Literature DB >> 16148588

Ultrasound biomicroscopy in the subtypes of primary angle closure glaucoma.

Ramanjit Sihota1, Tanuj Dada, Rajkumar Gupta, P Lakshminarayan, Ravindra M Pandey.   

Abstract

PURPOSE: To evaluate the anterior segment parameters in the subtypes of primary angle closure glaucoma (PACG) using ultrasound biomicroscopy.
METHODS: Five groups, each comprising 30 consecutive patients, diagnosed to have subacute PACG, acute PACG, chronic PACG, primary open angle glaucoma (POAG), and healthy controls were included in the present study. All patients underwent slit-lamp biomicroscopy, direct ophthalmoscopy, 90D fundus examination, gonioscopy, applanation tonometry, visual field testing, A-scan biometry, and ultrasound biomicroscopy (UBM). The anterior segment parameters recorded included: trabecular-iris angle, angle opening distance, trabecular ciliary process distance, and the iris thickness among other parameters.
RESULTS: On ultrasound biomicroscopy the trabecular iris angle of control and POAG groups was more than all the subtypes of PACG (P < 0.001). The trabecular iris angle of subacute PACG (P < 0.001) and chronic PACG (P = 0.003) was more than acute PACG. Angle opening distance of controls and POAG group was significantly more than acute PACG and chronic PACG (P < 0.001). The trabecular ciliary process distance of POAG group and controls was more than subacute PACG, acute PACG, and chronic PACG. The trabecular ciliary process distance of subacute PACG (P < 0.001) and chronic PACG (P < 0.001) was more than acute PACG. Eyes with acute PACG had the least iris thickness at the three different positions tested. There was a positive correlation between the anterior chamber angle (trabecular iris angle) and the following parameters: trabecular ciliary process distance, angle opening distance, anterior chamber depth, and the axial length (r = 0.57).
CONCLUSION: Eyes with primary angle closure glaucoma have a thinner iris with a shorter trabecular iris angle, angle opening distance, and trabecular ciliary process distance. The eyes with acute primary angle closure glaucoma have the narrowest angle recess.

Entities:  

Mesh:

Year:  2005        PMID: 16148588     DOI: 10.1097/01.ijg.0000176934.14229.32

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  23 in total

1.  Nd: Yag laser iridotomy in Shaffer-Etienne grade 1 and 2: angle widening in our case studies.

Authors:  Sandra Cinzia Carlesimo; Luigi Di Santo; Pietro Bruni; Aloisa Librando; Antonietta Pompea Falace; Andrea Barbato
Journal:  Int J Ophthalmol       Date:  2015-08-18       Impact factor: 1.779

2.  Anatomical effects of clear lens extraction by phacoemulsification versus trabeculectomy on anterior chamber drainage angle in primary angle-closure glaucoma (PACG) patients.

Authors:  Xiaofei Man; Noel C Y Chan; Nafees Baig; Yolanda Y Y Kwong; Dexter Y L Leung; Felix C H Li; Clement C Y Tham
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-02-03       Impact factor: 3.117

3.  The biometric study in different stages of primary angle-closure glaucoma.

Authors:  Y-Y Chen; Y-Y Chen; S-J Sheu; P Chou
Journal:  Eye (Lond)       Date:  2013-06-21       Impact factor: 3.775

4.  Role of lens vault in subtypes of angle closure in Iranian subjects.

Authors:  S Moghimi; Z Vahedian; N Zandvakil; M Mohammdi; G Fakhraie; N Nassiri; A L Coleman; S Lin
Journal:  Eye (Lond)       Date:  2014-01-10       Impact factor: 3.775

5.  Sectoral variations of iridocorneal angle width and iris volume in Chinese Singaporeans: a swept-source optical coherence tomography study.

Authors:  Tin A Tun; Mani Baskaran; Shamira A Perera; Anita S Chan; Ching-Yu Cheng; Hla M Htoon; Lisandro M Sakata; Carol Y Cheung; Tin Aung
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-04-30       Impact factor: 3.117

6.  Functional evaluation of an iridotomy in primary angle closure eyes.

Authors:  Ramanjit Sihota; Karandeep Rishi; Geetha Srinivasan; Viney Gupta; Tanuj Dada; Kulwant Singh
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-02-19       Impact factor: 3.117

7.  Iris lens distance to predict the risk of intraocular pressure elevation after dark room provocative test.

Authors:  Xiaoli Liu; Yang Zhang; Lue Li; Ailing Bian; Qi Zhou
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-09-12       Impact factor: 3.117

8.  Comparison of ultrasound biomicroscopy and ultrasonographic parameters in eyes with phacomorphic glaucoma and eyes with mature cataract.

Authors:  Sujata Subbiah; Philip A Thomas; C A Nelson Jesudasan
Journal:  Int Ophthalmol       Date:  2016-09-13       Impact factor: 2.031

Review 9.  Quantitative evaluation of anterior segment parameters in the era of imaging.

Authors:  Syril Dorairaj; Jeffrey M Liebmann; Robert Ritch
Journal:  Trans Am Ophthalmol Soc       Date:  2007

Review 10.  High-resolution ultrasound imaging of the eye - a review.

Authors:  Ronald H Silverman
Journal:  Clin Exp Ophthalmol       Date:  2008-12-09       Impact factor: 4.207

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.