Automatic tuning of flexible interventional RF receiver coils.

Ross D Venook1, Brian A Hargreaves, Garry E Gold, Steven M Conolly, Greig C Scott.   

Abstract

Microcontroller-based circuitry was built and tested for automatically tuning flexible RF receiver coils at the touch of a button. This circuitry is robust to 10% changes in probe center frequency, is in line with the scanner, and requires less than 1 s to tune a simple probe. Images were acquired using this circuitry with a varactor-tunable 1-inch flexible probe in a phantom and in an in vitro porcine knee model. The phantom experiments support the use of automatic tuning by demonstrating 30% signal-to-noise ratio (SNR) losses for 5% changes in coil center frequency, in agreement with theoretical calculations. Comparisons between patellofemoral cartilage images obtained using a 3-inch surface coil and the surgically-implanted 1-inch flexible coil reveal a worst-case local SNR advantage of a factor of 4 for the smaller coil. This work confirms that surgically implanted coils can greatly improve resolution in small-field-of-view (FOV) applications, and demonstrates the importance and feasibility of automatically tuning such probes. Copyright 2005 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2005        PMID: 16155871     DOI: 10.1002/mrm.20616

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  5 in total

1.  Design of an Electrically Automated RF Transceiver Head Coil in MRI.

Authors:  Sung-Min Sohn; Lance DelaBarre; Anand Gopinath; John Thomas Vaughan
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2014-10-28       Impact factor: 3.833

2.  Ratio-adjustable power splitters for array-compressed parallel transmission.

Authors:  Xinqiang Yan; Zhipeng Cao; William A Grissom
Journal:  Magn Reson Med       Date:  2017-07-31       Impact factor: 4.668

3.  Experimental implementation of array-compressed parallel transmission at 7 tesla.

Authors:  Xinqiang Yan; Zhipeng Cao; William A Grissom
Journal:  Magn Reson Med       Date:  2016-04-15       Impact factor: 4.668

4.  Bench to bore ramifications of inter-subject head differences on RF shimming and specific absorption rates at 7T.

Authors:  Benjamin M Hardy; Rana Banik; Xinqiang Yan; Adam W Anderson
Journal:  Magn Reson Imaging       Date:  2022-07-13       Impact factor: 3.130

Review 5.  RF coils: A practical guide for nonphysicists.

Authors:  Bernhard Gruber; Martijn Froeling; Tim Leiner; Dennis W J Klomp
Journal:  J Magn Reson Imaging       Date:  2018-06-13       Impact factor: 4.813

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.