High-resolution imager for digital mammography: physical characterization of a prototype sensor.

Sankararaman Suryanarayanan1, Andrew Karellas, Srinivasan Vedantham, Steven K Onishi.   

Abstract

The physical performance characteristics of a high-resolution sensor module for digital mammography were investigated. The signal response of the imager was measured at various detector entrance air kerma and was found to be linear. The spatial resolution was determined by measuring the presampling modulation transfer function, MTF(f), of the system. The noise power spectra, NPS(f), of the system were estimated using 26 kVp: Mo/Mo, 28 kVp: Mo/Rh and 30 kVp: Rh/Rh, with polymethyl methacrylate (PMMA) 'tissue equivalent material' of thickness 20, 45 and 57 mm for each of three x-ray spectra at detector entrance air kerma in the range between approximately 80.2 and 92.3 microGy. The noise equivalent quanta, NEQ(f), and detective quantum efficiencies, DQE(f), for the various spectral conditions were computed. In addition, dose dependence of NPS(f) and DQE(f) was studied at various detector entrance air kerma ranging from 9.4 to 169.7 microGy. A spatial resolution of about 10 cycles mm(-1) was obtained at the 10% MTF(f) level. A small increase in NEQ(f)was observed under higher energy spectral conditions while the DQE(f) decreased marginally. For a given spectrum, increasing PMMA filtration produced negligible change in DQE(f). The estimated DQE values at zero frequency were in the range between 0.45 and 0.55 under the conditions investigated in this study.

Entities:  

Mesh:

Year:  2005        PMID: 16177523     DOI: 10.1088/0031-9155/50/17/003

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Detection of simulated microcalcifications in a phantom with digital mammography: effect of pixel size.

Authors:  Sankararaman Suryanarayanan; Andrew Karellas; Srinivasan Vedantham; Ioannis Sechopoulos; Carl J D'Orsi
Journal:  Radiology       Date:  2007-05-23       Impact factor: 11.105

2.  Photon-counting hexagonal pixel array CdTe detector: Spatial resolution characteristics for image-guided interventional applications.

Authors:  Srinivasan Vedantham; Suman Shrestha; Andrew Karellas; Linxi Shi; Matthew J Gounis; Ronaldo Bellazzini; Gloria Spandre; Alessandro Brez; Massimo Minuti
Journal:  Med Phys       Date:  2016-05       Impact factor: 4.071

3.  Study of DQE dependence with beam quality on GE essential mammography flat panel.

Authors:  Rafael García-Mollá; Rafael Linares; Rafael Ayala
Journal:  J Appl Clin Med Phys       Date:  2010-11-25       Impact factor: 2.102

4.  Figure of image quality and information capacity in digital mammography.

Authors:  Christos M Michail; Nektarios E Kalyvas; Ioannis G Valais; Ioannis P Fudos; George P Fountos; Nikos Dimitropoulos; Grigorios Koulouras; Dionisis Kandris; Maria Samarakou; Ioannis S Kandarakis
Journal:  Biomed Res Int       Date:  2014-05-08       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.