Literature DB >> 16150530

Use of an impedance threshold device improves short-term outcomes following out-of-hospital cardiac arrest.

Roger C Thayne1, D Colin Thomas, James D Neville, Anton Van Dellen.   

Abstract

INTRODUCTION: An impedance threshold device (ITD) has been developed for the treatment of cardiac arrest to augment circulation to the heart and brain during cardiopulmonary resuscitation (CPR). The ITD has ventilation timing lights that flash at 12 min(-1) to discourage excessive ventilation rates. HYPOTHESIS: Implementation of the ITD during conventional manual CPR in a large emergency medical services (EMS) system (Staffordshire, UK) is safe, feasible and will improve short-term survival.
METHODS: ITD use was implemented by the Staffordshire Ambulance Trust, which treats 1600 cardiac arrests per year with 90 advanced life support (ALS) units and an average response time of 6.3 min. During training, rescuers learned to use the ventilation timing lights to discourage hyperventilation. Rescuers applied the device after tracheal intubation. They were trained to allow the chest to recoil fully after each compression. Prospective ITD use in adults receiving conventional manual CPR for non-traumatic cardiac arrest was compared to matched historical controls receiving conventional manual CPR without inspiratory impedance. All received similar ALS care. The primary endpoint was admission to the emergency department (ED) alive following cardiac arrest. Chi-square, Fisher's exact and Kolmogorov-Smirnov tests were used for statistical analyses.
RESULTS: Survival (alive upon ED admission) in all patients receiving an ITD (61/181 [34%]) improved by 50% compared to historical controls (180/808 [22%]) (P<0.01). Survival in patients presenting in asystole tripled in the group receiving an ITD (26/76 [34%]) compared with historical controls (39/351 [11%]) (P=0.001). There were no significant adverse events.
CONCLUSIONS: The ITD was used safely and effectively in a large, diverse EMS system and markedly improved short-term survival for adult patients in non-traumatic cardiac arrest.

Entities:  

Mesh:

Year:  2005        PMID: 16150530     DOI: 10.1016/j.resuscitation.2005.05.009

Source DB:  PubMed          Journal:  Resuscitation        ISSN: 0300-9572            Impact factor:   5.262


  10 in total

1.  Use of the impedance threshold device in cardiopulmonary resuscitation.

Authors:  Theano D Demestiha; Ioannis N Pantazopoulos; Theodoros T Xanthos
Journal:  World J Cardiol       Date:  2010-02-26

2.  New strategies for cardiopulmonary resuscitation.

Authors:  Jonas A Cooper; Joshua M Cooper
Journal:  Curr Treat Options Cardiovasc Med       Date:  2008-02

3.  From laboratory science to six emergency medical services systems: New understanding of the physiology of cardiopulmonary resuscitation increases survival rates after cardiac arrest.

Authors:  Tom P Aufderheide; Carly Alexander; Charles Lick; Brent Myers; Laurie Romig; Levon Vartanian; Joseph Stothert; Scott McKnite; Tim Matsuura; Demetris Yannopoulos; Keith Lurie
Journal:  Crit Care Med       Date:  2008-11       Impact factor: 7.598

4.  Sodium nitroprusside enhanced cardiopulmonary resuscitation improves survival with good neurological function in a porcine model of prolonged cardiac arrest.

Authors:  Demetris Yannopoulos; Timothy Matsuura; Jason Schultz; Kyle Rudser; Henry R Halperin; Keith G Lurie
Journal:  Crit Care Med       Date:  2011-06       Impact factor: 7.598

5.  A trial of an impedance threshold device in out-of-hospital cardiac arrest.

Authors:  Tom P Aufderheide; Graham Nichol; Thomas D Rea; Siobhan P Brown; Brian G Leroux; Paul E Pepe; Peter J Kudenchuk; Jim Christenson; Mohamud R Daya; Paul Dorian; Clifton W Callaway; Ahamed H Idris; Douglas Andrusiek; Shannon W Stephens; David Hostler; Daniel P Davis; James V Dunford; Ronald G Pirrallo; Ian G Stiell; Catherine M Clement; Alan Craig; Lois Van Ottingham; Terri A Schmidt; Henry E Wang; Myron L Weisfeldt; Joseph P Ornato; George Sopko
Journal:  N Engl J Med       Date:  2011-09-01       Impact factor: 91.245

Review 6.  Part 7: CPR techniques and devices: 2010 American Heart Association Guidelines for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care.

Authors:  Diana M Cave; Raul J Gazmuri; Charles W Otto; Vinay M Nadkarni; Adam Cheng; Steven C Brooks; Mohamud Daya; Robert M Sutton; Richard Branson; Mary Fran Hazinski
Journal:  Circulation       Date:  2010-11-02       Impact factor: 29.690

7.  Resuscitation Outcomes Consortium (ROC) PRIMED cardiac arrest trial methods part 1: rationale and methodology for the impedance threshold device (ITD) protocol.

Authors:  Tom P Aufderheide; Peter J Kudenchuk; Jerris R Hedges; Graham Nichol; Richard E Kerber; Paul Dorian; Daniel P Davis; Ahamed H Idris; Clifton W Callaway; Scott Emerson; Ian G Stiell; Thomas E Terndrup
Journal:  Resuscitation       Date:  2008-05-19       Impact factor: 5.262

8.  An updated systematic review and meta-analysis on impedance threshold devices in patients undergoing cardiopulmonary resuscitation.

Authors:  G Biondi-Zoccai; A Abbate; G Landoni; A Zangrillo; J L Vincent; F D'Ascenzo; G Frati
Journal:  Heart Lung Vessel       Date:  2014

Review 9.  Oxygenation, ventilation, and airway management in out-of-hospital cardiac arrest: a review.

Authors:  Tomas Henlin; Pavel Michalek; Tomas Tyll; John D Hinds; Milos Dobias
Journal:  Biomed Res Int       Date:  2014-03-03       Impact factor: 3.411

10.  Effectiveness of a Real-Time Ventilation Feedback Device for Guiding Adequate Minute Ventilation: A Manikin Simulation Study.

Authors:  Sejin Heo; Sun Young Yoon; Jongchul Kim; Hye Seung Kim; Kyunga Kim; Hee Yoon; Sung Yeon Hwang; Won Chul Cha; Taerim Kim
Journal:  Medicina (Kaunas)       Date:  2020-06-05       Impact factor: 2.430

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.