Literature DB >> 1614312

Chemical shift imaging with phase-encoding RF pulses.

J Hennig1.   

Abstract

An inherent problem of conventional chemical shift imaging is signal contamination into adjacent voxels. This is especially severe in proton spectroscopy of the central nervous system, where the lipid signal from the skull is several orders of magnitude higher than the metabolite resonances from the brain. The reason for the contamination lies in the fact that the distribution of spins does not coincide with the discrete sampling matrix of the discrete Fourier transformation if a continuous phase-encoding scheme using magnetic field gradients is being used. This problem can be overcome if phase encoding is performed by appropriately phase-modulated RF pulses. It is demonstrated that contamination free spectra can be acquired from voxels immediately adjacent to the skull. Using small voxels of 1 x 1 x 2-ml regional variations of N-acetyl aspartate in the cerebellum of patients with oligopontine cerebellar atrophy could be observed.

Entities:  

Mesh:

Year:  1992        PMID: 1614312     DOI: 10.1002/mrm.1910250207

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  11 in total

Review 1.  A half-century of innovation in technology-preparing MRI for the 21st century.

Authors:  Peter Börnert; David G Norris
Journal:  Br J Radiol       Date:  2020-06-15       Impact factor: 3.039

2.  Assessment of arterial blood flow characteristics in normal and atherosclerotic vessels with the fast Fourier flow method.

Authors:  E Nesbitt; A Schmidt-Trucksäss; K A Il'yasov; H Weber; M Huonker; J Laubenberger; J Keul; J Hennig; M Langer
Journal:  MAGMA       Date:  2000-02       Impact factor: 2.310

Review 3.  In vivo 2D magnetic resonance spectroscopy of small animals.

Authors:  P Méric; G Autret; B T Doan; B Gillet; C Sébrié; J-C Beloeil
Journal:  MAGMA       Date:  2004-12-29       Impact factor: 2.310

Review 4.  Ultra-fast MRI of the human brain with simultaneous multi-slice imaging.

Authors:  David A Feinberg; Kawin Setsompop
Journal:  J Magn Reson       Date:  2013-02-13       Impact factor: 2.229

5.  Evaluation of slice accelerations using multiband echo planar imaging at 3 T.

Authors:  Junqian Xu; Steen Moeller; Edward J Auerbach; John Strupp; Stephen M Smith; David A Feinberg; Essa Yacoub; Kâmil Uğurbil
Journal:  Neuroimage       Date:  2013-07-27       Impact factor: 6.556

6.  Multiband accelerated spin-echo echo planar imaging with reduced peak RF power using time-shifted RF pulses.

Authors:  Edward J Auerbach; Junqian Xu; Essa Yacoub; Steen Moeller; Kâmil Uğurbil
Journal:  Magn Reson Med       Date:  2013-03-06       Impact factor: 4.668

Review 7.  Rapid brain MRI acquisition techniques at ultra-high fields.

Authors:  Kawin Setsompop; David A Feinberg; Jonathan R Polimeni
Journal:  NMR Biomed       Date:  2016-02-02       Impact factor: 4.044

8.  Silent BOLD imaging.

Authors:  T Loenneker; F Hennel; U Ludwig; J Hennig
Journal:  MAGMA       Date:  2001-10       Impact factor: 2.533

9.  High-resolution gradient-recalled echo imaging at 9.4T using 16-channel parallel transmit simultaneous multislice spokes excitations with slice-by-slice flip angle homogenization.

Authors:  Desmond H Y Tse; Christopher J Wiggins; Benedikt A Poser
Journal:  Magn Reson Med       Date:  2016-10-23       Impact factor: 4.668

Review 10.  Simultaneous multislice (SMS) imaging techniques.

Authors:  Markus Barth; Felix Breuer; Peter J Koopmans; David G Norris; Benedikt A Poser
Journal:  Magn Reson Med       Date:  2015-08-26       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.