Literature DB >> 16162099

Preoperative evaluation of living kidney donors using multirow detector computed tomography: comparison with digital subtraction angiography and intraoperative findings.

Enrique Lopez Hänninen1, Timm Denecke, Lars Stelter, Maciej Pech, Petr Podrabsky, Johann Pratschke, Jens Ricke, Ralf Schindler, Peter Neuhaus, Ronald Felix, Stefan G Tullius, Stefen G Tullius.   

Abstract

To assess the accuracy of multirow detector computed tomography (MDCT) for the evaluation of renal anatomy for preoperative donor assessment in living related kidney transplantation. MDCT-scans (4- and 16-slice-CT) of 51 consecutive living kidney donors (age, 51.6 +/- 9.7 years; range, 28-68 years) were analysed by three blinded observers and compared with digital subtraction angiography (DSA) and surgery. Contrast-enhanced MDCT was performed with 1 mm slice thickness reconstruction interval during arterial and venous phases. Supernumerary renal arteries, veins, early branching of vessels and abnormalities of the ureters were documented. The overall accuracy of computed tomography angiography (CTA) for detection and classification of surgically relevant arterial variants was 97% (99/102). The interpretation of 16-channel MDCT images was correct in all cases (accuracy, 100%), while the four-channel CTA had three incorrect results regarding the differentiation of early branching vessels from double renal arteries (accuracy, 93%). The overall accuracy of DSA was 91%. Renal vein abnormalities were correctly diagnosed with MDCT in 100% compared with 89% correct findings with DSA. There were three kidneys with incomplete ureter duplication, detected both with MDCT and DSA. MDCT demonstrated superior accuracy compared with non-selective DSA for the preoperative assessment of renal anatomy in living kidney donors; and for the distinction of supernumerary arteries versus early branching patterns, 16-channel CTA data were better than those of the four-channel system.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16162099     DOI: 10.1111/j.1432-2277.2005.00196.x

Source DB:  PubMed          Journal:  Transpl Int        ISSN: 0934-0874            Impact factor:   3.782


  10 in total

1.  Measurement of renal function in a kidney donor: a comparison of creatinine-based and volume-based GFRs.

Authors:  Don Kyoung Choi; See Min Choi; Bong Hee Park; Byong Chang Jeong; Seong Il Seo; Seong Soo Jeon; Hyun Moo Lee; Han-Yong Choi; Hwang Gyun Jeon
Journal:  Eur Radiol       Date:  2015-05-08       Impact factor: 5.315

2.  [Analysis of 64-row multidetector CT images for preoperative angiographic evaluation of potential living kidney donors].

Authors:  D Blondin; K Andersen; P Kroepil; M Cohnen; U Mödder; W Sandmann; K Ivens; G Jung
Journal:  Radiologe       Date:  2008-07       Impact factor: 0.635

3.  Multidetector CT angiography of renal vasculature: normal anatomy and variants.

Authors:  Aysel Türkvatan; Mustafa Ozdemir; Turhan Cumhur; Tülay Olçer
Journal:  Eur Radiol       Date:  2008-07-30       Impact factor: 5.315

4.  Multidetector computed tomography for preoperative assessment of hepatic vasculature and prediction of splenic artery steal syndrome in patients with liver cirrhosis before transplantation.

Authors:  Christian Grieser; Timm Denecke; Ingo G Steffen; Maria Avgenaki; Vera Fröhling; Martina Mogl; Dirk Schnapauff; Lukas Lehmkuhl; Lars Stelter; Florian Streitparth; Jan Langrehr; Jan-Holger Rothe; Bernd Hamm; Enrique Lopez Hänninen
Journal:  Eur Radiol       Date:  2009-08-07       Impact factor: 5.315

5.  One-stop preoperative assessment of renal vessels for living donors with 3.0 T non-contrast-enhanced magnetic resonance angiography: compared with computerized tomography angiography and surgical results.

Authors:  Xiaotian Li; Fangjie Xia; Lihua Chen; Xiaodong Zhang; Chunbai Mo; Wen Shen
Journal:  Br J Radiol       Date:  2021-10-05       Impact factor: 3.039

6.  Multidetector computed tomography for preoperative evaluation of vascular anatomy in living renal donors.

Authors:  Aysel Türkvatan; Serkan Akinci; Sener Yildiz; Tülay Olçer; Turhan Cumhur
Journal:  Surg Radiol Anat       Date:  2008-10-25       Impact factor: 1.246

7.  Evaluating potential live-renal donors: Causes for rejection, deferral and planned procedure type, a single-centre experience.

Authors:  Nathan Perlis; Maureen Connelly; John R D'A Honey; Kenneth T Pace; Robert Stewart
Journal:  Can Urol Assoc J       Date:  2013 Jan-Feb       Impact factor: 1.862

8.  Minimum intensity projections of the biliary system using 16-channel multidetector computed tomography in patients with biliary obstruction: comparison with MRCP.

Authors:  Timm Denecke; Erika Degutyte; Lars Stelter; Lukas Lehmkuhl; Ray Valencia; Enrique Lopez-Hänninen; Roland Felix; Christian Stroszczynski
Journal:  Eur Radiol       Date:  2006-03-03       Impact factor: 5.315

9.  Role of multidetector computed tomography for evaluation of living kidney donors.

Authors:  Baratali Asghari; Mansour Babaei; Bijan Pakroshan; Alireza Vaziriniya; Abdolreza Babamahmoodi
Journal:  Nephrourol Mon       Date:  2013-08-12

10.  Impact of grafting using thin upper pole artery ligation on living-donor adult kidney transplantation: The STROBE study.

Authors:  Takahisa Hiramitsu; Manabu Okada; Kenta Futamura; Takayuki Yamamoto; Makoto Tsujita; Norihiko Goto; Shunji Narumi; Yoshihiko Watarai
Journal:  Medicine (Baltimore)       Date:  2016-10       Impact factor: 1.889

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.