Literature DB >> 16205046

Assessment of the pulmonary volume pulse in idiopathic pulmonary arterial hypertension by means of electrical impedance tomography.

Henk J Smit1, Anton Vonk-Noordegraaf, Anco Boonstra, Peter M de Vries, Pieter E Postmus.   

Abstract

BACKGROUND: Electrical impedance tomography (EIT) is a non-invasive imaging technique which can be used to measure the blood volume changes in the pulmonary vascular bed during the cardiac cycle. STUDY
OBJECTIVES: This study was performed to evaluate the differences in the EIT signal of the pulmonary vascular bed between healthy subjects and patients with idiopathic pulmonary arterial hypertension (IPAH), who are known to have a remodelled pulmonary vascular bed. PATIENTS AND METHODS: Twenty-one patients (17 females, 4 males) with IPAH and 30 healthy controls (5 females, 25 males) were measured. EIT measurements were performed in duplicate, on the same day as right heart catheterization to obtain haemodynamic data. The maximal impedance change during systole (Delta Z(sys)) was used as a measure of the pulmonary volume pulse and expressed in arbitrary units (AU). Total lung capacity, spirometric values and diffusion capacity for carbon monoxide were measured as well.
RESULTS: Mean Delta Z(sys) was 215 +/- 58 x 10(-2) AU (95% CI 193 x 10(-2) to 236 x 10(-2)) in the healthy subjects and 78 +/- 27 x 10(-2) AU (95% CI 66 x 10(-2) to 91 x 10(-2)) in the IPAH patient group (p < 0.0001). No significant correlation was found between Delta Z(sys) and any of the haemodynamic or lung function data.
CONCLUSION: The impedance pulsation of the pulmonary vascular bed is reduced in IPAH in comparison with controls, indicating a reduced volume pulse. This might represent the reduced cross section area, as well as the reduced compliance and number of the pulmonary vessels in these patients.

Entities:  

Mesh:

Year:  2005        PMID: 16205046     DOI: 10.1159/000088694

Source DB:  PubMed          Journal:  Respiration        ISSN: 0025-7931            Impact factor:   3.580


  6 in total

1.  Noninvasive pulmonary artery pressure monitoring by EIT: a model-based feasibility study.

Authors:  Martin Proença; Fabian Braun; Josep Solà; Jean-Philippe Thiran; Mathieu Lemay
Journal:  Med Biol Eng Comput       Date:  2016-09-17       Impact factor: 2.602

Review 2.  Electrical impedance tomography: the holy grail of ventilation and perfusion monitoring?

Authors:  Steffen Leonhardt; Burkhard Lachmann
Journal:  Intensive Care Med       Date:  2012-09-20       Impact factor: 17.440

3.  Semi-Siamese U-Net for separation of lung and heart bioimpedance images: A simulation study of thorax EIT.

Authors:  Yen-Fen Ko; Kuo-Sheng Cheng
Journal:  PLoS One       Date:  2021-02-02       Impact factor: 3.240

4.  Non-invasive pulmonary artery pressure estimation by electrical impedance tomography in a controlled hypoxemia study in healthy subjects.

Authors:  Martin Proença; Fabian Braun; Mathieu Lemay; Josep Solà; Andy Adler; Thomas Riedel; Franz H Messerli; Jean-Philippe Thiran; Stefano F Rimoldi; Emrush Rexhaj
Journal:  Sci Rep       Date:  2020-12-08       Impact factor: 4.379

5.  Electrical impedance tomography in pulmonary arterial hypertension.

Authors:  André L D Hovnanian; Eduardo L V Costa; Susana Hoette; Caio J C S Fernandes; Carlos V P Jardim; Bruno A Dias; Luciana T K Morinaga; Marcelo B P Amato; Rogério Souza
Journal:  PLoS One       Date:  2021-03-17       Impact factor: 3.240

6.  Accuracy and reliability of noninvasive stroke volume monitoring via ECG-gated 3D electrical impedance tomography in healthy volunteers.

Authors:  Fabian Braun; Martin Proença; Andy Adler; Thomas Riedel; Jean-Philippe Thiran; Josep Solà
Journal:  PLoS One       Date:  2018-01-26       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.