Three groups of structurally diverse chiral compounds were used to study the interaction mechanism responsible for stereoselective recognition with teicoplanin as chiral selector in capillary liquid chromatography. Teicoplanin-based chiral stationary phase (CSP) was used. The effect of the variation of mobile phase composition on retention and enantioselective separation was studied. The mobile phase composition suitable for enantioresolution of the various chiral compounds differed according to the interaction forces needed for chiral recognition. Mobile phases with high buffer portion (70-90 vol.%) were preferred for separation of enantiomers of profen non-steroidal anti-inflammatory drugs and chlorophenoxypropionic acid herbicides that require hydrophobic interactions, inclusion and pi-pi interactions for stereoselective recognition with teicoplanin. Higher concentration triethylamine in the buffer (0.5-1.0%) increased resolution of these acids. On the other hand, H-bonding and electrostatic interactions are important in stereoselective interaction mechanism of beta-adrenergic antagonists with teicoplanin. These interaction types predominate in the reversed phase separation mode with high organic modifier content (95% methanol) and in polar organic mobile phases. For this reason beta-adrenergic antagonists were best enantioresolved in the polar organic mode. The mobile phase composed of methanol/acetic acid/triethylamine, 100/0.01/0.01 (v/v/v), provided enantioresolution values of all the studied beta-adrenergic antagonists in the range 1.1-1.9. Addition of teicoplanin to the mobile phase, which was suitable for enantioseparation of certain compounds on the CSP, was also investigated. This system was used to dispose of nonstereoselective interactions of analytes with silica gel support that often participate in the interaction with CSPs. Very low concentration of teicoplanin in the mobile phase (0.1 mM) resulted in enantioselective separation of 2,2- and 2,4-chlorophenoxypropionic acids.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16130735     DOI: 10.1016/j.chroma.2005.02.027

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

1.  Enantioseparations of Chiral Ruthenium(II) Polypyridyl Complexes Using HPLC with Macrocyclic Glycopeptide Chiral Stationary Phases (CSPs).

Authors:  Ping Sun; Arthi Krishnan; Abhishek Yadav; Frederick M MacDonnell; Daniel W Armstrong
Journal:  J Mol Struct       Date:  2008-11-12       Impact factor: 3.196

2.  Stereoselective Pharmacokinetics of Ketoprofen After Oral Administration of Modified-Release Formulations in Caucasian Healthy Subjects.

Authors:  Marianela Lorier; Laura Magallanes; Manuel Ibarra; Natalia Guevara; Marta Vázquez; Pietro Fagiolino
Journal:  Eur J Drug Metab Pharmacokinet       Date:  2016-12       Impact factor: 2.441

3.  Development of square-wave adsorptive stripping voltammetric method for determination of acebutolol in pharmaceutical formulations and biological fluids.

Authors:  Ali F Al-Ghamdi; Mohamed M Hefnawy; Abdulrahman A Al-Majed; Fatallah F Belal
Journal:  Chem Cent J       Date:  2012-02-21       Impact factor: 4.215

4.  Decorated single-enantiomer phosphoramide-based silica/magnetic nanocomposites for direct enantioseparation.

Authors:  Fatemeh Karimi Ahmadabad; Mehrdad Pourayoubi; Hadi Bakhshi
Journal:  RSC Adv       Date:  2019-08-29       Impact factor: 4.036

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.