Clinical performance of a ventricular automatic capture verification algorithm.

Johannes Sperzel1, Charles Kennergren, Mauro Biffi, Mitchell Smith, Marie Knops, Jaswinder Gill, Jean Boland.   

Abstract

BACKGROUND: This study was conducted to evaluate the clinical performance of the ventricular automatic capture feature as implemented in the Insignia I Ultra pacemaker system (Guidant) utilizing a variety of ventricular leads. Currently, the optimal programming of the pacemaker output considers both pacemaker efficiency (prolonging battery longevity) and patient safety (adequate safety margin). The ability of a pacemaker to automatically adjust the ventricular output above the pacing threshold while maintaining the appropriate safety margin has been explored since the early 1970s and is only available today in conjunction with a specific low polarization lead system.
METHODS: One hundred and five patients were enrolled from 17 European centers utilizing 31 different types of ventricular leads were followed through their 3-month follow-up visit. There were no restrictions on the type of ventricular leads used.
RESULTS: The average mean difference between the commanded autothreshold test (0.652 + 0.335 V) and the manual threshold test (0.651 + 0.335 V) was 0.001 + 0.49 (P < 0.0001). The average mean difference between the ambulatory autothreshold test (0.696 + 0.322 V) and the commanded autothreshold test (0.682 + 0.315 V) was 0.002 + 0.74 (P < 0.0001). Holter recordings confirmed that there were no loss of capture incidences without a backup pulse being delivered. In addition, the mean number of backup pulses delivered in a 24-hour period was less than 0.1% of the total number of paced beats.
CONCLUSIONS: This study provided that the automatic capture feature while using a variety of leads accurately determines the ventricular stimulation threshold and safely delivers a backup pulse when required.

Entities:  

Mesh:

Year:  2005        PMID: 16176532     DOI: 10.1111/j.1540-8159.2005.00196.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  2 in total

Review 1.  Basic Properties And Clinical Applications Of The Intracardiac.

Authors:  Francesco Zanon; Lina Marcantoni; Gianni Pastore; Enrico Baracca; Silvio Aggio; Franco Di Gregorio; Alberto Barbetta; Mauro Carraro; Claudio Picariello; Luca Conte; Loris Roncon
Journal:  J Atr Fibrillation       Date:  2016-12-31

2.  Hemodynamic Surveillance of Ventricular Pacing Effectiveness with the Transvalvular Impedance Sensor.

Authors:  Valeria Calvi; Giovanni Pizzimenti; Marco Lisi; Giuseppe Doria; Ludovico Vasquez; Francesco Lisi; Salvatore Felis; Donatella Tempio; Alfredo Virgilio; Alberto Barbetta; Franco Di Gregorio
Journal:  Adv Med       Date:  2014-08-04
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.