Fluorinated diamond-like carbon as antithrombogenic coating for blood-contacting devices.

Terumitsu Hasebe1, Atsushi Shimada, Tetsuya Suzuki, Yoshiaki Matsuoka, Toshiya Saito, Satoshi Yohena, Aki Kamijo, Nobuyuki Shiraga, Mutsumi Higuchi, Kanako Kimura, Hirokuni Yoshimura, Sachio Kuribayashi.   

Abstract

Diamond-like carbon (DLC) is being considered for widespread clinical use as a surface coating for cardiovascular devices. We synthesized fluorinated DLC (F-DLC) coatings in order to create a more hydrophobic surface with improved antithrombogenicity and flexibility when compared with conventional DLC coatings by combining the inertness of DLC films with the advantage of fluorination. The purpose of this study was to evaluate the in vitro hemocompatibility and in vivo biocompatibility of the F-DLC coating for medical devices. The in vitro whole blood model confirmed that platelet loss was lower in the F-DLC group than in the noncoated group (SUS316L), which suggests the adhesion of a smaller number of platelets to F-DLC-coated materials. Furthermore, the biomarkers of mechanically induced platelet activation (beta-thromboglobulin) and activated coagulation (thrombin-antithrombin-three complex) were markedly reduced in the F-DLC-coated group. In vivo rat implant model studies revealed no excessive local and systemic inflammatory responses in the F-DLC group. The thickness of the fibrous tissue capsule surrounding the F-DLC-coated disk was almost equal to that of the noncoated SUS316L disk, which has the favorable biocompatibility for metallic implant materials. F-DLC coating thus appears to be a promising candidate for use as a coating material in blood-contacting devices. (c) 2005 Wiley Periodicals, Inc

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16138324     DOI: 10.1002/jbm.a.30512

Source DB:  PubMed          Journal:  J Biomed Mater Res A        ISSN: 1549-3296            Impact factor:   4.396


  12 in total

1.  Corrosion resistance improvement for 316L stainless steel coronary artery stents by trimethylsilane plasma nanocoatings.

Authors:  John Eric Jones; Meng Chen; Qingsong Yu
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2014-02-06       Impact factor: 3.368

2.  Adhesion and differentiation of Saos-2 osteoblast-like cells on chromium-doped diamond-like carbon coatings.

Authors:  Elena Filova; Marta Vandrovcova; Miroslav Jelinek; Josef Zemek; Jana Houdkova; Tomas Kocourek; Lubica Stankova; Lucie Bacakova
Journal:  J Mater Sci Mater Med       Date:  2016-12-20       Impact factor: 3.896

Review 3.  Microfabrication and nanotechnology in stent design.

Authors:  Adam W Martinez; Elliot L Chaikof
Journal:  Wiley Interdiscip Rev Nanomed Nanobiotechnol       Date:  2011-01-31

4.  Surface-Modifying Effect of Zwitterionic Polyurethane Oligomers Complexed with Metal Ions on Blood Compatibility.

Authors:  Dong-Heon Ga; Chung-Man Lim; Yoonsun Jang; Tae Il Son; Dong Keun Han; Yoon Ki Joung
Journal:  Tissue Eng Regen Med       Date:  2021-10-22       Impact factor: 4.451

5.  Comparison of neointimal hyperplasia and peri-stent vascular remodeling after implantation of everolimus-eluting versus sirolimus-eluting stents: intravascular ultrasound results from the EXCELLENT study.

Authors:  Young-Guk Ko; Dong-Ho Shin; Jung-Sun Kim; Byeong-Keuk Kim; Donghoon Choi; Myeong-Ki Hong; Hyeon-Cheol Gwon; Taehoon Ahn; In-Ho Chae; Jung-Han Yoon; Hyo-Soo Kim; Yangsoo Jang
Journal:  Int J Cardiovasc Imaging       Date:  2013-03-03       Impact factor: 2.357

6.  Active wrinkles to drive self-cleaning: A strategy for anti-thrombotic surfaces for vascular grafts.

Authors:  Luka Pocivavsek; Sang-Ho Ye; Joseph Pugar; Edith Tzeng; Enrique Cerda; Sachin Velankar; William R Wagner
Journal:  Biomaterials       Date:  2018-11-05       Impact factor: 12.479

7.  Improvement in endothelial cell adhesion and retention under physiological shear stress using a laminin-apatite composite layer on titanium.

Authors:  Fupo He; Xiupeng Wang; Osamu Maruyama; Ryo Kosaka; Yu Sogo; Atsuo Ito; Jiandong Ye
Journal:  J R Soc Interface       Date:  2013-02-13       Impact factor: 4.118

8.  Multi-layer haemocompatible diamond-like carbon coatings obtained by combined radio frequency plasma enhanced chemical vapor deposition and magnetron sputtering.

Authors:  A C Popa; G E Stan; M A Husanu; I Pasuk; I D Popescu; A C Popescu; I N Mihailescu
Journal:  J Mater Sci Mater Med       Date:  2013-08-13       Impact factor: 3.896

Review 9.  Reappraisal of Percutaneous Transluminal Laser Angioplasty.

Authors:  Shoichi D Takekawa
Journal:  Laser Ther       Date:  2017-12-31

10.  Hemocompatibility of Inorganic Physical Vapor Deposition (PVD) Coatings on Thermoplastic Polyurethane Polymers.

Authors:  Juergen M Lackner; Wolfgang Waldhauser; Paul Hartmann; Franz Bruckert; Marianne Weidenhaupt; Roman Major; Marek Sanak; Martin Wiesinger; Daniel Heim
Journal:  J Funct Biomater       Date:  2012-04-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.