Literature DB >> 16216021

Transcatheter closure of large secundum atrial septal defects using the 40 mm Amplatzer septal occluder: results of an international registry.

Keila Lopez1, Bharat V Dalvi, David Balzer, John L Bass, Tarek Momenah, Qi-Ling Cao, Ziyad M Hijazi.   

Abstract

Little is known about the efficacy and safety of the 40 mm Amplatzer septal occluder (ASO). Thirty-three patients (22 female, 11 male) with a large secundum atrial septal defect (ASD) underwent attempted device closure using the 40 mm ASO at a median age of 40 years (range, 14-81 years) and median weight of 65 kg (range, 48-98 kg). The median size of the ASD measured on 2D transesophageal echocardiography (27 patients) or intracardiac echocardiography (6 patients) was 30.5 mm (range, 24-39 mm) and the median balloon-stretched diameter was 37.7 mm (range, 32-43.7 mm). The median Qp:Qs ratio was 3.2:1 (range, 1.4-6.2). The attempt was unsuccessful in five patients; two had device embolization and one had left atrial wall perforation due to the sheath; all three required emergent surgery. The attempt was successful in the 28 remaining patients, resulting in complete immediate closure in 14 and a trivial residual shunt in 14. Fluoroscopy time ranged from 8.6 to 37.8 min (median, 12.2 min). At 24-hr follow-up, 2D transthoracic echocardiography with color flow Doppler revealed complete closure in 23 patients, and 5 had a trivial residual shunt. There were no complications encountered in patients who received the device. On follow-up, all patients are doing well. We conclude that the 40 mm ASO is safe and effective in most patients with a large ASD up to a diameter of 39 mm. However, the use of this device requires careful attention as the procedure may be unsuccessful or the device may embolize. Copyright (c) 2005 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2005        PMID: 16216021     DOI: 10.1002/ccd.20468

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  14 in total

1.  Unusual atrial septal anatomy resulting in an interatrial chamber: the true triatrial heart?

Authors:  A J Javois; D A Roberson
Journal:  Pediatr Cardiol       Date:  2007 May-Jun       Impact factor: 1.655

2.  Impact of the Amplatzer atrial septal occluder device on left ventricular function in pediatric patients.

Authors:  Biagio Castaldi; Giuseppe Santoro; Giovanni Di Salvo; Gianpiero Gaio; Maria Teresa Palladino; Fabio D'Aiello; Carola Iacono; Giuseppe Pacileo; Raffaele Calabrò; Maria Giovanna Russo
Journal:  Pediatr Cardiol       Date:  2013-04-17       Impact factor: 1.655

3.  Assessment of atrial septal defects in adults comparing cardiovascular magnetic resonance with transoesophageal echocardiography.

Authors:  Karen S L Teo; Patrick J Disney; Benjamin K Dundon; Matthew I Worthley; Michael A Brown; Prashanthan Sanders; Stephen G Worthley
Journal:  J Cardiovasc Magn Reson       Date:  2010-07-22       Impact factor: 5.364

4.  Transcatheter closure of atrial septal defects: how large is too large?

Authors:  Alain Fraisse; Kalyani R Trivedi
Journal:  Cardiovasc Diagn Ther       Date:  2014-06

5.  Holter electrocardiography findings and P-wave dispersion in pediatric patients with transcatheter closure of atrial septal defects.

Authors:  Isa Ozyilmaz; Sinem Ozyilmaz; Hasan Tahsin Tola; Murat Saygi; Neslihan Kiplapinar; Cansaran Tanıdır; Yakup Ergul; Alper Guzeltas; Ender Odemis
Journal:  Ann Noninvasive Electrocardiol       Date:  2013-10-08       Impact factor: 1.468

6.  Utility of balloon assisted technique in trans catheter closure of very large (≥35 mm) atrial septal defects.

Authors:  Ajith Ananthakrishna Pillai; Vidhyakar Rangaswamy Balasubramanian; Raja Selvaraj; Maheshkumar Saktheeswaran; Santhosh Satheesh; Balachander Jayaraman
Journal:  Cardiovasc Diagn Ther       Date:  2014-02

7.  Should transcatheter closure of atrial septal defects with inferior-posterior deficient rim still be attempted?

Authors:  Pascal Amedro; Selin Bayburt; Anass Assaidi; Bernard Kreitmann; Gilbert Habib; Virginie Fouilloux; Alain Fraisse
Journal:  J Thorac Dis       Date:  2019-03       Impact factor: 2.895

8.  Ischemic stroke caused by paradoxical embolism after an unsuccessful transcatheter atrial septal defect closure procedure: a word of caution.

Authors:  Zhen-fei Fang; Liang Tang; Sheng-hua Zhou
Journal:  Pediatr Cardiol       Date:  2011-11-27       Impact factor: 1.655

9.  Transcatheter closure of atrial septal defect with amplatzer septal occluder in adults: immediate, short, and intermediate-term results.

Authors:  Mostafa Behjati; Mansour Rafiei; Mohammad Hossein Soltani; Mahmoud Emami; Majid Dehghani
Journal:  J Tehran Heart Cent       Date:  2011-05-31

10.  Midterm follow-up of transthoracic device closure of an atrial septal defect using the very large domestic occluder (44-48 mm), a single Chinese cardiac center experience.

Authors:  Qiang Chen; Hua Cao; Gui-Can Zhang; Liang-Wan Chen; Fan Xu; Jia-Xin Zhang
Journal:  J Cardiothorac Surg       Date:  2017-09-02       Impact factor: 1.637

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.