Literature DB >> 16131077

Characterization and performance of MALDI on a triple quadrupole mass spectrometer for analysis and quantification of small molecules.

Jason Gobey1, Mark Cole, John Janiszewski, Thomas Covey, Tung Chau, Peter Kovarik, Jay Corr.   

Abstract

The usefulness of MALDI for small-molecule work has been limited by matrix chemical interference in the mass range of interest, tedious sample preparation, and various crystallization and sample deposition issues. We report instrument characterization and small-molecule quantification performance data from a high repetition rate laser MALDI ion source coupled to a triple quadrupole mass spectrometer. The high repetition rate laser improves sensitivity and precision and allows a proportional increase in sample throughput. Tandem mass spectrometry is used to discriminate the signal from the high chemical background caused by the MALDI matrix. Successful quantification requires use of an internal standard and a means of sample cleanup for typical in vitro sample compositions. This instrument combination and analysis technique is relatively insensitive to sample crystal quality and spot homogeneity. Quantitative performance results are characterized for 53 small-molecule pharmaceutical compounds and compared to those obtained by ESI-MS/MS. Further comparison between MALDI and ESI is examined, and the potential for high-throughput MALDI-MS/MS quantification is demonstrated.

Mesh:

Substances:

Year:  2005        PMID: 16131077     DOI: 10.1021/ac0506130

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  17 in total

1.  Design considerations for high speed quantitative mass spectrometry with MALDI ionization.

Authors:  Jay J Corr; Peter Kovarik; Bradley B Schneider; Jan Hendrikse; Alexander Loboda; Thomas R Covey
Journal:  J Am Soc Mass Spectrom       Date:  2006-06-05       Impact factor: 3.109

2.  A useful binary matrix for visible-MALDI of low molecular weight analytes.

Authors:  Chunyan Yang; Xiaokun Hu; Alexandre V Loboda; Robert H Lipson
Journal:  J Am Soc Mass Spectrom       Date:  2009-10-29       Impact factor: 3.109

3.  A Novel PET Probe "[18F]DiFA" Accumulates in Hypoxic Region via Glutathione Conjugation Following Reductive Metabolism.

Authors:  Yoichi Shimizu; Songji Zhao; Hironobu Yasui; Ken-Ichi Nishijima; Hiroki Matsumoto; Tohru Shiga; Nagara Tamaki; Mikako Ogawa; Yuji Kuge
Journal:  Mol Imaging Biol       Date:  2019-02       Impact factor: 3.488

4.  Quantification of small molecule drugs in biological tissue sections by imaging mass spectrometry using surrogate tissue-based calibration standards.

Authors:  Nozomi Takai; Yukari Tanaka; Hideo Saji
Journal:  Mass Spectrom (Tokyo)       Date:  2014-02-01

5.  Parts per Million Powder X-ray Diffraction.

Authors:  Justin A Newman; Paul D Schmitt; Scott J Toth; Fengyuan Deng; Shijie Zhang; Garth J Simpson
Journal:  Anal Chem       Date:  2015-10-22       Impact factor: 6.986

6.  A binary matrix for the rapid detection and characterization of small-molecule cardiovascular drugs by MALDI-MS and MS/MS.

Authors:  Jinlan Dong; Wenjing Ning; Daniel J Mans; Jamie D Mans
Journal:  Anal Methods       Date:  2018-02-01       Impact factor: 2.896

7.  MALDI TOF/TOF tandem mass spectrometry as a new tool for amino acid analysis.

Authors:  Natalia V Gogichaeva; Todd Williams; Michail A Alterman
Journal:  J Am Soc Mass Spectrom       Date:  2006-10-30       Impact factor: 3.109

8.  Ultra-fast analysis of plasma and intracellular levels of HIV protease inhibitors in children: a clinical application of MALDI mass spectrometry.

Authors:  Jeroen J A van Kampen; Mariska L Reedijk; Peter C Burgers; Lennard J M Dekker; Nico G Hartwig; Ineke E van der Ende; Ronald de Groot; Albert D M E Osterhaus; David M Burger; Theo M Luider; Rob A Gruters
Journal:  PLoS One       Date:  2010-07-01       Impact factor: 3.240

9.  Study of Isobaric Interference in Quantification of Citrulline by Parallel Fragmentation Monitoring.

Authors:  Eddy Wing Yin Ng; Hugh Simon Lam; Pak Cheung Ng; Terence Chuen Wai Poon
Journal:  Mass Spectrom (Tokyo)       Date:  2014-05-01

Review 10.  Advancing the sensitivity of selected reaction monitoring-based targeted quantitative proteomics.

Authors:  Tujin Shi; Dian Su; Tao Liu; Keqi Tang; David G Camp; Wei-Jun Qian; Richard D Smith
Journal:  Proteomics       Date:  2012-04       Impact factor: 3.984

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.