PURPOSE: To analyze the tolerance dose for retention of visual acuity in patients with head-and-neck tumors treated with carbon ion radiotherapy. METHODS AND MATERIALS: From June 1994 to March 2000, 163 patients with tumors in the head and neck or skull base region were treated with carbon ion radiotherapy. Analysis was performed on 54 optic nerves (ONs) corresponding to 30 patients whose ONs had been included in the irradiated volume. These patients showed no evidence of visual impairment due to other factors and had a follow-up period of >4 years. All patients had been informed of the possibility of visual impairment before treatment. We evaluated the dose-complication probability and the prognostic factors for the retention of visual acuity in carbon ion radiotherapy, using dose-volume histograms and multivariate analysis. RESULTS: The median age of 30 patients (14 men, 16 women) was 57.2 years. Median prescribed total dose was 56.0 gray equivalents (GyE) at 3.0-4.0 GyE per fraction per day (range, 48-64 GyE; 16-18 fractions; 4-6 weeks). Of 54 ONs that were analyzed, 35 had been irradiated with <57 GyE (maximum dose [Dmax]) resulting in no visual loss. Conversely, 11 of the 19 ONs (58%) irradiated with >57 GyE (Dmax) suffered a decrease of visual acuity. In all of these cases, the ONs had been involved in the tumor before carbon ion radiotherapy. In the multivariate analysis, a dose of 20% of the volume of the ON (D20) was significantly associated with visual loss. CONCLUSIONS: The occurrence of visual loss seems to be correlated with a delivery of >60 GyE to 20% of the volume of the ON.
PURPOSE: To analyze the tolerance dose for retention of visual acuity in patients with head-and-neck tumors treated with carbon ion radiotherapy. METHODS AND MATERIALS: From June 1994 to March 2000, 163 patients with tumors in the head and neck or skull base region were treated with carbon ion radiotherapy. Analysis was performed on 54 optic nerves (ONs) corresponding to 30 patients whose ONs had been included in the irradiated volume. These patients showed no evidence of visual impairment due to other factors and had a follow-up period of >4 years. All patients had been informed of the possibility of visual impairment before treatment. We evaluated the dose-complication probability and the prognostic factors for the retention of visual acuity in carbon ion radiotherapy, using dose-volume histograms and multivariate analysis. RESULTS: The median age of 30 patients (14 men, 16 women) was 57.2 years. Median prescribed total dose was 56.0 gray equivalents (GyE) at 3.0-4.0 GyE per fraction per day (range, 48-64 GyE; 16-18 fractions; 4-6 weeks). Of 54 ONs that were analyzed, 35 had been irradiated with <57 GyE (maximum dose [Dmax]) resulting in no visual loss. Conversely, 11 of the 19 ONs (58%) irradiated with >57 GyE (Dmax) suffered a decrease of visual acuity. In all of these cases, the ONs had been involved in the tumor before carbon ion radiotherapy. In the multivariate analysis, a dose of 20% of the volume of the ON (D20) was significantly associated with visual loss. CONCLUSIONS: The occurrence of visual loss seems to be correlated with a delivery of >60 GyE to 20% of the volume of the ON.
Authors: Alexandra D Jensen; Anna V Nikoghosyan; Swantje Ecker; Malte Ellerbrock; Jürgen Debus; Marc W Münter Journal: Radiat Oncol Date: 2011-04-05 Impact factor: 3.481
Authors: Piero Fossati; Ana Perpar; Markus Stock; Petra Georg; Antonio Carlino; Joanna Gora; Giovanna Martino; Eugen B Hug Journal: Int J Part Ther Date: 2021-06-25