Pulsed electron avalanche knife in vitreoretinal surgery.

Siegfried G Priglinger1, Christos Haritoglou, Arthur Mueller, Martin Grueterich, Rupert W Strauss, Claudia S Alge, Arnd Gandorfer, Daniel Palanker, Anselm Kampik.   

Abstract

PURPOSE: To evaluate the advantages, disadvantages, safety, and surgical applicability of the pulsed electron avalanche knife (PEAK-fc), a new electrosurgical knife for "cold" and tractionless cutting, in vitreoretinal surgery. PEAK-fc is equipped with an integrated fiberoptic that makes bimanual procedures in intraocular surgery possible.
METHODS: A prospective consecutive trial of 18 eyes in 18 patients who underwent vitreoretinal surgery for proliferative diabetic retinopathy, proliferative vitreoretinopathy, subretinal macular hemorrhage, or macular pucker was performed. The following specific maneuvers were performed with PEAK-fc: transection of epiretinal membranes, retinotomies, retinal vessel coagulation, and posterior membranectomy.
RESULTS: Detached and attached retina could be dissected successfully in eight cases. Intraoperatively, incision edges were sharply demarcated, showing no visible collateral damage. Deeper layers than the neurosensory retina were not affected. With the bimanual approach, epiretinal avascular and vascular membranes could be removed in 10 cases. Hemorrhages occurring during transection of vascularized membranes could be stopped immediately using the coagulation mode of PEAK-fc. Posterior capsule fibrosis was successfully excised in one patient. No complications were observed.
CONCLUSION: PEAK-fc offers precise and tractionless tissue cutting during ocular surgery. Using different waveform parameters, the same device performs cold cutting and/or "hot" coagulation, thus improving the precision, safety, and ergonomics of vitreoretinal surgery.

Entities:  

Mesh:

Year:  2005        PMID: 16205569     DOI: 10.1097/00006982-200510000-00012

Source DB:  PubMed          Journal:  Retina        ISSN: 0275-004X            Impact factor:   4.256


  4 in total

1.  Pulsed electron avalanche knife: new technology for cataract surgery.

Authors:  Siegfried G Priglinger; Daniel Palanker; Claudia S Alge; Thomas C Kreutzer; Christos Haritoglou; Martin Grueterich; Anselm Kampik
Journal:  Br J Ophthalmol       Date:  2007-01-17       Impact factor: 4.638

2.  Anterior capsulotomy with a pulsed-electron avalanche knife.

Authors:  Daniel Palanker; Hiroyuki Nomoto; Philip Huie; Alexander Vankov; David F Chang
Journal:  J Cataract Refract Surg       Date:  2010-01       Impact factor: 3.351

Review 3.  Energetic soft-tissue treatment technologies: an overview of procedural fundamentals and safety factors.

Authors:  N J van de Berg; J J van den Dobbelsteen; F W Jansen; C A Grimbergen; J Dankelman
Journal:  Surg Endosc       Date:  2013-04-10       Impact factor: 4.584

4.  A Model to Study Thermal Energy Delivery to the Choroid: A Comparison of Surgical Devices.

Authors:  Stephen A LoBue; Prashant Tailor; Jarel K Gandhi; Paul Loftness; Timothy W Olsen
Journal:  Transl Vis Sci Technol       Date:  2018-12-28       Impact factor: 3.283

  4 in total