Literature DB >> 16220800

Long-span, fixed-movable, resin-bonded fixed partial dentures: a retrospective, preliminary clinical investigation.

Michael G Botelho1, John E Dyson.   

Abstract

PURPOSE: Long-span, resin-bonded fixed partial dentures (FPDs) have been associated with higher debonding rates than short-span prostheses. The use of modified nonrigid connectors that allow movement between the abutments in long-span resin-bonded prostheses may reduce harmful interabutment forces that stress the metal framework and resin-bonded interface. This preliminary investigation aimed to evaluate the longevity of long-span resin-bonded FPDs of 4 or more units with a modified nonrigid connector and increased extension of the retainer framework around the major abutment.
MATERIALS AND METHODS: Thirty-eight patients attended a clinical examination; each had been provided with 1 or more resin-bonded FPD of 4 or more units (43 prostheses). For each patient, the following data were recorded: gender, age, cementation date, and endodontic treatment, if performed. Data regarding the occurrence of any debondings and patient expectations were also recorded.
RESULTS: The mean service life for the 43 prostheses was 46.9 months (SD 22.0), with a range of 12 days to 87 months. Three prostheses had debonded, resulting in a clinical retention rate of 92.2%.
CONCLUSION: Long-span resin-bonded FPDs incorporating nonrigid connectors that allow independent movement between the major and minor retainer, combined with increased framework extension on the major abutment, appear successful in the short term. Further research is required to determine their long-term efficacy.

Entities:  

Mesh:

Year:  2005        PMID: 16220800

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  3 in total

1.  Structural stability of posterior retainer design for resin-bonded prostheses: a 3D finite element study.

Authors:  Jie Lin; Zhiqiang Zheng; Akikazu Shinya; Jukka Pekka Matinlinna; Michael George Botelho; Akiyoshi Shinya
Journal:  Odontology       Date:  2014-09-09       Impact factor: 2.634

2.  Non-Rigid Connector for Managing Pier Abutment in FPD: A Case Report.

Authors:  Ravikumar Suryakanth Akulwar; Ashwin Kodgi
Journal:  J Clin Diagn Res       Date:  2014-07-20

3.  Comparison of Tensile Bond Strength of Fixed-Fixed Versus Cantilever Single- and Double-Abutted Resin-Bonded Bridges Dental Prosthesis.

Authors:  Shweta Narwani; Naveen S Yadav; Puja Hazari; Vrinda Saxena; Abdulrahman H Alzahrani; Ahmed Alamoudi; Bassam Zidane; Nasreen Hassan Mohammed Albar; Ali Robaian; Sushil Kishnani; Kirti Somkuwar; Shilpa Bhandi; Kumar Chandan Srivastava; Deepti Shrivastava; Shankargouda Patil
Journal:  Materials (Basel)       Date:  2022-08-19       Impact factor: 3.748

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.