Literature DB >> 16184613

A simplified flow cytometry method of CD4 and CD8 cell counting based on thermoresistant reagents: implications for large scale monitoring of HIV-infected patients in resource-limited settings.

Silva Barbesti1, Laura Soldini, Guisline Carcelain, Angelique Guignet, Vittorio Colizzi, Barbara Mantelli, Alessandro Corvaglia, Thun Tran-Minh, Fernanda Dorigatti, Brigitte Autran, Adriano Lazzarin, Alberto Beretta.   

Abstract

OBJECTIVE: To validate a simplified flow cytometry assay for CD4 and CD8 T cell counting based on monoclonal antibodies which are made resistant to high temperatures (simplified thermoresistant assay (STRA)).
METHOD: The STRA employs FITC-conjugated anti-CD4 and anti-CD8 monoclonal antibodies, predispensed into test tubes and chemically treated to be resistant to high temperatures. Five correlation studies were performed in three different laboratories on a total of 560 blood samples from HIV-1 infected patients. Each study correlated the STRA with either double or single platform assays currently available. Accelerated stability tests on the FITC-conjugated monoclonal antibodies were performed to assess the resistance of the STRA to high temperatures.
RESULTS: Comparison of STRA with both single platform and double platform assays gave correlation coefficients ranging 0.957-0.987 for CD4+ T cells and 0.946-0.968 for CD8+ T cells. In all correlation studies there was a perfect data overlapping in the low-pathological interval of CD4+ T cells (0-400 cells/ml). The FITC-conjugated CD4 and CD8 monoclonal antibodies maintained intact binding activity and fluorescence brightness after storage for 4 weeks at 45 degrees C and can be stored for up to 8 years in regular conditions (+4 degrees C).
CONCLUSIONS: The STRA correlates well with both single-platform and double-platform flow-cytometry assays currently used to assess CD4+ T cells. The test procedure is simple, rapid, and easy to perform. The reagents can be stored under unfavorable environmental conditions for long period of time. These features should facilitate access to flow cytometry testing in resource-poor settings. (c) 2005 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16184613     DOI: 10.1002/cyto.b.20068

Source DB:  PubMed          Journal:  Cytometry B Clin Cytom        ISSN: 1552-4949            Impact factor:   3.058


  11 in total

1.  Validation of a single-platform, volumetric, CD45-assisted PanLeucogating Auto40 flow cytometer to determine the absolute number and percentages of CD4 T cells in resource-constrained settings using Cameroonian patients' samples.

Authors:  François-Xavier Mbopi-Kéou; Stefano Mion; Bertrand Sagnia; Laurent Bélec
Journal:  Clin Vaccine Immunol       Date:  2012-02-15

2.  Fermentation profile of Saccharomyces cerevisiae and Candida tropicalis as starter cultures on barley malt medium.

Authors:  Wazé Aimée Mireille Alloue-Boraud; Kouadio Florent N'Guessan; N'Dédé Théodore Djeni; Serge Hiligsmann; Koffi Marcellin Djè; Franck Delvigne
Journal:  J Food Sci Technol       Date:  2014-08-31       Impact factor: 2.701

3.  Validation of a single-platform, volumetric, flow cytometry for CD4 T cell count monitoring in therapeutic mobile unit.

Authors:  François-Xavier Mbopi-Kéou; Bertrand Sagnia; Jeanne Ngogang; Fru F Angwafo; Vittorio Colizzi; Luc Montagnier; Laurent Bélec
Journal:  J Transl Med       Date:  2012-02-06       Impact factor: 5.531

4.  Ligand engagement of Toll-like receptors regulates their expression in cortical microglia and astrocytes.

Authors:  Carla Marinelli; Rosa Di Liddo; Laura Facci; Thomas Bertalot; Maria Teresa Conconi; Morena Zusso; Stephen D Skaper; Pietro Giusti
Journal:  J Neuroinflammation       Date:  2015-12-30       Impact factor: 8.322

5.  Phage-Based Fluorescent Biosensor Prototypes to Specifically Detect Enteric Bacteria Such as E. coli and Salmonella enterica Typhimurium.

Authors:  Manon Vinay; Nathalie Franche; Gérald Grégori; Jean-Raphaël Fantino; Flavie Pouillot; Mireille Ansaldi
Journal:  PLoS One       Date:  2015-07-17       Impact factor: 3.240

6.  CD4 T-cell immune stimulation of HER2 + breast cancer cells alters response to trastuzumab in vitro.

Authors:  Patrick N Song; Ameer Mansur; Kari J Dugger; Tessa R Davis; Grant Howard; Thomas E Yankeelov; Anna G Sorace
Journal:  Cancer Cell Int       Date:  2020-11-10       Impact factor: 5.722

7.  Single-platform, volumetric, CD45-assisted pan-leucogating flow cytometry for CD4 T lymphocytes monitoring of HIV infection according to the WHO recommendations for resource-constrained settings.

Authors:  Donato Koyalta; Mohammad-Ali Jenabian; Ngamasra Nadjiouroum; Barou Djouater; Noël Djemadji-Oudjeil; Angélique Ndjoyi-Mbiguino; Laurent Bélec
Journal:  BMC Res Notes       Date:  2013-04-30

8.  Field evaluation in Chad of community usage of CD4 T lymphocyte counting by alternative single-platform flow cytometry.

Authors:  Donato Koyalta; Mohammad-Ali Jenabian; Barou Djouater; Noël Djemadji-Oudjeil; Francois-Xavier Mbopi-Keou; Angélique Ndjoyi-Mbiguino; Laurent Bélec
Journal:  BMC Health Serv Res       Date:  2013-10-01       Impact factor: 2.655

9.  Interferon-γ release assay as a sensitive diagnostic tool of latent tuberculosis infection in patients with HIV: a cross-sectional study.

Authors:  Giselle Burlamaqui Klautau; Nadijane Valéria Ferreira da Mota; Mauro José Costa Salles; Marcelo Nascimento Burattini; Denise Silva Rodrigues
Journal:  BMC Infect Dis       Date:  2018-11-19       Impact factor: 3.090

10.  Activation and degranulation of CAR-T cells using engineered antigen-presenting cell surfaces.

Authors:  Qassim Dirar; Teal Russell; Lumei Liu; Sarah Ahn; Gianpietro Dotti; Shyam Aravamudhan; Laura Conforti; Yeoheung Yun
Journal:  PLoS One       Date:  2020-09-25       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.