BACKGROUND: A simplified alternative to the Cox maze procedure to treat atrial fibrillation with epicardial high-intensity focused ultrasound was evaluated clinically, and the initial clinical results were assessed at the 6-month follow-up visit. METHODS: From September 2002 through February 2004, 103 patients were prospectively enrolled in a multicenter study. Atrial fibrillation duration ranged from 6 to 240 months (mean, 44 months) and was permanent in 76 (74%) patients, paroxysmal in 22 (21%) patients, and persistent in 5 (5%) patients. All patients had concomitant operations, and ablation was performed epicardially on the beating heart before the concomitant procedure. The device automatically created a circumferential left atrial ablation around the pulmonary veins in an average of 10 minutes, and an additional mitral line was created epicardially in 35 (34%) patients with a handheld device by using the same technology. RESULTS: No complications or deaths were device or procedure related. There were 4 (3.8%) early deaths and 2 late extracardiac deaths. The 6-month follow-up was complete in all survivors. At the 6-month visit, freedom from atrial fibrillation was 85% in the entire study group (80% in patients with permanent atrial fibrillation, 88% in the 35 patients who had the additional mitral line, and 100% in patients with paroxysmal atrial fibrillation). A pacemaker was implanted in 8 patients. Only the duration and type of atrial fibrillation significantly increased the risk of recurrence. CONCLUSION: Epicardial, off-pump, beating-heart ablation with acoustic energy is safe and cures 80% of patients with permanent atrial fibrillation associated with long-standing structural heart disease.
BACKGROUND: A simplified alternative to the Cox maze procedure to treat atrial fibrillation with epicardial high-intensity focused ultrasound was evaluated clinically, and the initial clinical results were assessed at the 6-month follow-up visit. METHODS: From September 2002 through February 2004, 103 patients were prospectively enrolled in a multicenter study. Atrial fibrillation duration ranged from 6 to 240 months (mean, 44 months) and was permanent in 76 (74%) patients, paroxysmal in 22 (21%) patients, and persistent in 5 (5%) patients. All patients had concomitant operations, and ablation was performed epicardially on the beating heart before the concomitant procedure. The device automatically created a circumferential left atrial ablation around the pulmonary veins in an average of 10 minutes, and an additional mitral line was created epicardially in 35 (34%) patients with a handheld device by using the same technology. RESULTS: No complications or deaths were device or procedure related. There were 4 (3.8%) early deaths and 2 late extracardiac deaths. The 6-month follow-up was complete in all survivors. At the 6-month visit, freedom from atrial fibrillation was 85% in the entire study group (80% in patients with permanent atrial fibrillation, 88% in the 35 patients who had the additional mitral line, and 100% in patients with paroxysmal atrial fibrillation). A pacemaker was implanted in 8 patients. Only the duration and type of atrial fibrillation significantly increased the risk of recurrence. CONCLUSION: Epicardial, off-pump, beating-heart ablation with acoustic energy is safe and cures 80% of patients with permanent atrial fibrillation associated with long-standing structural heart disease.
Authors: Douglas L Miller; Nadine B Smith; Michael R Bailey; Gregory J Czarnota; Kullervo Hynynen; Inder Raj S Makin Journal: J Ultrasound Med Date: 2012-04 Impact factor: 2.153
Authors: Hugh Calkins; Karl Heinz Kuck; Riccardo Cappato; Josep Brugada; A John Camm; Shih-Ann Chen; Harry J G Crijns; Ralph J Damiano; D Wyn Davies; John DiMarco; James Edgerton; Kenneth Ellenbogen; Michael D Ezekowitz; David E Haines; Michel Haissaguerre; Gerhard Hindricks; Yoshito Iesaka; Warren Jackman; Jose Jalife; Pierre Jais; Jonathan Kalman; David Keane; Young-Hoon Kim; Paulus Kirchhof; George Klein; Hans Kottkamp; Koichiro Kumagai; Bruce D Lindsay; Moussa Mansour; Francis E Marchlinski; Patrick M McCarthy; J Lluis Mont; Fred Morady; Koonlawee Nademanee; Hiroshi Nakagawa; Andrea Natale; Stanley Nattel; Douglas L Packer; Carlo Pappone; Eric Prystowsky; Antonio Raviele; Vivek Reddy; Jeremy N Ruskin; Richard J Shemin; Hsuan-Ming Tsao; David Wilber Journal: J Interv Card Electrophysiol Date: 2012-03 Impact factor: 1.900
Authors: Simon Schopka; Christof Schmid; Andreas Keyser; Ariane Kortner; Julia Tafelmeier; Claudius Diez; Leopold Rupprecht; Michael Hilker Journal: J Cardiothorac Surg Date: 2010-05-05 Impact factor: 1.637
Authors: Babak Nazer; Edward P Gerstenfeld; Akiko Hata; Lawrence A Crum; Thomas J Matula Journal: J Interv Card Electrophysiol Date: 2013-12-03 Impact factor: 1.900