Literature DB >> 16133031

A survey of satisfaction in anophthalmic patients wearing ocular prosthesis.

Jong-Suk Song1, Jaeryung Oh, Se Hyun Baek.   

Abstract

PURPOSE: The purpose of this study was to evaluate patient satisfaction with ocular prosthesis after evisceration or enucleation and to determine which variables were correlated to their satisfaction in order to find out how to increase patient satisfaction.
METHODS: A satisfaction questionnaire was given to consecutive anophthalmic patients who visited Korea University Hospital from March 2002 through August 2002. Many kinds of variables such as age, gender, type of implant, pegging, and postoperative ocular symptoms that might influence patient satisfaction were evaluated by correlation analysis and multivariate analysis to find the determinants of patient satisfaction.
RESULTS: The overall rate of satisfaction with ocular prosthesis was 71.8%. The variables significantly correlated to patient satisfaction were economic status, other people's response, and insertion of motility coupling post or motility peg.
CONCLUSION: Patient satisfaction with ocular prosthesis was relatively high. Successful peg insertion to improve the prosthesis movement may be one way for surgeons to increase patient satisfaction.

Entities:  

Mesh:

Year:  2005        PMID: 16133031     DOI: 10.1007/s00417-005-0037-0

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  25 in total

Review 1.  Enucleation.

Authors:  D M Moshfeghi; A A Moshfeghi; P T Finger
Journal:  Surv Ophthalmol       Date:  2000 Jan-Feb       Impact factor: 6.048

2.  Satisfaction with medical care: its measurement and relation to utilization.

Authors:  K J Roghmann; A Hengst; T R Zastowny
Journal:  Med Care       Date:  1979-05       Impact factor: 2.983

3.  Double sphere orbital implantation in enucleation and evisceration.

Authors:  A Hornblass; B J Herschorn
Journal:  Ophthalmic Plast Reconstr Surg       Date:  1985       Impact factor: 1.746

4.  Causes of enucleation as seen in Jerusalem.

Authors:  K L Batten
Journal:  Br J Ophthalmol       Date:  1971-03       Impact factor: 4.638

5.  Quality of life after first- and second-eye cataract surgery: five-year data collected by the Swedish National Cataract Register.

Authors:  M Lundström; U Stenevi; W Thorburn
Journal:  J Cataract Refract Surg       Date:  2001-10       Impact factor: 3.351

6.  High-density porous polyethylene (Medpor) as a successful anophthalmic socket implant.

Authors:  J W Karesh; S C Dresner
Journal:  Ophthalmology       Date:  1994-10       Impact factor: 12.079

Review 7.  Evisceration with hydroxyapatite implant. Surgical technique and review of 31 case reports.

Authors:  D A Kostick; J V Linberg
Journal:  Ophthalmology       Date:  1995-10       Impact factor: 12.079

8.  Prosthetic motility in pegged versus unpegged integrated porous orbital implants.

Authors:  Paulo Guillinta; Sunil N Vasani; David B Granet; Don O Kikkawa
Journal:  Ophthalmic Plast Reconstr Surg       Date:  2003-03       Impact factor: 1.746

9.  Transconjunctival laser blepharoplasty of lower eyelids: Asian experience with 1,340 cases.

Authors:  Sung-Wan Kim; Whan-Soo Kim; Moon-Kyun Cho; Kyu-Uang Whang
Journal:  Dermatol Surg       Date:  2003-01       Impact factor: 3.398

10.  Baseball orbital implants: a review of 39 patients.

Authors:  A G Tyers; J R Collin
Journal:  Br J Ophthalmol       Date:  1985-06       Impact factor: 4.638

View more
  13 in total

Review 1.  [Ocular prosthetics. Fitting, daily use and complications].

Authors:  K R Koch; W Trester; N Müller-Uri; M Trester; C Cursiefen; L M Heindl
Journal:  Ophthalmologe       Date:  2016-02       Impact factor: 1.059

2.  Concerns of anophthalmic patients-a comparison between cryolite glass and polymethyl methacrylate prosthetic eye wearers.

Authors:  Alexander C Rokohl; Konrad R Koch; Werner Adler; Marc Trester; Wolfgang Trester; Nicola S Pine; Keith R Pine; Ludwig M Heindl
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2018-03-03       Impact factor: 3.117

3.  Short-term effects of topical cyclosporine A 0.05% (Restasis) in long-standing prosthetic eye wearers: a pilot study.

Authors:  J W Han; J S Yoon; S Y Jang
Journal:  Eye (Lond)       Date:  2014-08-01       Impact factor: 3.775

4.  The UK National Artificial Eye Questionnaire Study: predictors of artificial eye wearers' experience Part 2 - visual function and quality of life.

Authors:  Yinon Shapira; Emma Worrell; Andre S Litwin; Raman Malhotra
Journal:  Eye (Lond)       Date:  2021-03-01       Impact factor: 3.775

5.  Patient experiences in retinal trials: a cross-sectional study.

Authors:  Cheryl Pui-Yan Au; Nicole Fardell; Maria Williams; Samantha Fraser-Bell; Anna Campain; Mark Gillies
Journal:  BMC Ophthalmol       Date:  2015-07-23       Impact factor: 2.209

6.  Safety and Biocompatibility of a New High-Density Polyethylene-Based Spherical Integrated Porous Orbital Implant: An Experimental Study in Rabbits.

Authors:  Ivan Fernandez-Bueno; Salvatore Di Lauro; Ivan Alvarez; Jose Carlos Lopez; Maria Teresa Garcia-Gutierrez; Itziar Fernandez; Eva Larra; Jose Carlos Pastor
Journal:  J Ophthalmol       Date:  2015-11-24       Impact factor: 1.909

7.  Evaluation of the color stability of two techniques for reproducing artificial irides after microwave polymerization.

Authors:  Marcelo Coelho Goiato; Daniela Micheline dos Santos; Amália Moreno; Humberto Gennari-Filho; Eduardo Piza Pellizzer
Journal:  J Appl Oral Sci       Date:  2011 May-Jun       Impact factor: 2.698

8.  Custom ocular prosthesis in rehabilitation of a child operated for retinoblastoma.

Authors:  Vinit Shah; Lakshya Yadav; Mayank Singh; Smriti Kharbanda
Journal:  Natl J Maxillofac Surg       Date:  2015 Jul-Dec

9.  Prevalence of ocular defects among patients visiting in an institutionalized hospital setting: A cross-sectional study.

Authors:  Neerja Raj; Mayank Singh; Vineet Raj; Mohd Anwar; Lakshya Kumar
Journal:  Natl J Maxillofac Surg       Date:  2016 Jan-Jun

10.  Psychological symptoms in anophthalmic patients wearing ocular prosthesis and related factors.

Authors:  Kai Jie Wang; Sha Sha Li; Hai Yan Wang
Journal:  Medicine (Baltimore)       Date:  2020-07-17       Impact factor: 1.817