Literature DB >> 16125812

Real-time transthoracic three-dimensional echocardiography provides additional information of left-sided AV valve morphology after AVSD repair.

A E van den Bosch1, V F van Dijk, J S McGhie, A J J C Bogers, J W Roos-Hesselink, M L Simoons, F J Meijboom.   

Abstract

AIMS: The purpose of this study was to assess the feasibility of real-time 3D echocardiography (RT-3DE) data acquisition in adult patients after atrioventricular septal defect (AVSD) repair and to evaluate whether RT-3DE has additional value over 2D echocardiography, regarding morphology and function of the left-sided AV valve (LAVV).
METHODS: Twenty consecutive patients with surgically corrected partial or complete AVSD were enrolled in this study. The 3DE data sets were acquired with the Hewlett-Packard Sonos 7500 echo system (Philips Medical Systems, Andover, MA, USA). Images were reviewed off-line with assistance of TomTec Echoview 5.2 software (TomTec Inc., Munich, Germany) by experienced observers. En face reconstructions, from, respectively, the ventricular and atrial view, were made to evaluate the LAVV morphology and motion.
RESULTS: 3DE reconstruction of the LAVV was feasible in 17 of 20 patients (85%). Mean time of 3DE acquisition was 9+/-6 min. The quality of the 3DE images was optimal in 35%, good in 30%, sufficient in 20% and insufficient in 15%. Identification of the LAVV structures was importantly better facilitated from a ventricular view. Accurate identification of LAVV morphology was possible in all 17 patients (85%). Relationship of the LAVV and the abnormal position of the LVOT was easier to evaluate from the 3DE reconstructions than from 2D echo.
CONCLUSION: This study demonstrate that RT-3DE is feasible in daily practice and provides new insight into the dynamic morphology of the left-sided AV valve and LVOT anatomy after AVSD repair.

Entities:  

Mesh:

Year:  2005        PMID: 16125812     DOI: 10.1016/j.ijcard.2005.02.014

Source DB:  PubMed          Journal:  Int J Cardiol        ISSN: 0167-5273            Impact factor:   4.164


  4 in total

1.  Multi-factorial analytical study on real-time three-dimensional echocardiographic cardiac image display quality.

Authors:  Guo-Zhen Chen; Kun Sun
Journal:  Int J Cardiovasc Imaging       Date:  2010-09-05       Impact factor: 2.357

2.  Usefulness of the multiplanar reformatting mode of three-dimensional echocardiography in evaluating valvular and structural heart disease: An experience from Saudi Arabia.

Authors:  Saad Q Khoshhal
Journal:  J Saudi Heart Assoc       Date:  2013-11-13

Review 3.  Feasibility and effectiveness of three-dimensional echocardiography in diagnosing congenital heart diseases.

Authors:  Saad Khoshhal
Journal:  Pediatr Cardiol       Date:  2013-05-16       Impact factor: 1.655

Review 4.  What is new in pediatric cardiac imaging?

Authors:  Luc Mertens; Javier Ganame; Bénédicte Eyskens
Journal:  Eur J Pediatr       Date:  2007-07-10       Impact factor: 3.183

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.