3D volume-selective turbo spin echo for carotid artery wall imaging with navigator detection of swallowing.

Lindsey A Crowe1, Jennifer Keegan, Peter D Gatehouse, Raad H Mohiaddin, Anitha Varghese, Karen Symmonds, Timothy M Cannell, Guang Zhong Yang, David N Firmin.   

Abstract

PURPOSE: To improve 3D volume-selective turbo spin echo (TSE) carotid artery wall imaging by incorporating navigators to reduce artifacts caused by swallowing.
MATERIALS AND METHODS: Images were acquired on a Siemens Magnetom Sonata 1.5T scanner. 3D volume-selective TSE scans of the carotid arteries were acquired in six healthy volunteers. A cross-pair navigator placed on the back of the tongue was used to detect swallowing and movement. Two swallowing patterns were tested: 1) a single swallow approximately halfway through the scan time, at the center of k(z), and 2) repeated swallowing as often as possible throughout the scan period. Images were acquired with and without navigators for comparison. Signal intensity in the lumen was quantified for the quality of blood suppression, and the clarity of the vessel wall in the common carotid was ranked by four independent blinded observers.
RESULTS: In general, lower signal intensity was recorded in the lumen, and decreased blurring and ghosting were observed on scans with navigator control. This reduction in lumen signal intensity signifies an improvement in the black-blood imaging technique. The differences likely reflect the improved double inversion/blood suppression efficiency due to cycles being rejected when the heart rate changed at the point of swallowing, or decreased motional blurring/ghosting of tissue when the navigator is used, or a combination of these two effects. A statistical analysis of image quality showed a significant difference between navigated and non-navigated scans as scored by four independent, blinded observers. For both swallowing patterns, the mean score for the navigator images was on average 0.6 greater than that of non-navigator images (on a scoring scale of 0-5, where 0 = no vessel visible, and 5 = good delineation and blood suppression) and P-values for all observers were less than 0.01. Overall, the central swallow scans were scored higher than the repeated swallow scans. One reason for this may be the fact that the heart rate increased on swallowing, and this often lasted for one or two cardiac cycles after the navigator returned to the normal acceptance position. The effect of the increased heart rate after swallowing is likely to have an effect on double inversion blood suppression efficiency. Therefore, the increased amount of heart rate changes with repeated swallowing may have a greater adverse effect, even if the navigator rejects data views during the swallowing motion.
CONCLUSION: The clarity of vessel wall delineation and the apparent efficiency of blood suppression are reduced by swallowing during acquisition. Both motion blurring and quality of blood suppression are factors that can be improved with the use of a navigator accept/reject method. (c) 2005 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2005        PMID: 16161101     DOI: 10.1002/jmri.20424

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  16 in total

1.  Prospective self-gating for swallowing motion: a feasibility study in carotid artery wall MRI using three-dimensional variable-flip-angle turbo spin-echo.

Authors:  Zhaoyang Fan; Sven Zuehlsdorff; Xin Liu; Debiao Li
Journal:  Magn Reson Med       Date:  2011-12-09       Impact factor: 4.668

2.  Free-breathing inner-volume black-blood imaging of the human heart using two-dimensionally selective local excitation at 3 T.

Authors:  Khaled Z Abd-Elmoniem; Christoph Barmet; Matthias Stuber
Journal:  Magn Reson Med       Date:  2011-12-09       Impact factor: 4.668

3.  Carotid intima-media thickness and distensibility measured by MRI at 3 T versus high-resolution ultrasound.

Authors:  Andreas Harloff; Timo Zech; Alex Frydrychowicz; Martin Schumacher; Joachim Schöllhorn; Jürgen Hennig; Cornelius Weiller; Michael Markl
Journal:  Eur Radiol       Date:  2009-02-13       Impact factor: 5.315

4.  Improved black-blood imaging using DANTE-SPACE for simultaneous carotid and intracranial vessel wall evaluation.

Authors:  Yibin Xie; Qi Yang; Guoxi Xie; Jianing Pang; Zhaoyang Fan; Debiao Li
Journal:  Magn Reson Med       Date:  2015-07-08       Impact factor: 4.668

Review 5.  Noncontrast MR angiography: An update.

Authors:  Robert R Edelman; Ioannis Koktzoglou
Journal:  J Magn Reson Imaging       Date:  2018-12-19       Impact factor: 4.813

6.  CINE turbo spin echo imaging.

Authors:  Jason Mendes; Dennis L Parker; Jordan Hulet; Gerald S Treiman; Seong-Eun Kim
Journal:  Magn Reson Med       Date:  2011-06-23       Impact factor: 4.668

Review 7.  Imaging biomarkers of cardiovascular disease.

Authors:  Jinnan Wang; Niranjan Balu; Gador Canton; Chun Yuan
Journal:  J Magn Reson Imaging       Date:  2010-09       Impact factor: 4.813

8.  Dual stack black blood carotid artery CMR at 3T: application to wall thickness visualization.

Authors:  Axel Bornstedt; Mathias Burgmaier; Vinzenz Hombach; Nikolaus Marx; Volker Rasche
Journal:  J Cardiovasc Magn Reson       Date:  2009-11-10       Impact factor: 5.364

9.  Comparison between 2D and 3D high-resolution black-blood techniques for carotid artery wall imaging in clinically significant atherosclerosis.

Authors:  Niranjan Balu; Baocheng Chu; Thomas S Hatsukami; Chun Yuan; Vasily L Yarnykh
Journal:  J Magn Reson Imaging       Date:  2008-04       Impact factor: 4.813

10.  Rigid-body motion correction with self-navigation MRI.

Authors:  Jason Mendes; Eugene Kholmovski; Dennis L Parker
Journal:  Magn Reson Med       Date:  2009-03       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.