Literature DB >> 16204714

Detection and localization of prostate cancer: correlation of (11)C-choline PET/CT with histopathologic step-section analysis.

Mohsen Farsad1, Riccardo Schiavina, Paolo Castellucci, Cristina Nanni, Barbara Corti, Giuseppe Martorana, Romeo Canini, Walter Grigioni, Stefano Boschi, Mario Marengo, Cinzia Pettinato, Eugenio Salizzoni, Nino Monetti, Roberto Franchi, Stefano Fanti.   

Abstract

UNLABELLED: This study evaluated the potential usefulness of (11)C-choline PET/CT for detection and localization of tumors within the prostate. We used the results of step-section histopathologic examination as the standard of reference.
METHODS: The results were analyzed on a sextant basis. We reviewed the results of the (11)C-choline PET/CT scans of 36 patients with prostate cancer and of 5 control subjects with bladder cancer. All patients underwent (11)C-choline PET/CT and, subsequently, radical prostatectomy with lymph node dissection within 1 mo. (11)C-Choline PET/CT scans were obtained 5-10 min after intravenous injection of 370-555 MBq of (11)C-choline. Images were reviewed visually and semiquantitatively using maximum SUV and tumor-to-background ratio.
RESULTS: On a sextant basis, histopathologic analysis detected cancer foci in 143 of 216 sextants; high-grade prostate intraepithelial neoplasm foci were detected in 89 of 216 sextants (in 59 sextants in association with carcinoma, in 30 sextants alone), acute prostatitis was detected in 7 of 216 sextants (in 3 sextants in association with carcinoma, in 4 sextants alone), and 39 of 216 sextants were normal. PET/CT demonstrated focal (11)C-choline uptake in 108 sextants (94 of which involved tumor), and 108 sextants showed no abnormal (11)C-choline uptake (49 of which were false negative). The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of PET/CT were 66%, 81%, 71%, 87%, and 55%, respectively. In the 5 control subjects, high-grade prostate intraepithelial neoplasm was detected at histologic examination in 16 of 30 sextants. PET/CT showed increased (11)C-choline uptake in 5 of 16 sextants.
CONCLUSION: This study demonstrated the feasibility of using (11)C-choline PET/CT to identify cancer foci within the prostate. However, we also found that (11)C-choline PET/CT has a relative high rate of false-negative results on a sextant basis and that prostatic disorders other than cancer may accumulate (11)C-choline. Therefore, our data do not support the routine use of PET/CT with (11)C-choline as a first-line screening procedure for prostate cancer in men at high risk.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16204714

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  79 in total

Review 1.  Positron emission tomography for benign and malignant disease.

Authors:  Anthony Visioni; Julian Kim
Journal:  Surg Clin North Am       Date:  2011-02       Impact factor: 2.741

2.  11C/ 18F-choline PET or 11C/18F-acetate PET in prostate cancer: may a choice be recommended?

Authors:  Cristina Nanni; Paolo Castellucci; Mohsen Farsad; Domenico Rubello; Stefano Fanti
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-10       Impact factor: 9.236

3.  [(11)C]choline PET/CT in prostate cancer patients with biochemical recurrence after radical prostatectomy.

Authors:  Ludwig Rinnab; Joerg Simon; Richard E Hautmann; M V Cronauer; Kathrin Hohl; Andreas K Buck; Sven N Reske; Felix M Mottaghy
Journal:  World J Urol       Date:  2009-02-21       Impact factor: 4.226

Review 4.  Radiopharmaceuticals as probes to characterize tumour tissue.

Authors:  Israt S Alam; Mubarik A Arshad; Quang-Dé Nguyen; Eric O Aboagye
Journal:  Eur J Nucl Med Mol Imaging       Date:  2015-02-03       Impact factor: 9.236

5.  Do we have to withdraw antiandrogenic therapy in prostate cancer patients before PET/CT with [11C]choline?

Authors:  Giampiero Giovacchini
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-11       Impact factor: 9.236

6.  Tumour volume delineation in prostate cancer assessed by [11C]choline PET/CT: validation with surgical specimens.

Authors:  Ralph A Bundschuh; Christina M Wendl; Gregor Weirich; Mathias Eiber; Michael Souvatzoglou; Uwe Treiber; Hubert Kübler; Tobias Maurer; Jürgen E Gschwend; Hans Geinitz; Anca L Grosu; Sibylle I Ziegler; Bernd Joachim Krause
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-02-07       Impact factor: 9.236

Review 7.  New horizons in prostate cancer imaging.

Authors:  Gregory Ravizzini; Baris Turkbey; Karen Kurdziel; Peter L Choyke
Journal:  Eur J Radiol       Date:  2008-11-07       Impact factor: 3.528

Review 8.  Functional imaging for prostate cancer: therapeutic implications.

Authors:  Carina Mari Aparici; Youngho Seo
Journal:  Semin Nucl Med       Date:  2012-09       Impact factor: 4.446

Review 9.  Positron emission tomography in imaging evaluation of staging, restaging, treatment response, and prognosis in prostate cancer.

Authors:  Hossein Jadvar
Journal:  Abdom Radiol (NY)       Date:  2016-05

10.  [(11)C]choline uptake with PET/CT for the initial diagnosis of prostate cancer: relation to PSA levels, tumour stage and anti-androgenic therapy.

Authors:  Giampiero Giovacchini; Maria Picchio; Elisa Coradeschi; Vincenzo Scattoni; Valentino Bettinardi; Cesare Cozzarini; Massimo Freschi; Ferruccio Fazio; Cristina Messa
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-01-16       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.