Literature DB >> 16138941

What plays a role in the choice of inhaler device for asthma therapy?

J Christian Virchow1.   

Abstract

Inhalation is the preferred route of delivery for anti-asthma drugs. However, in reality inhalers are often prescribed on an empirical basis rather than on evidence-based awareness. Asthma management guidelines also guide inhaler choice, but they offer non-specific advice regarding inhaler choice, are very long and complicated and not conducive to rapid assimilation by a busy GP. In addition, device selection criteria differ according to who you are asking (i.e. the inhalation technologist, the physician or the patient). The ideal inhaler should be small and have a guided sequence of inhalation, leading patients in a logical sequence of events through the inhalation manoeuvre. It should be breath-activated, releasing medication only when all prerequisites for successful inhalation are met. Most importantly, there should be flow-independent deposition of drug in the lungs and feedback on the successfully performed inhalation manoeuvre to reassure the patient that the drug has been successfully released from the inhaler. The ideal inhaler should also have a low intrinsic airflow resistance, making it suitable for use by patients who have a low inspiratory airflow (e.g. children and elderly patients). In order to check for compliance, the ideal inhaler should have an accurate dose counter which is linked to correct inhalation rather than simply to dose release, and patients should be able to use an identical inhaler device to deliver each of their different medications. Finally, from an environmental and cost-effectiveness point of view, the ideal inhaler should be refillable. Among the currently available dry powder inhalers the Novolizer device fulfils several characteristics of an ideal inhaler for the treatment of asthma and chronic obstructive pulmonary disease (COPD).

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16138941     DOI: 10.1185/030079905X61758

Source DB:  PubMed          Journal:  Curr Med Res Opin        ISSN: 0300-7995            Impact factor:   2.580


  6 in total

1.  Efficacy and safety of the single-capsule combination of fluticasone/formoterol in patients with persistent asthma: a non-inferiority trial.

Authors:  Marti Antilla; Fábio Castro; Álvaro Cruz; Adalberto Rubin; Nelson Rosário; Rafael Stelmach
Journal:  J Bras Pneumol       Date:  2014 Nov-Dec       Impact factor: 2.624

2.  Acceptability and preference of three inhalation devices assessed by the Handling Questionnaire in asthma and COPD patients.

Authors:  Roberto W Dal Negro; Massimiliano Povero
Journal:  Multidiscip Respir Med       Date:  2016-02-10

3.  Dry-powder inhalers in patients with persistent airflow limitation: usability and preference.

Authors:  Roberto W Dal Negro; Massimiliano Povero
Journal:  Multidiscip Respir Med       Date:  2016-09-05

4.  Inspiratory flow profile and usability of the NEXThaler, a multidose dry powder inhaler, in asthma and COPD.

Authors:  Alfredo Chetta; Arzu Yorgancioglu; Mario Scuri; Sara Barile; Daniele Guastalla; P N Richard Dekhuijzen
Journal:  BMC Pulm Med       Date:  2021-02-25       Impact factor: 3.317

5.  The challenge of delivering therapeutic aerosols to asthma patients.

Authors:  Federico Lavorini
Journal:  ISRN Allergy       Date:  2013-08-05

Review 6.  Patients' perspectives and preferences in the choice of inhalers: the case for Respimat(®) or HandiHaler(®).

Authors:  Pieter Nicolaas Richard Dekhuijzen; Federico Lavorini; Omar S Usmani
Journal:  Patient Prefer Adherence       Date:  2016-08-18       Impact factor: 2.711

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.