Literature DB >> 16143560

Sensorless freehand 3D ultrasound in real tissue: speckle decorrelation without fully developed speckle.

Andrew H Gee1, R James Housden, Peter Hassenpflug, Graham M Treece, Richard W Prager.   

Abstract

It has previously been demonstrated that freehand 3D ultrasound can be acquired without a position sensor by measuring the elevational speckle decorrelation from frame to frame. However, this requires that the B-scans contain significant amounts of fully developed speckle. In this paper, we show that this condition is rarely satisfied in scans of real tissue, which instead exhibit fairly ubiquitous coherent scattering. By examining the axial and lateral correlation functions, we propose an heuristic technique to quantify the amount of coherency at each point in the B-scans. This leads to an adapted elevational decorrelation scheme which allows for the coherent scattering. Using the adapted scheme, we demonstrate markedly improved reconstructions of animal tissue in vitro.

Mesh:

Year:  2005        PMID: 16143560     DOI: 10.1016/j.media.2005.08.001

Source DB:  PubMed          Journal:  Med Image Anal        ISSN: 1361-8415            Impact factor:   8.545


  8 in total

1.  Handheld real-time volumetric imaging of the spine: technology development.

Authors:  Mohamed Tiouririne; Sarah Nguyen; John A Hossack; Kevin Owen; F William Mauldin
Journal:  J Med Eng Technol       Date:  2014-03

2.  Using game controller as position tracking sensor for 3D freehand ultrasound imaging.

Authors:  Vei Siang Chan; Farhan Mohamed; Yusman Azimi Yusoff; Dyah Ekashanti Octorina Dewi; Alfiera Anuar; Mohamad Amir Shamsudin; Wey Sheng Mong
Journal:  Med Biol Eng Comput       Date:  2019-10-10       Impact factor: 2.602

3.  Cross-correlation-based image acquisition technique for manually-scanned optical coherence tomography.

Authors:  Adeel Ahmad; Steven G Adie; Eric J Chaney; Utkarsh Sharma; Stephen A Boppart
Journal:  Opt Express       Date:  2009-05-11       Impact factor: 3.894

4.  Robust Tracking of Small Displacements With a Bayesian Estimator.

Authors:  Douglas M Dumont; Brett C Byram
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-10-27       Impact factor: 2.725

5.  Partial Respiratory Motion Compensation for Abdominal Extracorporeal Boiling Histotripsy Treatments With a Robotic Arm.

Authors:  Gilles P L Thomas; Tatiana D Khokhlova; Vera A Khokhlova
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-08-27       Impact factor: 3.267

6.  Calibration of an orientation sensor for freehand 3D ultrasound and its use in a hybrid acquisition system.

Authors:  Richard James Housden; Graham M Treece; Andrew H Gee; Richard W Prager
Journal:  Biomed Eng Online       Date:  2008-01-24       Impact factor: 2.819

7.  Identification of ultrasound imaging markers to quantify long bone regeneration in a segmental tibial defect sheep model in vivo.

Authors:  Songyuan Tang; Peer Shajudeen; Ennio Tasciotti; Raffaella Righetti
Journal:  Sci Rep       Date:  2020-08-12       Impact factor: 4.379

Review 8.  Breast Tumour Classification Using Ultrasound Elastography with Machine Learning: A Systematic Scoping Review.

Authors:  Ye-Jiao Mao; Hyo-Jung Lim; Ming Ni; Wai-Hin Yan; Duo Wai-Chi Wong; James Chung-Wai Cheung
Journal:  Cancers (Basel)       Date:  2022-01-12       Impact factor: 6.639

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.