PURPOSE: To estimate the accuracy and consistency of a method using a voxel-based MR image registration algorithm for precise monitoring of knee joint diseases. MATERIALS AND METHODS: Rigid body transformation was calculated using a normalized cross-correlation (NCC) algorithm involving simple manual segmentation of the bone region based on its anatomical features. The accuracy of registration was evaluated using four phantoms, followed by a consistency test using MR data from the 11 patients with knee joint disease. RESULTS: The registration accuracy in the phantom experiment was 0.49+/-0.19 mm (SD) for the femur and 0.56+/-0.21 mm (SD) for the tibia. The consistency value in the experiment using clinical data was 0.69+/-0.25 mm (SD) for the femur and 0.77+/-0.37 mm (SD) for the tibia. These values were all smaller than a voxel (1.25 x 1.25 x 1.5 mm). CONCLUSION: The present method based on an NCC algorithm can be used to register serial MR images of the knee joint with error on the order of a sub-voxel. This method would be useful for precisely assessing therapeutic response and monitoring knee joint diseases; normalized cross-correlation; accuracy. J. Magn. Reson. Imaging 2005. (c) 2005 Wiley-Liss, Inc.
PURPOSE: To estimate the accuracy and consistency of a method using a voxel-based MR image registration algorithm for precise monitoring of knee joint diseases. MATERIALS AND METHODS: Rigid body transformation was calculated using a normalized cross-correlation (NCC) algorithm involving simple manual segmentation of the bone region based on its anatomical features. The accuracy of registration was evaluated using four phantoms, followed by a consistency test using MR data from the 11 patients with knee joint disease. RESULTS: The registration accuracy in the phantom experiment was 0.49+/-0.19 mm (SD) for the femur and 0.56+/-0.21 mm (SD) for the tibia. The consistency value in the experiment using clinical data was 0.69+/-0.25 mm (SD) for the femur and 0.77+/-0.37 mm (SD) for the tibia. These values were all smaller than a voxel (1.25 x 1.25 x 1.5 mm). CONCLUSION: The present method based on an NCC algorithm can be used to register serial MR images of the knee joint with error on the order of a sub-voxel. This method would be useful for precisely assessing therapeutic response and monitoring knee joint diseases; normalized cross-correlation; accuracy. J. Magn. Reson. Imaging 2005. (c) 2005 Wiley-Liss, Inc.
Authors: Jeff L Zhang; Eric E Sigmund; Hersh Chandarana; Henry Rusinek; Qun Chen; Pierre-Hugues Vivier; Bachir Taouli; Vivian S Lee Journal: Radiology Date: 2010-01-20 Impact factor: 11.105
Authors: Jeff L Zhang; Eric E Sigmund; Henry Rusinek; Hersh Chandarana; Pippa Storey; Qun Chen; Vivian S Lee Journal: Magn Reson Med Date: 2011-06-23 Impact factor: 4.668
Authors: Guobin Li; Jürgen Hennig; Esther Raithel; Martin Büchert; Dominik Paul; Jan G Korvink; Maxim Zaitsev Journal: MAGMA Date: 2015-01-09 Impact factor: 2.310