Literature DB >> 16227046

Colorimetric end-tidal carbon dioxide detectors in the delivery room: strengths and limitations. A case report.

C Omar F Kamlin1, Colm P F O'Donnell, Peter G Davis, Colin J Morley.   

Abstract

Clinical assessment and end-tidal carbon dioxide (ETCO2) detectors are used to verify tracheal intubation in newborn infants. A case is presented in which an ETCO2 detector was misleading in determining endotracheal tube (ETT) position but useful in determining the efficacy of ventilation in an extremely preterm infant.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16227046     DOI: 10.1016/j.jpeds.2005.05.014

Source DB:  PubMed          Journal:  J Pediatr        ISSN: 0022-3476            Impact factor:   4.406


  10 in total

Review 1.  Are carbon dioxide detectors useful in neonates?

Authors:  E J Molloy; K Deakins
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2006-07       Impact factor: 5.747

2.  A novel airway device with tactile sensing capabilities for verifying correct endotracheal tube placement.

Authors:  Pauwel Goethals; Harshu Chaobal; Dominiek Reynaerts; David Schaner
Journal:  J Clin Monit Comput       Date:  2013-09-25       Impact factor: 2.502

3.  T-piece gas flow palpation as a clinical indicator of endotracheal intubation in neonates.

Authors:  Peter M Moran; Colin Patrick Hawkes; Eugene Michael Dempsey; C Anthony Ryan
Journal:  Eur J Pediatr       Date:  2012-12-28       Impact factor: 3.183

4.  Efficacy and user preference of two CO2 detectors in an infant mannequin randomized crossover trial.

Authors:  G A Hawkes; B J O'Connell; V Livingstone; C P Hawkes; C A Ryan; E M Dempsey
Journal:  Eur J Pediatr       Date:  2013-06-12       Impact factor: 3.183

5.  Assessment of endotracheal tube placement in newborn infants: a randomized controlled trial.

Authors:  S van Os; P-Y Cheung; K Kushniruk; M O'Reilly; K Aziz; G M Schmölzer
Journal:  J Perinatol       Date:  2016-01-14       Impact factor: 2.521

Review 6.  Question 2. Should carbon dioxide detectors be used to check correct placement of endotracheal tubes in preterm and term neonates?

Authors:  Harsha Gowda
Journal:  Arch Dis Child       Date:  2011-12       Impact factor: 3.791

Review 7.  WITHDRAWN: Techniques to ascertain correct endotracheal tube placement in neonates.

Authors:  Georg M Schmölzer; Charles Christoph C Roehr
Journal:  Cochrane Database Syst Rev       Date:  2018-07-05

8.  Case report: Intrapulmonary tidal volumes in a preterm infant with chest wall rigidity.

Authors:  Vincent D Gaertner; Tanja Restin; Dirk Bassler; Jean-Claude Fauchère; Christoph M Rüegger
Journal:  Front Pediatr       Date:  2022-08-23       Impact factor: 3.569

9.  Noninvasive Monitoring during Interhospital Transport of Newborn Infants.

Authors:  Georg M Schmölzer; Megan O'Reilly; Po-Yin Cheung
Journal:  Crit Care Res Pract       Date:  2013-02-24

10.  Short- and intermediate-term outcomes of preterm infants receiving positive pressure ventilation in the delivery room.

Authors:  Megan O'Reilly; Po-Yin Cheung; Khalid Aziz; Georg M Schmölzer
Journal:  Crit Care Res Pract       Date:  2013-01-17
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.