BACKGROUND: Endoscopic retrograde cholangiopancreatography (ERCP) relies on the use of ionising radiation but risks to operator and patient associated with radiation exposure are unclear. The aim of this prospective study was to estimate the radiation dose received by personnel performing fluoroscopic endoscopic procedures, mainly ERCP. METHODS: Consecutive procedures over a two month period were included. The use of thermoluminescent dosimeters to measure radiation exposure to the abdomen, thyroid gland, and hands of the operator permitted an estimation of the annual whole body effective dose equivalent. RESULTS: During the study period 66 procedures (61 ERCP) were performed and the estimated annual whole body effective dose equivalent received by consultant operators ranged between 3.35 and 5.87 mSv. These values are similar to those received by patients undergoing barium studies and equate to an estimated additional lifetime fatal cancer risk between 1 in 7000 and 1 in 3500. While within legal safety limits for radiation exposure to personnel, these doses are higher than values deemed acceptable for the general public. CONCLUSIONS: It is suggested that personnel as well as patients may be exposed to significant values of radiation during ERCP. The study emphasises the need to carefully assess the indication for, and to use measures that minimise radiation exposure during any fluoroscopic procedure.
BACKGROUND: Endoscopic retrograde cholangiopancreatography (ERCP) relies on the use of ionising radiation but risks to operator and patient associated with radiation exposure are unclear. The aim of this prospective study was to estimate the radiation dose received by personnel performing fluoroscopic endoscopic procedures, mainly ERCP. METHODS: Consecutive procedures over a two month period were included. The use of thermoluminescent dosimeters to measure radiation exposure to the abdomen, thyroid gland, and hands of the operator permitted an estimation of the annual whole body effective dose equivalent. RESULTS: During the study period 66 procedures (61 ERCP) were performed and the estimated annual whole body effective dose equivalent received by consultant operators ranged between 3.35 and 5.87 mSv. These values are similar to those received by patients undergoing barium studies and equate to an estimated additional lifetime fatal cancer risk between 1 in 7000 and 1 in 3500. While within legal safety limits for radiation exposure to personnel, these doses are higher than values deemed acceptable for the general public. CONCLUSIONS: It is suggested that personnel as well as patients may be exposed to significant values of radiation during ERCP. The study emphasises the need to carefully assess the indication for, and to use measures that minimise radiation exposure during any fluoroscopic procedure.
Authors: E Masci; G Toti; A Mariani; S Curioni; A Lomazzi; M Dinelli; G Minoli; C Crosta; U Comin; A Fertitta; A Prada; G R Passoni; P A Testoni Journal: Am J Gastroenterol Date: 2001-02 Impact factor: 10.864
Authors: R V Cohen; M A Aldred; W S Paes; A M Fausto; J R Nucci; E M Yoshimura; E Okuno; M E Garcia; L M Maruta; E M Tolosa Journal: Surg Endosc Date: 1997-06 Impact factor: 4.584
Authors: Kwang Pyo Kim; Donald L Miller; Amy Berrington de Gonzalez; Stephen Balter; Ruth A Kleinerman; Evgenia Ostroumova; Steven L Simon; Martha S Linet Journal: Health Phys Date: 2012-07 Impact factor: 1.316
Authors: Amer A Alkhatib; Ala A Abdel Jalil; Douglas O Faigel; Rahul Pannala; Michael Crowell; M E Harrison Journal: Dig Dis Sci Date: 2015-02-04 Impact factor: 3.199
Authors: Thiruvengadam Muniraj; Harry R Aslanian; Loren Laine; James Farrell; Maria M Ciarleglio; Yanhong Deng; Henry Ho; Priya A Jamidar Journal: Am J Gastroenterol Date: 2015-03-31 Impact factor: 10.864
Authors: Keith Siau; George Webster; Mark Wright; Ben Maher; Brian Stedman; Gavin Johnson; Saqib Ahmad; Nadeem Tehami Journal: Frontline Gastroenterol Date: 2020-12-11
Authors: Jae Min Shin; Tae Hoon Lee; Sang-Heum Park; Sang Goo Kang; Yeon Seon Lee; Suk Ja Park; Mi Gyeong Ku; Suck-Ho Lee; Il-Kwun Chung; Hyun Jong Choi; Jong Ho Moon; Sang Woo Cha; Young Deok Cho; Sun-Joo Kim Journal: Gut Liver Date: 2012-11-13 Impact factor: 4.519