Literature DB >> 16245602

A system for simultaneously measuring contact force, ultrasound, and position information for use in force-based correction of freehand scanning.

Michael R Burcher1, J Alison Noble, Lianghao Han, Mark Gooding.   

Abstract

During freehand ultrasound imaging, the sonographer places the ultrasound probe on the patient's skin. This paper describes a system that simultaneously records the position of the probe, the contact force between the probe and skin, and the ultrasound image. The system consists of an ultrasound machine, a probe, a force sensor, an optical localizer, and a host computer. Two new calibration methods are demonstrated: a temporal calibration to determine the time delay between force and position measurements, and a gravitational calibration to remove the effect of gravity on the recorded force. Measurements made with the system showed good agreement with those obtained from a standard materials testing machine. The system's uses include three-dimensional (3-D) ultrasound imaging, force-based deformation correction of ultrasound images, and indentation testing.

Entities:  

Mesh:

Year:  2005        PMID: 16245602     DOI: 10.1109/tuffc.2005.1509791

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  4 in total

Review 1.  Assistive technology for ultrasound-guided central venous catheter placement.

Authors:  Mohammad Ikhsan; Kok Kiong Tan; Andi Sudjana Putra
Journal:  J Med Ultrason (2001)       Date:  2017-04-19       Impact factor: 1.314

2.  Design, Development and Validation of a Knee Brace to Standardize the US Imaging Evaluation of Knee Osteoarthritis.

Authors:  A Sorriento; A Cafarelli; P Spinnato; A Russo; G Lisignoli; F Rabusseau; P Cabras; E Dumont; L Ricotti
Journal:  IEEE J Transl Eng Health Med       Date:  2021-12-22

Review 3.  Biomarkers and Detection Platforms for Human Health and Performance Monitoring: A Review.

Authors:  Daniel Sim; Michael C Brothers; Joseph M Slocik; Ahmad E Islam; Benji Maruyama; Claude C Grigsby; Rajesh R Naik; Steve S Kim
Journal:  Adv Sci (Weinh)       Date:  2022-01-12       Impact factor: 16.806

4.  Interrater reliability of quantitative ultrasound using force feedback among examiners with varied levels of experience.

Authors:  Michael O Harris-Love; Catheeja Ismail; Reza Monfaredi; Haniel J Hernandez; Donte Pennington; Paula Woletz; Valerie McIntosh; Bernadette Adams; Marc R Blackman
Journal:  PeerJ       Date:  2016-06-21       Impact factor: 2.984

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.