Application of 3D-MR image registration to monitor diseases around the knee joint.

Masaki Takao1, Nobuhiko Sugano, Takashi Nishii, Hidenobu Miki, Tsuyoshi Koyama, Jun Masumoto, Yoshinobu Sato, Shinichi Tamura, Hideki Yoshikawa.   

Abstract

PURPOSE: To estimate the accuracy and consistency of a method using a voxel-based MR image registration algorithm for precise monitoring of knee joint diseases.
MATERIALS AND METHODS: Rigid body transformation was calculated using a normalized cross-correlation (NCC) algorithm involving simple manual segmentation of the bone region based on its anatomical features. The accuracy of registration was evaluated using four phantoms, followed by a consistency test using MR data from the 11 patients with knee joint disease.
RESULTS: The registration accuracy in the phantom experiment was 0.49+/-0.19 mm (SD) for the femur and 0.56+/-0.21 mm (SD) for the tibia. The consistency value in the experiment using clinical data was 0.69+/-0.25 mm (SD) for the femur and 0.77+/-0.37 mm (SD) for the tibia. These values were all smaller than a voxel (1.25 x 1.25 x 1.5 mm).
CONCLUSION: The present method based on an NCC algorithm can be used to register serial MR images of the knee joint with error on the order of a sub-voxel. This method would be useful for precisely assessing therapeutic response and monitoring knee joint diseases; normalized cross-correlation; accuracy. J. Magn. Reson. Imaging 2005. (c) 2005 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2005        PMID: 16215970     DOI: 10.1002/jmri.20435

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  5 in total

1.  Volume rendering based on magnetic resonance imaging: advances in understanding the three-dimensional anatomy of the human knee.

Authors:  Giuseppe Anastasi; Placido Bramanti; Paolo Di Bella; Angelo Favaloro; Fabio Trimarchi; Ludovico Magaudda; Michele Gaeta; Emanuele Scribano; Daniele Bruschetta; Demetrio Milardi
Journal:  J Anat       Date:  2007-07-21       Impact factor: 2.610

2.  Variability of renal apparent diffusion coefficients: limitations of the monoexponential model for diffusion quantification.

Authors:  Jeff L Zhang; Eric E Sigmund; Hersh Chandarana; Henry Rusinek; Qun Chen; Pierre-Hugues Vivier; Bachir Taouli; Vivian S Lee
Journal:  Radiology       Date:  2010-01-20       Impact factor: 11.105

3.  Optimization of b-value sampling for diffusion-weighted imaging of the kidney.

Authors:  Jeff L Zhang; Eric E Sigmund; Henry Rusinek; Hersh Chandarana; Pippa Storey; Qun Chen; Vivian S Lee
Journal:  Magn Reson Med       Date:  2011-06-23       Impact factor: 4.668

4.  Incorporation of image data from a previous examination in 3D serial MR imaging.

Authors:  Guobin Li; Jürgen Hennig; Esther Raithel; Martin Büchert; Dominik Paul; Jan G Korvink; Maxim Zaitsev
Journal:  MAGMA       Date:  2015-01-09       Impact factor: 2.310

5.  Retrospective 3D registration of trabecular bone MR images for longitudinal studies.

Authors:  Jeremy F Magland; Catherine E Jones; Mary B Leonard; Felix W Wehrli
Journal:  J Magn Reson Imaging       Date:  2009-01       Impact factor: 4.813

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.