Literature DB >> 16232080

Impact of standardized calibration on the inter-assay variation of 14 automated assays for the measurement of creatinine in human serum.

Sophie Séronie-Vivien1, Marie-Madeleine Galteau, Marie-Christine Carlier, Aoumeur Hadj-Aissa, Anne-Marie Hanser, Bernadette Hym, Alain Marchal, Odile Michotey, Claire Pouteil-Noble, Michel Sternberg, Armand Perret-Liaudet.   

Abstract

PURPOSE: The aim of our study was to measure the inter-assay variation and accuracy of serum creatinine assays and to assess the effect of standardized calibration procedures on this variability.
METHODS: We analyzed 30 human sera and three reference materials, using 17 creatinine assays (12 colorimetric, 4 enzymatic and 1 HPLC). We compared two standardized calibration procedures, using either a reference material or secondary standards, to that recommended by the manufacturers.
RESULTS: For assays calibrated according to the manufacturers' recommendations, the median inter-assay coefficient of variation (CV) was 14.2% for 20 low samples (45-150 microM), and 7.7% for 10 high samples (250-350 microM). The CV was significantly influenced by the calibration procedure, but none of the standardized calibration procedures significantly improved the inter-assay variability. However, a significant decrease in CV was noted within each type of assay method (colorimetric or enzymatic) when the standardized calibration used standards of level(s) close to the concentrations to be measured. Only the compensated Jaffe technique and the amido-hydrolase assay showed bias of less than 10%.
CONCLUSIONS: Standardizing calibration procedures is unlikely to decrease the analytical variability of creatinine assays enough to allow uniform and reliable use of the equations for estimation of glomerular filtration rate.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16232080     DOI: 10.1515/CCLM.2005.213

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  8 in total

Review 1.  Calibration and precision of serum creatinine and plasma cystatin C measurement: impact on the estimation of glomerular filtration rate.

Authors:  Pierre Delanaye; Etienne Cavalier; Jean-Paul Cristol; Joris R Delanghe
Journal:  J Nephrol       Date:  2014-04-08       Impact factor: 3.902

2.  Comparison of cystatin C and creatinine-based glomerular filtration rate formulas with 51Cr-EDTA clearance in patients with cirrhosis.

Authors:  Elias Xirouchakis; Laura Marelli; Evangelos Cholongitas; Pinelopi Manousou; Vincenza Calvaruso; Maria Pleguezuelo; Gian Piero Guerrini; Sergio Maimone; Andrew Kerry; Mark Hajjawi; Devaki Nair; Michael Thomas; David Patch; Andrew Kenneth Burroughs
Journal:  Clin J Am Soc Nephrol       Date:  2010-09-09       Impact factor: 8.237

3.  Impact of Isotope Dilution Mass Spectrometry (IDMS) Standardization on Carboplatin Dose and Adverse Events.

Authors:  Justin Lawson; Jeffrey M Switchenko; Trevor McKibbin; R Donald Harvey
Journal:  Pharmacotherapy       Date:  2016-06       Impact factor: 4.705

4.  Bowel preparation in CT colonography: electrolyte and renal function disturbances in the frail and elderly patient.

Authors:  Patrick Mc Laughlin; Joseph Eustace; Sean Mc Sweeney; Sebastian Mc Williams; Kevin O'Regan; Michael O'Connor; Denis Kelly; Michael M Maher
Journal:  Eur Radiol       Date:  2009-09-02       Impact factor: 5.315

5.  Comparison of glomerular filtration rate estimated by plasma clearance method with modification of diet in renal disease prediction equation and Gates method.

Authors:  N Prasad; S Barai; S Gambhir; D S Parasar; M Ora; A Gupta; R K Sharma
Journal:  Indian J Nephrol       Date:  2012-03

6.  9. GFR - Where are We Now?

Authors:  Joris R Delanghe
Journal:  EJIFCC       Date:  2009-04-20

7.  A Pathway to National Guidelines for Laboratory Diagnostics of Chronic Kidney Disease - Examples from Diverse European Countries.

Authors:  Vanja Radišić Biljak; Kristin Moberg Aakre; Dogan Yucel; Anne-Sophie Bargnoux; Jean-Paul Cristol; Laurence Piéroni
Journal:  EJIFCC       Date:  2017-12-19

8.  Did Creatinine Standardization Give Benefits to the Evaluation of Glomerular Filtration Rate?

Authors:  Laurence Piéroni; Anne-Sophie Bargnoux; Jean-Paul Cristol; Etienne Cavalier; Pierre Delanaye
Journal:  EJIFCC       Date:  2017-12-19
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.