Retention of luting agents on implant abutments of different height and taper.

Mario Bresciano1, Gianmario Schierano, Carlo Manzella, Antonio Screti, Cristina Bignardi, Giulio Preti.   

Abstract

OBJECTIVE: The purpose of this study was to evaluate the retention of four cements used to lute metal restorations onto computer designed and manufactured titanium implant abutments of different heights and convergence angles.
MATERIAL AND METHODS: Test specimens consisted of metal coping cemented on Procera titanium abutments of 5, 7, and 9 mm of height, and of 0 degrees , 4 degrees , and 8 degrees of convergence angle. The cements used were zinc-phosphate, zinc oxide-eugenole, polyurethane resin with and without vaseline. The samples were tested in a universal testing machine. The mean uniaxial load at point of separation was determined. The results were statistically evaluated with ANOVA.
RESULTS: The luting agent, the height, and the taper influence the retention of metal casting on customized CAD-CAM implant abutments.
CONCLUSION: The most retentive cement was zinc-phosphate, followed by polyurethane, polyurethane plus vaseline, and zinc oxide-eugenol.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16164467     DOI: 10.1111/j.1600-0501.2005.01159.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  15 in total

1.  The influence of implant abutment surface roughness and the type of cement on retention of implant supported crowns.

Authors:  S Varalakshmi Reddy; M Sushender Reddy; C Rajaneesh Reddy; Padmaja Pithani; Santosh Kumar R; Ganesh Kulkarni
Journal:  J Clin Diagn Res       Date:  2015-03-01

2.  Comparison of the effect of implant abutment surface modifications on retention of implant-supported restoration with a polymer based cement.

Authors:  Nabaprakash Sahu; Namratha Lakshmi; N S Azhagarasan; Yoshaskam Agnihotri; Manoj Rajan; Ramasubramanian Hariharan
Journal:  J Clin Diagn Res       Date:  2014-01-12

3.  The selection criteria of temporary or permanent luting agents in implant-supported prostheses: in vitro study.

Authors:  Angel Alvarez-Arenal; Ignacio Gonzalez-Gonzalez; Hector deLlanos-Lanchares; Aritza Brizuela-Velasco; Joseba Ellacuria-Echebarria
Journal:  J Adv Prosthodont       Date:  2016-04-21       Impact factor: 1.904

4.  Effect of Surface Modifications on the Retention of Cement-retained Implant Crowns under Fatigue Loads: An In vitro Study.

Authors:  R Ajay; K Suma; Seyed Asharaf Ali; Jambai Sampath Kumar Sivakumar; V Rakshagan; V Devaki; K Divya
Journal:  J Pharm Bioallied Sci       Date:  2017-11

5.  Influence of abutment design on retention of metal copings cemented to implants.

Authors:  Albano Porto da Cunha; Glauco Pereira Moysés; Ana Christina Claro Neves; Rafael Pino Vitti; Flávia Cardoso da Rosa Goulart; Laís Regiane da Siva-Concílio
Journal:  Acta Biomater Odontol Scand       Date:  2016-01-26

6.  Modified Glass Ionomer Cement with "Remove on Demand" Properties: An In Vitro Study.

Authors:  Shaza Bishti; Taskin Tuna; Garima Agrawal; Andrij Pich; Stefan Wolfart
Journal:  Dent J (Basel)       Date:  2017-01-23

7.  Effects of abutment diameter, luting agent type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutments.

Authors:  Sina Safari; Fereshteh Hosseini Ghavam; Parviz Amini; Kaveh Yaghmaei
Journal:  J Adv Prosthodont       Date:  2018-02-12       Impact factor: 1.904

8.  Reliability, Learnability and Efficiency of Two Tools for Cement Crowns Retrieval in Dentistry.

Authors:  Cristina Bignardi; Elisabetta M Zanetti; Mara Terzini; Anna R Ciccola; Gianmario Schierano; Alberto L Audenino
Journal:  Open Biomed Eng J       Date:  2018-06-29

9.  Evaluation of removal forces of implant-supported zirconia copings depending on abutment geometry, luting agent and cleaning method during re-cementation.

Authors:  Matthias Rödiger; Sven Rinke; Fenja Ehret-Kleinau; Franziska Pohlmeyer; Katharina Lange; Ralf Bürgers; Nikolaus Gersdorff
Journal:  J Adv Prosthodont       Date:  2014-06-24       Impact factor: 1.904

10.  Retention Strength after Compressive Cyclic Loading of Five Luting Agents Used in Implant-Supported Prostheses.

Authors:  Angel Alvarez-Arenal; Ignacio Gonzalez-Gonzalez; Hector deLlanos-Lanchares; Aritza Brizuela-Velasco; Javier Pinés-Hueso; Joseba Ellakuria-Echebarria
Journal:  Biomed Res Int       Date:  2016-10-16       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.