Evaluation of a new set of calibration standards for the measurement of fat content via DPA and DXA.

M M Goodsitt1.   

Abstract

A simulation study was performed to evaluate a new set of calibration standards for estimating the fat content of the body via dual-photon absorptiometry (DPA) and dual-energy x-ray absorptiometry (DXA). The standards, proposed by Nord and Payne [presented at the 2nd meeting of The Bath Conference on Bone Mineral Measurement (1990)] consist of stearic acid (100% fat) and 0.6% NaCl in water (100% lean). They were compared with other standards consisting of average composition adipose/muscle tissues and fatty adipose/lean muscle tissues. Source and detector properties of a Gd-153 DPA system and three commercial DXA systems were modeled. For each system and calibration set, rms errors in the calculated fat contents of simulated tissues having fat mass percentages that ranged from about 4%-44% and thicknesses that ranged from 5-20 cm were determined. Beam hardening errors for the systems were evaluated as was a calibration technique employed by one of the manufacturers to correct for such errors. In general, the smallest rms errors (2% or less when the calibration standards and tissues were of equal thickness) were obtained with the average adipose/muscle standards. Equivalent results were obtained with standards consisting of stearic acid and 0.8% NaCl. The latter is a higher salt content than proposed by Nord and Payne and results from differences in the x-ray attenuation coefficients that were employed in calculating the fat equivalence of water. Other, more convenient standards, such as lucite and water may be employed by using appropriate fat equivalences (approximately 69% for lucite and approximately 10% for water). Beam hardening errors for the DXA systems are considerable, and the simulated correction technique was shown to be effective.

Entities:  

Mesh:

Year:  1992        PMID: 1620056     DOI: 10.1118/1.596890

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  10 in total

1.  Accuracy and the influence of marrow fat on quantitative CT and dual-energy X-ray absorptiometry measurements of the femoral neck in vitro.

Authors:  J W Kuiper; C van Kuijk; J L Grashuis; A G Ederveen; H E Schütte
Journal:  Osteoporos Int       Date:  1996       Impact factor: 4.507

Review 2.  Imaging approaches to understand disease complexity: chronic obstructive pulmonary disease as a clinical model.

Authors:  Karin J C Sanders; Samuel Y Ash; George R Washko; Felix M Mottaghy; Annemie M W J Schols
Journal:  J Appl Physiol (1985)       Date:  2017-07-27

3.  Bone mineral and body fat measurements by two absorptiometry systems: comparisons with neutron activation analysis.

Authors:  R N Pierson; J Wang; J C Thornton; D P Kotler; S B Heymsfield; D A Weber; R M Ma
Journal:  Calcif Tissue Int       Date:  1995-02       Impact factor: 4.333

4.  Mass attenuation coefficients, quantities and units for use in bone mineral determinations.

Authors:  R Jonson
Journal:  Osteoporos Int       Date:  1993-03       Impact factor: 4.507

5.  Reproducibility and accuracy of body composition assessments in mice by dual energy x-ray absorptiometry and time domain nuclear magnetic resonance.

Authors:  Solveig Halldorsdottir; Jill Carmody; Carol N Boozer; Charles A Leduc; Rudolph L Leibel
Journal:  Int J Body Compos Res       Date:  2009

6.  Predicting visceral adipose tissue by MRI using DXA and anthropometry in adolescents and young adults.

Authors:  Deepika R Laddu; Vinson R Lee; Robert M Blew; Tetsuya Sato; Timothy G Lohman; Scott B Going
Journal:  Int J Body Compos Res       Date:  2012

7.  Validity of leg-to-leg bioelectrical impedance analysis to estimate body fat in obesity.

Authors:  Célia Lloret Linares; Cécile Ciangura; Jean-Luc Bouillot; Muriel Coupaye; Xavier Declèves; Christine Poitou; Arnaud Basdevant; Jean-Michel Oppert
Journal:  Obes Surg       Date:  2011-07       Impact factor: 4.129

8.  Accuracy of DXA in estimating body composition changes in elite athletes using a four compartment model as the reference method.

Authors:  Diana A Santos; Analiza M Silva; Catarina N Matias; David A Fields; Steven B Heymsfield; Luís B Sardinha
Journal:  Nutr Metab (Lond)       Date:  2010-03-22       Impact factor: 4.169

9.  Comparison of bioimpedance spectroscopy and dual energy X-ray absorptiometry for assessing body composition changes in obese children during weight loss.

Authors:  Eline Vermeiren; Marijke Ysebaert; Kim Van Hoorenbeeck; Luc Bruyndonckx; Kristof Van Dessel; Maria Van Helvoirt; Ann De Guchtenaere; Benedicte De Winter; Stijn Verhulst; Annelies Van Eyck
Journal:  Eur J Clin Nutr       Date:  2020-09-11       Impact factor: 4.016

10.  Body composition measured by dual-energy X-ray absorptiometry half-body scans in obese adults.

Authors:  Megan P Rothney; Robert J Brychta; Emily V Schaefer; Kong Y Chen; Monica C Skarulis
Journal:  Obesity (Silver Spring)       Date:  2009-02-19       Impact factor: 5.002

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.