MR safety and compatibility of a noninvasively expandable total-joint endoprosthesis.

Robert J Ogg1, C Brian McDaniel, Donald Wallace, Pierre Pitot, Michael D Neel, Sue C Kaste.   

Abstract

A noninvasively expandable total-joint endoprosthesis is now available for pediatric patients; the prosthesis can be lengthened by external application of a magnetic field. We investigated the risks of unintentional heating or lengthening of the prosthesis during MR imaging and evaluated the effect of the device on the diagnostic efficacy of MR imaging of surrounding tissues. We performed MR imaging at 1.5 T by using standard pulse sequences and pulse sequences with high-gradient and high-radiofrequency duty cycle. MR imaging caused no measurable change in prosthesis length, and the temperature of the prosthesis increased by less than 1 degrees C during repeated 14-min exposures. Despite significant signal loss and image distortion around the prosthetic joint, clinically useful images were obtained as close as 12 cm from the ends of the prosthetic stems, measured toward the body of the device. Thus, the prosthesis can be safely exposed to MR imaging pulse sequences at 1.5 T, and the visualization of some tissue surrounding the device is clinically useful.

Entities:  

Mesh:

Year:  2005        PMID: 16214609     DOI: 10.1016/j.mri.2005.06.008

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  3 in total

1.  Safety and compatibility of magnetic-controlled growing rods and magnetic resonance imaging.

Authors:  Henry R Budd; Oliver M Stokes; Judith Meakin; Jonathan Fulford; Michael Hutton
Journal:  Eur Spine J       Date:  2015-08-14       Impact factor: 3.134

2.  In vivo dentate nucleus MRI relaxometry correlates with previous administration of Gadolinium-based contrast agents.

Authors:  Enrico Tedeschi; Giuseppe Palma; Antonietta Canna; Sirio Cocozza; Carmela Russo; Pasquale Borrelli; Roberta Lanzillo; Valentina Angelini; Emanuela Postiglione; Vincenzo Brescia Morra; Marco Salvatore; Arturo Brunetti; Mario Quarantelli
Journal:  Eur Radiol       Date:  2016-02-23       Impact factor: 5.315

3.  Novel MR imaging method--MAVRIC--for metal artifact suppression after joint replacement in musculoskeletal tumor patients.

Authors:  Michiro Susa; Sota Oguro; Kazutaka Kikuta; Kazumasa Nishimoto; Keisuke Horiuchi; Masahiro Jinzaki; Masaya Nakamura; Morio Matsumoto; Kazuhiro Chiba; Hideo Morioka
Journal:  BMC Musculoskelet Disord       Date:  2015-12-04       Impact factor: 2.362

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.