Literature DB >> 16160574

Performance of short implants in partial restorations: 3-year follow-up of Osseotite implants.

Ronnie Goené1, Carlo Bianchesi, Markus Hüerzeler, Ricardo Del Lupo, Tiziano Testori, Mithriadade Davarpanah, Ziad Jalbout.   

Abstract

Short-length implants should be at a performance disadvantage because of the more limited surface area with which to resist occlusal forces. Nevertheless, anecdotal observations find many short implants performing well in different restorative conditions. This retrospective, multicenter study seeks to compare formally implant performance based on length. The success of 7 and 8.5-mm Osseotite implants (Implant Innovations, Inc., Palm Beach Gardens, FL) was determined as: absence of mobility; no persistent and/or irreversible signs or symptoms of pain, infection, paresthesia, or violation of the mandibular canal; no evidence of peri-implant radiolucency; and no progressive crestal bone loss. Implant location, restoration type, bone density, and smoking status of the patients were recorded. A total of 188 patients received 311 short Osseotite implants that were placed mostly in soft bone and supported 216 partially edentulous cases in the maxilla or mandible. Most restorations (95.2%) are short-span fixed partial dentures placed in the posterior sextants. During 3 years of follow-up, 13 implants failed, yielding a cumulative success rate of 95.8%. In 9 of these cases, failure occurred before prosthetic loading, and in 4, the patient was a smoker. The overall success rate compares favorably with the available literature for the performance of implants in general, and short implants in particular.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16160574     DOI: 10.1097/01.id.0000173335.90854.d8

Source DB:  PubMed          Journal:  Implant Dent        ISSN: 1056-6163            Impact factor:   2.454


  8 in total

1.  Posterior partially edentulous jaws, planning a rehabilitation with dental implants.

Authors:  Douglas R Monteiro; Emily V F Silva; Eduardo P Pellizzer; Osvaldo Magro Filho; Marcelo C Goiato
Journal:  World J Clin Cases       Date:  2015-01-16       Impact factor: 1.337

Review 2.  Short Implants: New Horizon in Implant Dentistry.

Authors:  Neha Jain; Manisha Gulati; Meenu Garg; Chetan Pathak
Journal:  J Clin Diagn Res       Date:  2016-09-01

3.  Survival rate of short, locking taper implants with a plateau design: a 5-year retrospective study.

Authors:  Kemal Özgür Demiralp; Nihat Akbulut; Sebnem Kursun; Didem Argun; Nilsun Bagis; Kaan Orhan
Journal:  Biomed Res Int       Date:  2015-04-16       Impact factor: 3.411

4.  Survival of immediately versus delayed loaded short implants: A prospective case series study.

Authors:  Joaquin Alvira-González; Erick Díaz-Campos; Maria-Angeles Sánchez-Garcés; Cosme Gay-Escoda
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2015-07-01

5.  Simplifying the Treatment of Bone Atrophy in the Posterior Regions: Combination of Zygomatic and Wide-Short Implants-A Case Report with 2 Years of Follow-Up.

Authors:  Fernanda Faot; Geninho Thomé; Amália Machado Bielemann; Caio Hermann; Ana Cláudia Moreira Melo; Luis Eduardo Marques Padovan; Ivete Aparecida de Mattias Sartori
Journal:  Case Rep Dent       Date:  2016-10-27

6.  Assessing double Acid-etched implants submitted to orthodontic forces and used as prosthetic anchorages in partially edentulous patients.

Authors:  Rugani de Cravero Marta; Ibañez Juan Carlos
Journal:  Open Dent J       Date:  2008-03-08

Review 7.  Short Dental Implants (≤7mm) Versus Longer Implants in Augmented Bone Area: A Meta-Analysis of Randomized Controlled Trials.

Authors:  Priscila N Uehara; Victor Haruo Matsubara; Fernando Igai; Newton Sesma; Marcio K Mukai; Mauricio G Araujo
Journal:  Open Dent J       Date:  2018-04-30

8.  Evaluation of the Surrounding Ring of Two Different Extra-Short Implant Designs in Crestal Bone Maintanence: A Histologic Study in Dogs.

Authors:  José Luis Calvo-Guirado; Hilde Morales-Meléndez; Carlos Pérez-Albacete Martínez; David Morales-Schwarz; Roni Kolerman; Manuel Fernández-Domínguez; Sérgio Alexandre Gehrke; José Eduardo Maté-Sánchez de Val
Journal:  Materials (Basel)       Date:  2018-09-06       Impact factor: 3.623

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.