Literature DB >> 1616161

Efficacy of the FEF colorimetric end-tidal carbon dioxide detector in children.

J S Kelly1, R D Wilhoit, R E Brown, R James.   

Abstract

Direct laryngoscopy and observation of endotracheal tube (ETT) passage between the vocal cords remain the criterion standard for verifying endotracheal intubation. Detection of end-tidal carbon dioxide (ETCO2) serves as an invaluable adjunct to confirm endotracheal intubation, detect inadvertent esophageal intubation, and monitor for accidental tracheal extubation. Capnography, however, is often unavailable outside the operating suite. A commercially available, disposable, colorimetric ETCO2 detector (FEF, Fenem, Inc., New York, N.Y.), in which color changes using a numerical scale semiquantitatively measure percent carbon dioxide in exhaled gases, has proved effective in confirming endotracheal intubation in adults, but has not been thoroughly investigated in children. We studied 20 otherwise healthy children, aged 6 mo to 8 yr, with simultaneous infrared and colorimetric ETCO2 measurements during elective general anesthesia to evaluate the efficacy of the colorimetric detector. Two hundred of 200 tracheally intubated positive-pressure breaths and 198 of 200 breaths under spontaneous mask ventilation demonstrated a yellow color change (color level 5 or 6), signifying an ETCO2 greater than or equal to 15 mm Hg (2.0 kPa). Repeated-measures analysis of variance revealed no significant differences in infrared ETCO2 values between the two yellow color levels throughout the study period. The associations among color level, infrared ETCO2 determinations, ETT size, and ETT "leak" pressures estimated by Spearman rank correlation analysis were significant only for higher infrared ETCO2 values with higher ETT leak pressures (P less than 0.05). No complications were observed. The Fenem disposable colorimetric ETCO2 detector effectively confirms clinical signs of endotracheal intubation in children when capnography is unavailable.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1616161

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  5 in total

1.  Part 10: Pediatric basic and advanced life support: 2010 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science With Treatment Recommendations.

Authors:  Monica E Kleinman; Allan R de Caen; Leon Chameides; Dianne L Atkins; Robert A Berg; Marc D Berg; Farhan Bhanji; Dominique Biarent; Robert Bingham; Ashraf H Coovadia; Mary Fran Hazinski; Robert W Hickey; Vinay M Nadkarni; Amelia G Reis; Antonio Rodriguez-Nunez; James Tibballs; Arno L Zaritsky; David Zideman
Journal:  Circulation       Date:  2010-10-19       Impact factor: 29.690

2.  Pediatric basic and advanced life support: 2010 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science with Treatment Recommendations.

Authors:  Monica E Kleinman; Allan R de Caen; Leon Chameides; Dianne L Atkins; Robert A Berg; Marc D Berg; Farhan Bhanji; Dominique Biarent; Robert Bingham; Ashraf H Coovadia; Mary Fran Hazinski; Robert W Hickey; Vinay M Nadkarni; Amelia G Reis; Antonio Rodriguez-Nunez; James Tibballs; Arno L Zaritsky; David Zideman
Journal:  Pediatrics       Date:  2010-10-18       Impact factor: 7.124

3.  Monitoring oxygenation and ventilation during magnetic resonance imaging: a pictorial essay.

Authors:  C Bell; A H Conte
Journal:  J Clin Monit       Date:  1996-01

Review 4.  Carbon dioxide kinetics and capnography during critical care.

Authors:  C T Anderson; P H Breen
Journal:  Crit Care       Date:  2000-07-12       Impact factor: 9.097

Review 5.  Non-invasive carbon dioxide monitoring in neonates: methods, benefits, and pitfalls.

Authors:  Deepika Sankaran; Lida Zeinali; Sameeia Iqbal; Praveen Chandrasekharan; Satyan Lakshminrusimha
Journal:  J Perinatol       Date:  2021-06-19       Impact factor: 2.521

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.