Accuracy of electronic apex locators in comparison to actual length--an in vivo study.

C Haffner1, M Folwaczny, K Galler, R Hickel.   

Abstract

OBJECTIVES: The measurement precision of four electronic apex locators (Root ZX, Morita, Tokyo, Japan; Endy, Loser, Leverkusen, Germany; Justy II, Hager-Werken, Duisburg, Germany; Endox Lysis, Milan, Italy) was examined in the present in vivo study.
METHODS: The root canal length of 40 single-rooted and multi-rooted teeth was determined with the four devices prior to tooth extraction. To determine the actual root canal length, the apical third was longitudinally sectioned, the root canal instrument was positioned and the apex was examined using a microscope.
RESULTS: The average measurement deviation (+/-SD) in relation to the apical constriction was 0.3 mm (+/-0.6) for the Root ZX, 0.7 mm (+/-1.0) for the Endy, 0.2 mm (+/-0.7) for the Justy II and 1.3 mm (+/-1.7) for the Endox. The limit of +/-0.5 mm from the apical constriction was attained by the Root ZX in 78%, by the Endy in 67%, by the Justy II in 80% and by Endox in 31% of all measurements.
CONCLUSIONS: The latest generation of apex locaters provide the clinician with an accurate and useful adjunct for the determination of root canal length.

Mesh:

Year:  2005        PMID: 16139692     DOI: 10.1016/j.jdent.2004.11.017

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  8 in total

1.  Precision of multi-frequency electronic apex locators.

Authors:  Roy George
Journal:  Evid Based Dent       Date:  2016-09

2.  Comparative evaluation of accuracy of two electronic apex locators in the presence of various irrigants: An in vitro study.

Authors:  Saru Jain; Ravi Kapur
Journal:  Contemp Clin Dent       Date:  2012-09

3.  Accuracy of an Electronic Apex Locator for Working Length Determination in Primary Anterior Teeth.

Authors:  Zahra Bahrololoomi; Ali Asghar Soleymani; Jalil Modaresi; Mahsa Imanian; Malihe Lotfian
Journal:  J Dent (Tehran)       Date:  2015-04

4.  Calcium hydroxide dressing residues after different removal techniques affect the accuracy of Root-ZX apex locator.

Authors:  Emel Uzunoglu; Ayhan Eymirli; Mehmet Özgür Uyanik; Semra Çalt; Emre Nagas
Journal:  Restor Dent Endod       Date:  2014-11-05

5.  Working Length Determination Using Cone-Beam Computed Tomography, Periapical Radiography and Electronic Apex Locator in Teeth with Apical Periodontitis: A Clinical Study.

Authors:  André Luiz Gomide de Morais; Ana Helena Gonçalves de Alencar; Cyntia Rodrigues de Araújo Estrela; Daniel Almeida Decurcio; Carlos Estrela
Journal:  Iran Endod J       Date:  2016-05-01

6.  In vivo assessment of accuracy of Propex II, Root ZX II, and radiographic measurements for location of the major foramen.

Authors:  Fernanda Garcia Tampelini; Marcelo Santos Coelho; Marcos de Azevêdo Rios; Carlos Eduardo Fontana; Daniel Guimarães Pedro Rocha; Sergio Luiz Pinheiro; Carlos Eduardo da Silveira Bueno
Journal:  Restor Dent Endod       Date:  2017-05-16

7.  Comparison Between the Accuracy of NovApex Apex Locator and Radiographs in Determining Radiographic Apex.

Authors:  Shahriar Shahi; Saeed Rahimi; Amin Salem Milani; Mohammad Asghari Jafarabadi; Gholam Reza Djoorabbaf Naghsh
Journal:  Iran Endod J       Date:  2011-05-15

8.  An in vivo comparison of accuracy of two electronic apex locators in determining working length using stainless steel and nickel titanium files.

Authors:  Sanjeeb Chaudhary; Archana Gharti; Bhawana Adhikari
Journal:  Clin Cosmet Investig Dent       Date:  2018-05-22
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.