Literature DB >> 16119238

Fast tracking of cardiac motion using 3D-HARP.

Li Pan1, Jerry L Prince, João A C Lima, Nael F Osman.   

Abstract

Magnetic resonance (MR) tagging is capable of accurate, noninvasive quantification of regional myocardial function. Routine clinical use, however, is hindered by cumbersome and time-consuming postprocessing procedures. We propose a fast, semiautomatic method for tracking three-dimensional (3-D) cardiac motion from a temporal sequence of short- and long-axis tagged MR images. The new method, called 3-D-HARmonic Phase (3D-HARP), extends the HARP approach, previously described for two-dimensional (2-D) tag analysis, to 3-D. A 3-D material mesh model is built to represent a collection of material points inside the left ventricle (LV) wall at a reference time. Harmonic phase, a material property that is time-invariant, is used to track the motion of the mesh through a cardiac cycle. Various motion-related functional properties of the myocardium, such as circumferential strain and left ventricular twist, are computed from the tracked mesh. The correlation analysis of 3D-HARP and FINDTAGS + Tag Strain(E) Analysis (TEA), which are well-established tag analysis techniques, shows that the regression coefficients of circumferential strain (E(CC)) and twist angle are r2 = 0.8605 and r2 = 0.8645, respectively. The total time required for tracking 3-D cardiac motion is approximately 10 min in a 9 timeframe tagged MRI dataset and has the potential to be much faster.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16119238     DOI: 10.1109/TBME.2005.851490

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  29 in total

1.  Incompressible deformation estimation algorithm (IDEA) from tagged MR images.

Authors:  Xiaofeng Liu; Khaled Z Abd-Elmoniem; Maureen Stone; Emi Z Murano; Jiachen Zhuo; Rao P Gullapalli; Jerry L Prince
Journal:  IEEE Trans Med Imaging       Date:  2011-09-19       Impact factor: 10.048

2.  Accurate two-dimensional cardiac strain calculation using adaptive windowed Fourier transform and Gabor wavelet transform.

Authors:  Y B Fu; C K Chui; C L Teo
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-04-24       Impact factor: 2.924

3.  Left ventricular modelling: a quantitative functional assessment tool based on cardiac magnetic resonance imaging.

Authors:  C A Conti; E Votta; C Corsi; D De Marchi; G Tarroni; M Stevanella; M Lombardi; O Parodi; E G Caiani; A Redaelli
Journal:  Interface Focus       Date:  2011-03-23       Impact factor: 3.906

4.  [Myocardial MR tagging: analysis of regional and global myocardial function].

Authors:  U Kramer; A Hennemuth; M Fenchel
Journal:  Radiologe       Date:  2010-06       Impact factor: 0.635

5.  Oblique 3D MRI tags for the estimation of true 3D cardiac motion parameters.

Authors:  Yu Shimizu; Akira Amano; Tetsuya Matsuda
Journal:  Int J Cardiovasc Imaging       Date:  2010-06-08       Impact factor: 2.357

6.  Meshless deformable models for 3D cardiac motion and strain analysis from tagged MRI.

Authors:  Xiaoxu Wang; Ting Chen; Shaoting Zhang; Joël Schaerer; Zhen Qian; Suejung Huh; Dimitris Metaxas; Leon Axel
Journal:  Magn Reson Imaging       Date:  2014-08-23       Impact factor: 2.546

7.  Direct three-dimensional myocardial strain tensor quantification and tracking using zHARP.

Authors:  Khaled Z Abd-Elmoniem; Matthias Stuber; Jerry L Prince
Journal:  Med Image Anal       Date:  2008-04-15       Impact factor: 8.545

Review 8.  Myocardial tagging by cardiovascular magnetic resonance: evolution of techniques--pulse sequences, analysis algorithms, and applications.

Authors:  El-Sayed H Ibrahim
Journal:  J Cardiovasc Magn Reson       Date:  2011-07-28       Impact factor: 5.364

9.  Deformation analysis of 3D tagged cardiac images using an optical flow method.

Authors:  Chun Xu; James J Pilla; Gamaliel Isaac; Joseph H Gorman; Aaron S Blom; Robert C Gorman; Zhou Ling; Lawrence Dougherty
Journal:  J Cardiovasc Magn Reson       Date:  2010-03-30       Impact factor: 5.364

Review 10.  Myocardial tissue tagging with cardiovascular magnetic resonance.

Authors:  Monda L Shehata; Susan Cheng; Nael F Osman; David A Bluemke; João A C Lima
Journal:  J Cardiovasc Magn Reson       Date:  2009-12-21       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.