé; W Schultz; H-M Klinger
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-10-13       Impact factor: 4.342

3.  Nonabsorbable-suture-induced osteomyelitis: a case report and review of the literature.

Authors:  Cheng Hong Yeo; Nick C Russell; Tom Sharpe
Journal:  Case Rep Orthop       Date:  2012-10-09
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.