Literature DB >> 16130869

Microscopic evaluation of dentin interface obtained with 10 contemporary self-etching systems: correlation with their pH.

Geneviéve Grégoire1, Arlette Millas.   

Abstract

This study investigated micromorphological differences in the hybridized complex formed using 10 commercially available self-etch bonding systems. In addition, the influence of the pH of the primer of these adhesives was evaluated. The self-etching systems tested were AdheSE, Adper Prompt L-Pop, Clearfil SE Bond, Etch&Prime 3.0 (Degussa, Germany), Prime & Bond NT Non Rinse Conditioner (Dentsply, Konstanz, Germany), One-Up Bond F, OptiBond Solo Plus Self Etch, Prompt L-Pop and Xeno III. One hundred non-carious human third molars were used. The teeth were divided into two groups of 50 and prepared for evaluation by optical microscopy or scanning electron microscopy. The specimens in each group were further divided into 10 subgroups of five specimens each to evaluate the 10 bonding systems. The pH of the primers of the bonding systems was measured. The results demonstrated morphological differences at the interface, depending on adhesive composition. The differences mainly concerned thickness of the hybrid layer, the absence or presence of microscopic voids at the adhesive-composite interface and whether the dentinal tubuli were completely sealed. The pH was not the determining factor conditioning the action of the self-etching adhesives.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16130869

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  5 in total

1.  Morphology of the smear layer after the application of simplified self-etch adhesives on enamel and dentin surfaces created with different preparation methods.

Authors:  Tissiana Bortolotto; Marco Ferrari; Alexandre Susin; Ivo Krejci
Journal:  Clin Oral Investig       Date:  2009-01-09       Impact factor: 3.573

2.  Evaluation of the furcation area permeability of deciduous molars treated by neodymium:yttrium-aluminum-garnet laser or adhesive.

Authors:  Camila A B Guglielmi; Karen Müller Ramalho; Tais Scaramucci; Sandra Regina Echeverria P da Silva; José Carlos P Imparato; Sérgio Luiz Pinheiro
Journal:  Lasers Med Sci       Date:  2009-09-08       Impact factor: 3.161

3.  Randomized Clinical Trial of Composite Restorations in Primary Teeth: Effect of Adhesive System after Three Years.

Authors:  Secil Bektaş Donmez; Melek D Turgut; Serdar Uysal; Pinar Ozdemir; Meryem Tekcicek; Brigitte Zimmerli; Adrian Lussi
Journal:  Biomed Res Int       Date:  2016-10-19       Impact factor: 3.411

4.  Effect of Dentin Wetness on the Bond Strength of Universal Adhesives.

Authors:  An-Na Choi; Ji-Hye Lee; Sung-Ae Son; Kyoung-Hwa Jung; Yong Hoon Kwon; Jeong-Kil Park
Journal:  Materials (Basel)       Date:  2017-10-25       Impact factor: 3.623

5.  Comparative scanning electron microscopic study of the effect of different dental conditioners on dentin micromorphology.

Authors:  Alexandre Henrique Susin; Luana Severo Alves; Gliciana Piovesan de Melo; Tathiane Larissa Lenzi
Journal:  J Appl Oral Sci       Date:  2008 Mar-Apr       Impact factor: 2.698

  5 in total