Literature DB >> 16148390

Dose measurements near a non-radioactive gold seed using radiographic film.

James C L Chow1, Grigor N Grigorov.   

Abstract

The dose distribution near a non-radioactive gold seed under a 6 MV photon beam was measured using radiographic film, water equivalent bolus and solid water slabs. This type of small seed is typically used as a marker in target positional verification using a portal imager for conformal prostate treatment such as intensity modulated radiation therapy. A stack of three films was placed on top of the seed located on a soft bolus. Solid water slabs were then placed on top of the film. The films were exposed using a small 1x1 cm2 field. Then, using a similar experimental set-up and exposure, another stack of three films was placed under the seed, which was then covered by the soft bolus and solid water slabs. The cross-plane axial beam profiles at different depths, depending on the thickness of the film package, were measured. From the group of beam profiles above and below the seed, the dose distribution along a selected vertical line within the profiles was easily plotted. Compared to the dose with no seed at the isocentre and 5 cm of solid water, there was about a 21% increase in dose at 0.35 mm above the seed. On the other hand, there was about a 22% decrease in dose at the same distance below the seed. The dosimetry of the calibrated film was verified with a MOSFET detector. The change in dose due to the seed by varying the incident beam angles was also measured for this note.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16148390     DOI: 10.1088/0031-9155/50/18/N02

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

1.  Effect of image quality on correlation modeling error using a fiducial marker in a gimbaled linear accelerator.

Authors:  Hideharu Miura; Shuichi Ozawa; Tsubasa Enosaki; Fumika Hosono; Kiyoshi Yamada; Yasushi Nagata
Journal:  Rep Pract Oncol Radiother       Date:  2019-02-25

Review 2.  Fiducial marker guided prostate radiotherapy: a review.

Authors:  Angela G M O'Neill; Suneil Jain; Alan R Hounsell; Joe M O'Sullivan
Journal:  Br J Radiol       Date:  2016-09-23       Impact factor: 3.039

3.  Investigation of dose perturbations and the radiographic visibility of potential fiducials for proton radiation therapy of the prostate.

Authors:  Jessie Y Huang; Wayne D Newhauser; X Ronald Zhu; Andrew K Lee; Rajat J Kudchadker
Journal:  Phys Med Biol       Date:  2011-07-28       Impact factor: 3.609

4.  Assessment of dose perturbations for metal stent in photon and proton radiotherapy plans for hepatocellular carcinoma.

Authors:  Boram Lee; Sungkoo Cho; Hee Chul Park; Sang-Won Kang; Jae-Sung Kim; Jin-Beom Chung
Journal:  Radiat Oncol       Date:  2022-07-16       Impact factor: 4.309

5.  Calcium Phosphate Cement Paste Injection as a Fiducial Marker of Cervical Cancer.

Authors:  Ichiro Ogino; Masakazu Kitagawa; Shigenobu Watanabe; Hiroshi Yoshida; Masaharu Hata
Journal:  In Vivo       Date:  2018 Nov-Dec       Impact factor: 2.155

6.  Increased dose near the skin due to electromagnetic surface beacon transponder.

Authors:  Kang-Hyun Ahn; Ryan Manger; Howard J Halpern; Bulent Aydogan
Journal:  J Appl Clin Med Phys       Date:  2015-05-08       Impact factor: 2.102

7.  Fiducial markers visibility and artefacts in prostate cancer radiotherapy multi-modality imaging.

Authors:  Sarah O S Osman; Emily Russell; Raymond B King; Karen Crowther; Suneil Jain; Cormac McGrath; Alan R Hounsell; Kevin M Prise; Conor K McGarry
Journal:  Radiat Oncol       Date:  2019-12-26       Impact factor: 3.481

8.  4D modeling in a gimbaled linear accelerator by using gold anchor markers.

Authors:  Hideharu Miura; Shuichi Ozawa; Takaaki Matsuura; Atsushi Kawakubo; Fumika Hosono; Kiyoshi Yamada; Yasushi Nagata
Journal:  Rep Pract Oncol Radiother       Date:  2018-03-18

9.  Determination of optimal fiducial marker across image-guided radiation therapy (IGRT) modalities: visibility and artifact analysis of gold, carbon, and polymer fiducial markers.

Authors:  Lydia L Handsfield; Ning J Yue; Jinghao Zhou; Ting Chen; Sharad Goyal
Journal:  J Appl Clin Med Phys       Date:  2012-09-06       Impact factor: 2.102

Review 10.  The Use of Ultrasound Imaging in the External Beam Radiotherapy Workflow of Prostate Cancer Patients.

Authors:  Saskia M Camps; Davide Fontanarosa; Peter H N de With; Frank Verhaegen; Ben G L Vanneste
Journal:  Biomed Res Int       Date:  2018-01-24       Impact factor: 3.411