Literature DB >> 16235006

High mortality rate after extubation failure after pediatric cardiac surgery.

A D J Ten Harkel1, M M J van der Vorst, M G Hazekamp, J Ottenkamp.   

Abstract

The objective of this study was to evaluate the different causes of extubation failure and the consequent mortality rates in a pediatric population after cardiac surgery. We studied 184 consecutive patients with a median age of 9 months (range, 0-165). In 158 patients, extubation was successful (group A). Nine patients were reintubated for upper airway obstruction and finally extubated successfully (group B). Seventeen patients were reintubated for cardiorespiratory failure, finally leading to death in 11 of 17 patients (65%) (group C). Group B patients were younger and had a longer intubation period compared to group A patients. Group C patients had more reoperations (30% vs 4% in group A patients, p < 0.001), a lower PaO2 on admission at the intensive care unit as well as just prior to extubation, a lower base deficit before extubation, and needed more inotropic support during their stay in the intensive care unit. We conclude that extubation failure after pediatric cardiac surgery due to cardiorespiratory failure is a bad prognostic sign. Patients with high inotropic support and a low PaO2 prior to extubation are especially at risk and probably need careful evaluation before final extubation.

Entities:  

Mesh:

Year:  2005        PMID: 16235006     DOI: 10.1007/s00246-005-0906-7

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  20 in total

1.  Calibration of the paediatric index of mortality in UK paediatric intensive care units.

Authors:  G A Pearson; J Stickley; F Shann
Journal:  Arch Dis Child       Date:  2001-02       Impact factor: 3.791

2.  Delay of extubation in neonates and children after cardiac surgery: impact of ventilator-associated pneumonia.

Authors:  J E Fischer; P Allen; S Fanconi
Journal:  Intensive Care Med       Date:  2000-07       Impact factor: 17.440

3.  Effect of failed extubation on the outcome of mechanical ventilation.

Authors:  S K Epstein; R L Ciubotaru; J B Wong
Journal:  Chest       Date:  1997-07       Impact factor: 9.410

4.  Early extubation after cardiac operations in neonates and young infants.

Authors:  J S Heinle; L K Diaz; L S Fox
Journal:  J Thorac Cardiovasc Surg       Date:  1997-09       Impact factor: 5.209

5.  Extubation failure in a large pediatric ICU population.

Authors:  S Edmunds; I Weiss; R Harrison
Journal:  Chest       Date:  2001-03       Impact factor: 9.410

6.  Serial stent implantation to relieve in-stent stenosis in obstructed total anomalous pulmonary venous return.

Authors:  Ina Michel-Behnke; Monika Luedemann; Karl-Juergen Hagel; Dietmar Schranz
Journal:  Pediatr Cardiol       Date:  2002-02-19       Impact factor: 1.655

7.  Oxygen transport in critically ill infants after congenital heart operations.

Authors:  A F Rossi; H S Seiden; R P Gross; R B Griepp
Journal:  Ann Thorac Surg       Date:  1999-03       Impact factor: 4.330

Review 8.  Consensus-based method for risk adjustment for surgery for congenital heart disease.

Authors:  Kathy J Jenkins; Kimberlee Gauvreau; Jane W Newburger; Thomas L Spray; James H Moller; Lisa I Iezzoni
Journal:  J Thorac Cardiovasc Surg       Date:  2002-01       Impact factor: 5.209

9.  Perioperative predictors of extubation failure and the effect on clinical outcome after cardiac surgery.

Authors:  M Y Rady; T Ryan
Journal:  Crit Care Med       Date:  1999-02       Impact factor: 7.598

10.  Failed extubation after cardiac surgery in young children: Prevalence, pathogenesis, and risk factors.

Authors:  A. Marc Harrison; Amy C. Cox; Steve Davis; Marion Piedmonte; Jonathan J. Drummond-Webb; Roger B. B. Mee
Journal:  Pediatr Crit Care Med       Date:  2002-04       Impact factor: 3.624

View more
  10 in total

1.  Predictors of Early Extubation After Pediatric Cardiac Surgery: A Single-Center Prospective Observational Study.

Authors:  Çağlar Ödek; Tanıl Kendirli; Tayfun Uçar; Ayhan Yaman; Ercan Tutar; Zeynep Eyileten; Mehmet Taşar; Mehmet Ramoğlu; Can Ateş; Adnan Uysalel; Erdal İnce; Semra Atalay
Journal:  Pediatr Cardiol       Date:  2016-06-06       Impact factor: 1.655

2.  The Influence of Fluid Overload on the Length of Mechanical Ventilation in Pediatric Congenital Heart Surgery.

Authors:  Tatiana Z A L Sampaio; Katie O'Hearn; Deepti Reddy; Kusum Menon
Journal:  Pediatr Cardiol       Date:  2015-06-30       Impact factor: 1.655

3.  Variation in extubation failure rates after neonatal congenital heart surgery across Pediatric Cardiac Critical Care Consortium hospitals.

Authors:  Brian D Benneyworth; Christopher W Mastropietro; Eric M Graham; Darren Klugman; John M Costello; Wenying Zhang; Michael Gaies
Journal:  J Thorac Cardiovasc Surg       Date:  2017-02-04       Impact factor: 5.209

4.  The endotracheal tube air leak test does not predict extubation outcome in critically ill pediatric patients.

Authors:  Angela T Wratney; Daniel Kelly Benjamin; Anthony D Slonim; James He; Donna S Hamel; Ira M Cheifetz
Journal:  Pediatr Crit Care Med       Date:  2008-09       Impact factor: 3.624

5.  Higher pulmonary dead space may predict prolonged mechanical ventilation after cardiac surgery.

Authors:  Thida Ong; Regan B Stuart-Killion; Brian M Daniel; Laura B Presnell; Hanjing Zhuo; Michael A Matthay; Kathleen D Liu
Journal:  Pediatr Pulmonol       Date:  2009-05

Review 6.  Defining sedation-related adverse events in the pediatric intensive care unit.

Authors:  Mary Jo C Grant; Michele C Balas; Martha A Q Curley
Journal:  Heart Lung       Date:  2013 May-Jun       Impact factor: 2.210

7.  Neurally Adjusted Ventilatory Assist Is Associated with Greater Initial Extubation Success in Postoperative Congenital Heart Disease Patients when Compared to Conventional Mechanical Ventilation.

Authors:  Shawn Berry Sood; Nasir Mushtaq; Kellie Brown; Vanette Littlefield; Roger Phillip Barton
Journal:  J Pediatr Intensive Care       Date:  2018-02-05

8.  Risk factors for post-extubation stridor in children: the role of orotracheal cannula.

Authors:  Milena Siciliano Nascimento; Cristiane Prado; Eduardo Juan Troster; Naiana Valério; Marcela Batan Alith; João Fernando Lourenço de Almeida
Journal:  Einstein (Sao Paulo)       Date:  2015-06-09

9.  Complex effects of high-flow nasal cannula therapy on hemodynamics in the pediatric patient after cardiac surgery.

Authors:  Yu Inata; Muneyuki Takeuchi
Journal:  J Intensive Care       Date:  2017-05-30

Review 10.  Developing an Extubation strategy for the difficult pediatric airway-Who, when, why, where, and how?

Authors:  Andrew D Weatherall; Renee D Burton; Michael G Cooper; Susan R Humphreys
Journal:  Paediatr Anaesth       Date:  2022-02-25       Impact factor: 2.129

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.