Literature DB >> 16214534

High level of cerebral microembolization in patients supported with the DeBakey left ventricular assist device.

Nils H Thoennissen1, Michael Schneider, Achim Allroggen, Martin Ritter, Ralf Dittrich, Christof Schmid, Hans H Scheld, E Bernd Ringelstein, Darius G Nabavi.   

Abstract

OBJECTIVE: Microembolic signals detected by transcranial Doppler ultrasonography have been demonstrated to be clinically relevant in patients supported with pulsatile left ventricular assist devices. We prospectively investigated the quantity of microembolic signals in patients supported with the continuous-flow DeBakey left ventricular assist device (MicroMed DeBakey VAD; MicroMed Technology, Inc, Houston, Tex) including the refined Carmeda BioActive Surface system (Carmeda AB, Stockholm, Sweden).
METHODS: Twenty-three patients (20 male) aged 14 to 62 years supported with DeBakey left ventricular assist devices (n = 6 with Carmeda) were enrolled in this study. Microembolic signal monitorings were performed twice weekly by insonating the middle cerebral artery for 20 minutes without and 20 minutes with oronasal application of oxygen (6 L/min). Evidence of clinically manifest thromboembolic events was based on regular questionnaires, clinical examinations, and results of diagnostic procedures.
RESULTS: Despite a low incidence of thromboembolic complications (0.24 per 100 left ventricular assist device days), 20 patients (87%) showed circulating microemboli. Overall, microembolic signals were found in 175 of 499 transcranial Doppler ultrasonographic examinations (35.1%), with mean counts of 81.2 +/- 443 (range 0-5042 signals/h). Both microembolic signal prevalence (25% vs 34%, P = .01) and absolute signal counts (46.5 vs 104, P < .01) significantly declined with oxygen delivery. There was no significant correlation between the individual microembolic signal activity and the incidence of clinical thromboembolism or the intensity of antihemostatic treatment. Patients supported with the Carmeda device did not show reduced rates of clinical thromboembolization or cerebral microemboli.
CONCLUSION: In patients with DeBakey left ventricular assist devices, a high load of clinically silent microemboli can be detected within the cerebral arteries despite a low incidence of embolic complications. It needs to be investigated whether such continuous, presumably gaseous microembolization causes cognitive or neuropsychologic deficits.

Entities:  

Mesh:

Year:  2005        PMID: 16214534     DOI: 10.1016/j.jtcvs.2005.02.068

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  11 in total

Review 1.  The use of computational fluid dynamics in the development of ventricular assist devices.

Authors:  Katharine H Fraser; M Ertan Taskin; Bartley P Griffith; Zhongjun J Wu
Journal:  Med Eng Phys       Date:  2010-11-13       Impact factor: 2.242

2.  Ventricular Assist Device Implantation Configurations Impact Overall Mechanical Circulatory Support System Thrombogenic Potential.

Authors:  Wei-Che Chiu; Yared Alemu; Allison J McLarty; Shmuel Einav; Marvin J Slepian; Danny Bluestein
Journal:  ASAIO J       Date:  2017 May/Jun       Impact factor: 2.872

3.  Quantification of aortic valve area: comparison of different methods of echocardiography with 3-D scan of the excised valve.

Authors:  Samira Shirazi; Fatemeh Golmohammadi; Anahita Tavoosi; Mehrdad Salehi; Farnoosh Larti; Akram Sardari; Babak Geraiely; Mehrzad Rahmanian; Kianoush Saberi; Roya Sattarzadeh Badkoubeh
Journal:  Int J Cardiovasc Imaging       Date:  2020-10-01       Impact factor: 2.357

4.  A case of postoperative cognitive decline, with a highly elevated C- reactive protein, status post left ventricular assist device insertion: a review of the neuroinflammatory hypothesis of delirium.

Authors:  David R Spiegel; Victoria Chen
Journal:  Innov Clin Neurosci       Date:  2012-01

5.  Hematologic effects of continuous flow left ventricular assist devices.

Authors:  Mark S Slaughter
Journal:  J Cardiovasc Transl Res       Date:  2010-09-11       Impact factor: 4.132

Review 6.  The biological basis of thrombosis and bleeding in patients with ventricular assist devices.

Authors:  Ranjit John; Sangjin Lee
Journal:  J Cardiovasc Transl Res       Date:  2008-10-17       Impact factor: 4.132

7.  Frequency analysis of high-intensity transient signals of transcranial Doppler ultrasound in patients supported with a left ventricular assist device.

Authors:  Koichi Sato; Kazuhiko Hanzawa; Takeshi Okamoto; Shunei Kyo; Jun-ichi Hayashi
Journal:  J Artif Organs       Date:  2008-12-17       Impact factor: 1.731

Review 8.  Psychiatric aspects of organ transplantation in critical care.

Authors:  Andrea DiMartini; Catherine Crone; Marian Fireman; Mary Amanda Dew
Journal:  Crit Care Clin       Date:  2008-10       Impact factor: 3.598

9.  Stroke Incidence and Impact of Continuous-Flow Left Ventricular Assist Devices on Cerebrovascular Physiology.

Authors:  William K Cornwell; Amrut V Ambardekar; Tomio Tran; Jay D Pal; Luis Cava; Justin Lawley; Takashi Tarumi; Christy L Cornwell; Keith Aaronson
Journal:  Stroke       Date:  2019-02       Impact factor: 7.914

10.  Numerical investigation of the effect of cannula placement on thrombosis.

Authors:  ChiWei Ong; Socrates Dokos; BeeTing Chan; Einly Lim; Amr Al Abed; Noor Azuan Bin Abu Osman; Suhaini Kadiman; Nigel H Lovell
Journal:  Theor Biol Med Model       Date:  2013-05-16       Impact factor: 2.432

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.