Literature DB >> 16204741

Clinical experience with a circumferential clip-based vascular closure device in diagnostic catheterization.

James Hermiller1, Charles Simonton, Tom Hinohara, Daniel Lee, Louis Cannon, Michael Mooney, Charles O'Shaughnessy, Harold Carlson, Richard Fortuna, Carol Anne Yarbrough, Michael Zapien, Tony Chou.   

Abstract

BACKGROUND: The StarClose Vascular Closure System (Abbott Vascular Devices, Redwood City, California) utilizes a small, flexible nitinol clip to complete a circumferential, extravascular closure of the femoral arteriotomy site. The StarClose is an investigational device in the United States, limited by Federal law to investigational use. The StarClose is CE Mark approved.
METHODS: The CLIP study was a prospective, randomized, multicenter trial utilizing a noninferiority design to compare the rate of major vascular complications and time-to-hemostasis using the StarClose system versus manual compression. A total of 596 subjects were enrolled, 208 of whom underwent diagnostic angiography. This diagnostic subset is the focus of this report. The primary safety endpoint was major vascular complications and the primary efficacy endpoint was time-to-hemostasis. All patients were followed at 30 days with a clinical exam.
RESULTS: Subjects were randomized 2:1 to the StarClose (n = 136) or manual compression (n = 72). There were no major vascular complications in either group. Minor vascular complications occurred in 3 StarClose patients (2.2%), and 1 manual compression patient (1.4%) (p = 1.00). Use of the StarClose device reduced mean time-to-hemostasis from 15.47 +/- 11.4 to 1.46 +/- 4.5 minutes (p < 0.001) when compared to manual compression, and reduced the average time-to-ambulation from 269 +/- 135 to 163 +/- 105 minutes (p < or = 0.001). Device success was 94.1% (127/135), and procedural success was 100% (136/136).
CONCLUSION: The clinical results of this study concluded that the StarClose Vascular Closure System is noninferior to standard compression with respect to the the primary safety endpoint of closing arteriotomies in patients who undergo percutaneous diagnostic procedures.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16204741

Source DB:  PubMed          Journal:  J Invasive Cardiol        ISSN: 1042-3931            Impact factor:   2.022


  7 in total

1.  StarClose vascular closure device: safety and efficacy of deployment and reaccess in a neurointerventional radiology service.

Authors:  R A McTaggart; D Raghavan; R A Haas; M V Jayaraman
Journal:  AJNR Am J Neuroradiol       Date:  2010-01-21       Impact factor: 3.825

2.  Angio-Seal™ Evolution™ versus Manual Compression for Common Femoral Artery Puncture in Neurovascular Diagnostic Angiography : A Prospective, Non-Randomized Study.

Authors:  Joonho Chung; Dong Woo Lee; Ok Sim Kwon; Bum-Soo Kim; Yong Sam Shin
Journal:  J Korean Neurosurg Soc       Date:  2011-03-31

3.  Comparison of Angioseal and Manual Compression in Patients Undergoing Transfemoral Coronary and Peripheral Vascular Interventional Procedures.

Authors:  Abdullah M Alshehri; Mohamed Elsharawy
Journal:  Int J Angiol       Date:  2015-06

4.  Short-Term Safety and Efficacy of Femoral Vascular Closure after Percutaneous Coronary Intervention with Combination of the Boomerang(TM) Device and Intravenous Protamine Sulfate.

Authors:  Ching-Pei Chen; Huang-Kai Huang; Chien-Hsun Hsia; Yung-Ming Chang; Lee-Shin Lin; Cheng-Liang Lee
Journal:  Acta Cardiol Sin       Date:  2013-11       Impact factor: 2.672

5.  Vascular closure device failure: frequency and implications: a propensity-matched analysis.

Authors:  Sripal Bangalore; Nipun Arora; Frederic S Resnic
Journal:  Circ Cardiovasc Interv       Date:  2009-10-27       Impact factor: 6.546

6.  Vascular Closure Devices versus Manual Compression in Cardiac Interventional Procedures: Systematic Review and Meta-Analysis.

Authors:  Naidong Pang; Jia Gao; Binghang Zhang; Min Guo; Nan Zhang; Meng Sun; Rui Wang
Journal:  Cardiovasc Ther       Date:  2022-09-09       Impact factor: 3.368

7.  Safety and efficacy of the StarClose vascular closure system following 8-Fr sheath placement for intra-aortic balloon pump: a single-center analysis of 42 consecutive patients.

Authors:  Guang Chu; Wenyi Yang; Guobing Zhang; Zhi Zhang; Shaowen Liu; Baogui Sun; Fang Wang
Journal:  Med Princ Pract       Date:  2014-04-23       Impact factor: 1.927

  7 in total