Literature DB >> 16154422

A new type of model-based Roentgen stereophotogrammetric analysis for solving the occluded marker problem.

B L Kaptein1, E R Valstar, B C Stoel, P M Rozing, J H C Reiber.   

Abstract

Roentgen stereophotogrammetric analysis (RSA) measures micromotion of an orthopaedic implant with respect to its surrounding bone. A problem in RSA is that the markers are sometimes overprojected by the implant itself. This study describes the so-called Marker Configuration Model-based RSA (MCM-based RSA) that is able to measure the pose of a rigid body in situations where less than three markers could be detected in both images of an RSA radiograph. MCM-based RSA is based on fitting a Marker Configuration model (MC-model) to the projection lines from the marker projection positions in the image to their corresponding Roentgen foci. An MC-model describes the positions of markers relative to each other and is obtained using conventional RSA. We used data from 15 double examinations of a clinical study of total knee prostheses and removed projections of the three tibial component markers, simulating occlusion of markers. The migration of the tibial component with respect to the bone, which should be zero, for the double examination is a measure of the accuracy of algorithm. With the new algorithm, it is possible to estimate the pose of a rigid body of which one or two markers are occluded in one of the images of the RSA radiograph with high accuracy as long as a proper MC-model of the markers in the rigid body is available. The new algorithm makes RSA more robust for occlusion of markers. This improves the results of clinical RSA studies because the number of lost RSA follow-up moments is reduced.

Entities:  

Mesh:

Year:  2004        PMID: 16154422     DOI: 10.1016/j.jbiomech.2004.09.018

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  23 in total

1.  Radiostereometric analysis of keeled versus pegged glenoid components in total shoulder arthroplasty: a randomized feasibility study.

Authors:  Trevor C Gascoyne; Sheila M B McRae; Sara L Parashin; Jeff R S Leiter; Martin J Petrak; Eric R Bohm; Peter B MacDonald
Journal:  Can J Surg       Date:  2017-08       Impact factor: 2.089

2.  No difference in terms of radiostereometric analysis between fixed- and mobile-bearing total knee arthroplasty: a randomized, single-blind, controlled trial.

Authors:  M G M Schotanus; P Pilot; B L Kaptein; W F Draijer; P B J Tilman; R Vos; N P Kort
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-04-27       Impact factor: 4.342

3.  Migration pattern of cemented Exeter short stem in Dorr type A femurs. A prospective radiostereometry study with 2-year follow-up.

Authors:  Tobias Dahl Vind; Peter Bo Jørgensen; Dovydas Vainorius; Stig Storgaard Jakobsen; Kjeld Søballe; Maiken Stilling
Journal:  Arch Orthop Trauma Surg       Date:  2022-02-03       Impact factor: 3.067

4.  Comparison of trabecular metal cups and titanium fiber-mesh cups in primary hip arthroplasty: a randomized RSA and bone mineral densitometry study of 50 hips.

Authors:  Thomas Baad-Hansen; Søren Kold; Poul Torben Nielsen; Mogens Berg Laursen; Poul Hedevang Christensen; Kjeld Soballe
Journal:  Acta Orthop       Date:  2011-03-25       Impact factor: 3.717

5.  Continued stabilization of trabecular metal tibial monoblock total knee arthroplasty components at 5 years-measured with radiostereometric analysis.

Authors:  David A J Wilson; Glen Richardson; Allan W Hennigar; Michael J Dunbar
Journal:  Acta Orthop       Date:  2011-12-29       Impact factor: 3.717

6.  Measurement of migration of a humeral head resurfacing prosthesis using radiostereometry without implant marking: an experimental study.

Authors:  Olof Sköldenberg; Magnus Odquist
Journal:  Acta Orthop       Date:  2011-03-24       Impact factor: 3.717

7.  The beneficial effect of hydroxyapatite lasts: a randomized radiostereometric trial comparing hydroxyapatite-coated, uncoated, and cemented tibial components for up to 16 years.

Authors:  Bart G Pijls; Edward R Valstar; Bart L Kaptein; Marta Fiocco; Rob G H H Nelissen
Journal:  Acta Orthop       Date:  2012-02-13       Impact factor: 3.717

8.  Longitudinal migration and inducible displacement of the Mobility Total Ankle System.

Authors:  Michael J Dunbar; Jason W Fong; David A Wilson; Allan W Hennigar; Patricia A Francis; Mark A Glazebrook
Journal:  Acta Orthop       Date:  2012-08-10       Impact factor: 3.717

9.  Dependence of model-based RSA accuracy on higher and lower implant surface model quality.

Authors:  Frank Seehaus; Judith Emmerich; Bart L Kaptein; Henning Windhagen; Christof Hurschler
Journal:  Biomed Eng Online       Date:  2013-04-16       Impact factor: 2.819

10.  Development and validation of an automated and marker-free CT-based spatial analysis method (CTSA) for assessment of femoral hip implant migration: In vitro accuracy and precision comparable to that of radiostereometric analysis (RSA).

Authors:  Thierry Scheerlinck; Mathias Polfliet; Rudi Deklerck; Gert Van Gompel; Nico Buls; Jef Vandemeulebroucke
Journal:  Acta Orthop       Date:  2015-12-03       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.