Literature DB >> 16214853

Optical clearing for improved contrast in second harmonic generation imaging of skeletal muscle.

Sergey Plotnikov1, Vaibhav Juneja, Ariel B Isaacson, William A Mohler, Paul J Campagnola.   

Abstract

Using second harmonic generation (SHG) imaging microscopy, we have examined the effect of optical clearing with glycerol to achieve greater penetration into specimens of skeletal muscle tissue. We find that treatment with 50% glycerol results in a 2.5-fold increase in achievable SHG imaging depth. Signal processing analyses using fast Fourier transform and continuous wavelet transforms show quantitatively that the periodicity of the sarcomere structure is unaltered by the clearing process and that image quality deep in the tissue is improved with clearing. Comparison of the SHG angular polarization dependence also shows no change in the supramolecular organization of acto-myosin complexes. By contrast, identical treatment of mouse tendon (collagen based) resulted in a strong decrease in SHG response. We suggest that the primary mechanism of optical clearing in muscle with glycerol treatment results from the reduction of cytoplasmic protein concentration and concomitant decrease in the secondary inner filter effect on the SHG signal. The lack of glycerol concentration dependence on the imaging depth indicates that refractive index matching plays only a minor role in the optical clearing of muscle. SHG and optical clearing may provide an ideal mechanism to study physiology in highly scattering skeletal or cardiac muscle tissue with significantly improved depth of penetration and achievable imaging depth.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16214853      PMCID: PMC1367031          DOI: 10.1529/biophysj.105.066944

Source DB:  PubMed          Journal:  Biophys J        ISSN: 0006-3495            Impact factor:   4.033


  37 in total

1.  Three-dimensional high-resolution second-harmonic generation imaging of endogenous structural proteins in biological tissues.

Authors:  Paul J Campagnola; Andrew C Millard; Mark Terasaki; Pamela E Hoppe; Christian J Malone; William A Mohler
Journal:  Biophys J       Date:  2002-01       Impact factor: 4.033

2.  Dynamic optical coherence tomography in studies of optical clearing, sedimentation, and aggregation of immersed blood.

Authors:  Valery V Tuchin; Xiangqun Xu; Ruikang K Wang
Journal:  Appl Opt       Date:  2002-01-01       Impact factor: 1.980

Review 3.  Non-invasive in vivo characterization of breast tumors using photon migration spectroscopy.

Authors:  B J Tromberg; N Shah; R Lanning; A Cerussi; J Espinoza; T Pham; L Svaasand; J Butler
Journal:  Neoplasia       Date:  2000 Jan-Apr       Impact factor: 5.715

4.  Live tissue intrinsic emission microscopy using multiphoton-excited native fluorescence and second harmonic generation.

Authors:  Warren R Zipfel; Rebecca M Williams; Richard Christie; Alexander Yu Nikitin; Bradley T Hyman; Watt W Webb
Journal:  Proc Natl Acad Sci U S A       Date:  2003-05-19       Impact factor: 11.205

5.  3-dimensional imaging of collagen using second harmonic generation.

Authors:  Guy Cox; Eleanor Kable; Allan Jones; Ian Fraser; Frank Manconi; Mark D Gorrell
Journal:  J Struct Biol       Date:  2003-01       Impact factor: 2.867

6.  Imaging cells and extracellular matrix in vivo by using second-harmonic generation and two-photon excited fluorescence.

Authors:  Aikaterini Zoumi; Alvin Yeh; Bruce J Tromberg
Journal:  Proc Natl Acad Sci U S A       Date:  2002-08-12       Impact factor: 11.205

7.  Characterization of the myosin-based source for second-harmonic generation from muscle sarcomeres.

Authors:  Sergey V Plotnikov; Andrew C Millard; Paul J Campagnola; William A Mohler
Journal:  Biophys J       Date:  2005-10-28       Impact factor: 4.033

8.  Selective corneal imaging using combined second-harmonic generation and two-photon excited fluorescence.

Authors:  Alvin T Yeh; Nader Nassif; Aikaterini Zoumi; Bruce J Tromberg
Journal:  Opt Lett       Date:  2002-12-02       Impact factor: 3.776

9.  Chemical specificity in three-dimensional imaging with multiplex coherent anti-Stokes Raman scattering microscopy.

Authors:  George W H Wurpel; Juleon M Schins; Michiel Müller
Journal:  Opt Lett       Date:  2002-07-01       Impact factor: 3.776

10.  Influence of optical properties on two-photon fluorescence imaging in turbid samples.

Authors:  A K Dunn; V P Wallace; M Coleno; M W Berns; B J Tromberg
Journal:  Appl Opt       Date:  2000-03-01       Impact factor: 1.980

View more
  30 in total

1.  Texture analysis applied to second harmonic generation image data for ovarian cancer classification.

Authors:  Bruce L Wen; Molly A Brewer; Oleg Nadiarnykh; James Hocker; Vikas Singh; Thomas R Mackie; Paul J Campagnola
Journal:  J Biomed Opt       Date:  2014-09       Impact factor: 3.170

2.  Noninvasive assessment of collagen gel microstructure and mechanics using multiphoton microscopy.

Authors:  Christopher B Raub; Vinod Suresh; Tatiana Krasieva; Julia Lyubovitsky; Justin D Mih; Andrew J Putnam; Bruce J Tromberg; Steven C George
Journal:  Biophys J       Date:  2006-12-15       Impact factor: 4.033

3.  Second harmonic generation confocal microscopy of collagen type I from rat tendon cryosections.

Authors:  Theodossis A Theodossiou; Christopher Thrasivoulou; Chidi Ekwobi; David L Becker
Journal:  Biophys J       Date:  2006-12-15       Impact factor: 4.033

4.  The role of backscattering in SHG tissue imaging.

Authors:  François Légaré; Christian Pfeffer; Bjorn R Olsen
Journal:  Biophys J       Date:  2007-04-20       Impact factor: 4.033

5.  Simultaneous determination of the second-harmonic generation emission directionality and reduced scattering coefficient from three-dimensional imaging of thick tissues.

Authors:  Gunnsteinn Hall; Kevin W Eliceiri; Paul J Campagnola
Journal:  J Biomed Opt       Date:  2013-11       Impact factor: 3.170

Review 6.  Muscle quality in aging: a multi-dimensional approach to muscle functioning with applications for treatment.

Authors:  Maren S Fragala; Anne M Kenny; George A Kuchel
Journal:  Sports Med       Date:  2015-05       Impact factor: 11.136

7.  Thermal transitions of fibrillar collagen unveiled by second-harmonic generation microscopy of corneal stroma.

Authors:  Paolo Matteini; Riccardo Cicchi; Fulvio Ratto; Dimitrios Kapsokalyvas; Francesca Rossi; Marella de Angelis; Francesco S Pavone; Roberto Pini
Journal:  Biophys J       Date:  2012-09-19       Impact factor: 4.033

Review 8.  Second harmonic generation imaging microscopy: applications to diseases diagnostics.

Authors:  Paul Campagnola
Journal:  Anal Chem       Date:  2011-03-29       Impact factor: 6.986

9.  Quantitative second harmonic generation imaging of the diseased state osteogenesis imperfecta: experiment and simulation.

Authors:  Ronald Lacomb; Oleg Nadiarnykh; Paul J Campagnola
Journal:  Biophys J       Date:  2008-02-15       Impact factor: 4.033

10.  Clearing skeletal muscle with CLARITY for light microscopy imaging.

Authors:  Andrew Milgroom; Evelyn Ralston
Journal:  Cell Biol Int       Date:  2016-02-15       Impact factor: 3.612

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.