Literature DB >> 16234960

Microfluidic device as a new platform for immunofluorescent detection of viruses.

Wen-Tso Liu1, Liang Zhu, Qi-Wei Qin, Qing Zhang, Hanhua Feng, Simon Ang.   

Abstract

A bead-based microfluidic device was developed and demonstrated to achieve rapid and sensitive enzyme-linked immunosorbent assay (ELISA) with quantum dots as the labeling fluorophore for virus detection. In comparison to standard ELISA performed on the same virus, the minimal detectable concentration of the target virus was improved from 360 to 22 ng mL-1, the detection time was shortened from >3.25 h to <30 min, and the amount of antibody consumed was reduced by a factor of 14.3.

Entities:  

Mesh:

Year:  2005        PMID: 16234960     DOI: 10.1039/b509086e

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  9 in total

Review 1.  Tackling HIV through robust diagnostics in the developing world: current status and future opportunities.

Authors:  Darash Desai; Grace Wu; Muhammad H Zaman
Journal:  Lab Chip       Date:  2010-12-01       Impact factor: 6.799

2.  Quantum dot-based HIV capture and imaging in a microfluidic channel.

Authors:  Yun-Gon Kim; Sangjun Moon; Daniel R Kuritzkes; Utkan Demirci
Journal:  Biosens Bioelectron       Date:  2009-06-18       Impact factor: 10.618

Review 3.  Advances in developing HIV-1 viral load assays for resource-limited settings.

Authors:  ShuQi Wang; Feng Xu; Utkan Demirci
Journal:  Biotechnol Adv       Date:  2010-07-01       Impact factor: 14.227

4.  Shadow masking for nanomaterial-based biosensors incorporated with a microfluidic device.

Authors:  Jiyong Huang; Innam Lee; Xiliang Luo; Xinyan Tracy Cui; Minhee Yun
Journal:  Biomed Microdevices       Date:  2013-06       Impact factor: 2.838

5.  A microfluidic device for multiplexed protein detection in nano-liter volumes.

Authors:  Alan H Diercks; Adrian Ozinsky; Carl L Hansen; James M Spotts; David J Rodriguez; Alan Aderem
Journal:  Anal Biochem       Date:  2008-12-24       Impact factor: 3.365

6.  Reciprocating-flowing on-a-chip enables ultra-fast immunobinding for multiplexed rapid ELISA detection of SARS-CoV-2 antibody.

Authors:  Yiren Liu; Yayin Tan; Quanying Fu; Maoren Lin; Jinxu He; Suhua He; Mei Yang; Shoudeng Chen; Jianhua Zhou
Journal:  Biosens Bioelectron       Date:  2020-12-29       Impact factor: 10.618

7.  Vertically sheathing laminar flow-based immunoassay using simultaneous diffusion-driven immune reactions.

Authors:  Amanzhol Kurmashev; Seyong Kwon; Je-Kyun Park; Joo H Kang
Journal:  RSC Adv       Date:  2019-07-31       Impact factor: 3.361

Review 8.  Emerging molecular assays for detection and characterization of respiratory viruses.

Authors:  Wenjuan Wu; Yi-Wei Tang
Journal:  Clin Lab Med       Date:  2009-12       Impact factor: 1.935

Review 9.  Microfluidic devices for detection of RNA viruses.

Authors:  Arefeh Basiri; Arash Heidari; Melina Farshbaf Nadi; Mohammad Taha Pahlevan Fallahy; Sasan Salehi Nezamabadi; Mohammadreza Sedighi; Amene Saghazadeh; Nima Rezaei
Journal:  Rev Med Virol       Date:  2020-08-26       Impact factor: 11.043

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.