Literature DB >> 16137089

Direct implant loading in the edentulous maxilla using a bone density-adapted surgical protocol and primary implant stability criteria for inclusion.

Pär-Olov Ostman1, Mats Hellman, Lars Sennerby.   

Abstract

BACKGROUND: Long healing periods and submerged implant placement are commonly used in the maxilla. This extends the time of oral handicap and makes the use of immediate loading protocols an attractive option. The current clinical literature on direct loading of dental implants in the maxilla is limited.
PURPOSE: The purpose of this prospective clinical study was to evaluate the clinical outcome and stability of directly loaded Brånemark System or Replace Select Tapered implants (Nobel Biocare AB, Göteborg, Sweden) after using a modified surgical protocol and inclusion by primary implant stability. In addition, a reference group treated according to a two-stage protocol was used for comparison.
MATERIALS AND METHODS: Twenty patients planned for prosthetic rehabilitation with implant-supported bridges in the edentulous maxilla participated in the study group. The final decision on immediate loading was made after implant placement using insertion torque and resonance frequency analysis (RFA) as acceptance criteria. All patients were included, and 123 oxidized implants (TiUnite, Nobel Biocare AB) were placed using a surgical protocol for enhanced primary stability. A screw-retained temporary bridge was delivered within 12 hours and a final bridge within 3 months of implant placement. The patients were monitored through clinical and radiographic follow-up examinations from implant placement to at least 12 months. Marginal bone level was measured at bridge delivery and after 12 months of loading. Additional RFA measurements were made after 6 months of loading. A reference group comprising 20 patients with 120 implants treated according to a two-stage protocol was used for comparison.
RESULTS: One (0.8%) of the 123 implants in the study group failed, and no implant was lost in the reference group. The cumulative survival rates after 12 months of loading were thus 99.2% and 100% for immediate and delayed loading protocols, respectively. The marginal bone resorption was 0.78 (SD 0.9) in the study group and 0.91 (SD 1.04) in the reference group. RFA showed a mean value of 62.9 (SD 4.9) implant stability quotient (ISQ) at placement and 64.5 (SD 4.8) ISQ after 6 months for immediately loaded implants (not significant). The corresponding figures for the reference groups were 61.3 (SD 8.8) ISQ and 62.6 (SD 7.0) ISQ (not significant). There were no statistically significant differences between the groups at any time point.
CONCLUSION: The use of six to seven implants for immediate loading of a fixed provisional bridge is a viable option for implant treatment of the edentulous maxilla, at least when good primary implant stability can be ensured.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16137089     DOI: 10.1111/j.1708-8208.2005.tb00076.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  21 in total

1.  Clinical study on the primary stability of two dental implant systems with resonance frequency analysis.

Authors:  Annette Rabel; Steffen Gerhard Köhler; Andrea Maria Schmidt-Westhausen
Journal:  Clin Oral Investig       Date:  2007-03-31       Impact factor: 3.573

2.  The influence of thread geometry on implant osseointegration under immediate loading: a literature review.

Authors:  Hyo-Sook Ryu; Cheol Namgung; Jong-Ho Lee; Young-Jun Lim
Journal:  J Adv Prosthodont       Date:  2014-12-17       Impact factor: 1.904

3.  Computer-guided technique evaluation of the bony palate for planning individual implant placement.

Authors:  Pinar Cagimni; Figen Govsa; Mehmet Asim Ozer; Zuhal Kazak
Journal:  Surg Radiol Anat       Date:  2016-10-25       Impact factor: 1.246

4.  Surface properties and early murine pre-osteoblastic cell responses of phosphoric acid modified titanium surface.

Authors:  Thanaphum Osathanon; Chenphop Sawangmake; Nanticha Ruangchainicom; Pavitra Wutikornwipak; Panisa Kantukiti; Nunthawan Nowwarote; Prasit Pavasant
Journal:  J Oral Biol Craniofac Res       Date:  2015-12-24

5.  Evaluation of the correlation between insertion torque and primary stability of dental implants using a block bone test.

Authors:  Dorjpalam Bayarchimeg; Hee Namgoong; Byung Kook Kim; Myung Duk Kim; Sungtae Kim; Tae-Il Kim; Yang Jo Seol; Yong Moo Lee; Young Ku; In-Chul Rhyu; Eun Hee Lee; Ki-Tae Koo
Journal:  J Periodontal Implant Sci       Date:  2013-02-28       Impact factor: 2.614

Review 6.  Comparing success of immediate versus delay loading of implants in fresh sockets: a systematic review and meta-analysis.

Authors:  Ebrahim Eini; Hojatollah Yousefimanesh; Alireza Hashemi Ashtiani; Amal Saki-Malehi; Amin Olapour; Fakher Rahim
Journal:  Oral Maxillofac Surg       Date:  2021-07-12

7.  2D FEA of evaluation of micromovements and stresses at bone-implant interface in immediately loaded tapered implants in the posterior maxilla.

Authors:  Shrikar R Desai; Rika Singh; I Karthikeyan
Journal:  J Indian Soc Periodontol       Date:  2013-09

8.  Clinical and Radiographic Evaluation of Brånemark Implants with an Anodized Surface following Seven-to-Eight Years of Functional Loading.

Authors:  David Gelb; Bradley McAllister; Pirkka Nummikoski; Massimo Del Fabbro
Journal:  Int J Dent       Date:  2013-03-07

9.  Early loading of hydrophilic titanium implants inserted in low-mineralized (D3 and D4) bone: one year results of a prospective clinical trial.

Authors:  Uwe Held; Dennis Rohner; Daniel Rothamel
Journal:  Head Face Med       Date:  2013-12-09       Impact factor: 2.151

Review 10.  Immediate loading with fixed full-arch prostheses in the maxilla: review of the literature.

Authors:  David Peñarrocha-Oltra; Ugo Covani; Miguel Peñarrocha-Diago; Maria Peñarrocha-Diago
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2014-09-01
View more