A dosimetric evaluation of water equivalent phantoms for kilovoltage x-ray beams.

R Hill1, L Holloway, C Baldock.   

Abstract

Solid phantoms are widely used in radiation therapy for both relative and reference dosimetry. Two water equivalent phantoms, RMI-457 Solid Water and Plastic Water, were evaluated for use in kilovoltage x-ray dosimetry in the energy range from 75 to 300 kVp. Relative and reference dosimetry measurements were performed in the solid phantoms and compared with water. The results indicate that RMI-457 Solid Water could be used for output factor determination for all energies tested and the measurement of percentage depth doses for the 300 kVp x-ray beam, with data agreeing to within 1%, compared to the same measurements in water. For the same criteria, Plastic Water could only be used for output factor determination of the 300 kVp x-ray beam. The superior agreement of the calculated mass-energy absorption coefficients for Solid Water and water, as compared to Plastic Water and water was consistent with the experimental results. Reference dosimetry is not recommended with the solid phantoms for the energies studied due to the lack of published correction factors. It is recommended that any solid phantom be tested by comparison with water in the same manner before being used for the dosimetry of kilovoltage x-ray beams.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16237233     DOI: 10.1088/0031-9155/50/21/N06

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  9 in total

1.  Acceptance, commissioning and clinical use of the WOmed T-200 kilovoltage X-ray therapy unit.

Authors:  Maria M Aspradakis; Paolo Zucchetti
Journal:  Br J Radiol       Date:  2015-07-30       Impact factor: 3.039

2.  Use of calculations to validate beam quality and relative dose measurements for a kilovoltage X-ray therapy unit.

Authors:  B J Healy; R F Hill
Journal:  Phys Eng Sci Med       Date:  2022-04-05

3.  Characterization of an orthovoltage biological irradiator used for radiobiological research.

Authors:  Rezvan Azimi; Parham Alaei; Emiliano Spezi; Susanta K Hui
Journal:  J Radiat Res       Date:  2015-02-17       Impact factor: 2.724

4.  Commissioning kilovoltage cone-beam CT beams in a radiation therapy treatment planning system.

Authors:  Parham Alaei; Emiliano Spezi
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

5.  Real-time, ray casting-based scatter dose estimation for c-arm x-ray system.

Authors:  Zaid Alnewaini; Eric Langer; Philipp Schaber; Matthias David; Dominik Kretz; Volker Steil; Jürgen Hesser
Journal:  J Appl Clin Med Phys       Date:  2017-01-24       Impact factor: 2.102

Review 6.  Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D.

Authors:  Yves De Deene
Journal:  Gels       Date:  2022-09-19

7.  Solid water phantom heat conduction: Heating and cooling rates.

Authors:  Martin J Butson; Tsang Cheung; Peter K N Yu
Journal:  J Med Phys       Date:  2008-01

8.  Dosimetric evaluation of Plastic Water Diagnostic-Therapy.

Authors:  Ramani Ramaseshan; Kirpal Kohli; Fred Cao; Robert K Heaton
Journal:  J Appl Clin Med Phys       Date:  2008-04-29       Impact factor: 2.102

9.  Comparison of an anthropomorphic PRESAGE® dosimeter and radiochromic film with a commercial radiation treatment planning system for breast IMRT: a feasibility study.

Authors:  Khalid Iqbal; Kent A Gifford; Geoffrey Ibbott; Ryan L Grant; Saeed Buzdar
Journal:  J Appl Clin Med Phys       Date:  2014-01-06       Impact factor: 2.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.